From d4ddbf954bbe7cfbb3906ed639bdf88b3e14db54 Mon Sep 17 00:00:00 2001 From: David Schroeder Date: Sun, 16 Jul 2023 22:35:53 -0500 Subject: [PATCH] update --- defaults.inc | 2 +- inc/certs.inc | 10 +++++----- nodemgmt-scripts.sh | 4 ++-- run.sh | 5 ++--- 4 files changed, 10 insertions(+), 11 deletions(-) diff --git a/defaults.inc b/defaults.inc index 44e4f377..a3a89c42 100755 --- a/defaults.inc +++ b/defaults.inc @@ -165,7 +165,7 @@ NM_BACKUP_ITEMS['fail2ban']=/etc/fail2ban GET-CHECKCERT-DOMAINS(){ declare -A CHECKCERT_DOMAINS IFS=$'\n' - for LINE in `egrep -v '(^#|^$)' ${NM_FOLDER}/ssl-domain-checks.conf`; do + for LINE in `egrep -v '(^#|^$)' ${NM_FOLDER}/conf/ssl-domain-checks.conf`; do HOST=${LINE%% *} PORT=${LINE#* } IFS=" " diff --git a/inc/certs.inc b/inc/certs.inc index e06fd3db..a4d722ed 100755 --- a/inc/certs.inc +++ b/inc/certs.inc @@ -182,7 +182,7 @@ LISTCERTS(){ declare -i cw; declare -i spc1; declare -i c declare -A CHECKCERT_DOMAINS IFS=$'\n' - for LINE in `egrep -v '(^#|^$)' ${NM_FOLDER}/ssl-domain-checks.conf`; do + for LINE in `egrep -v '(^#|^$)' ${NM_FOLDER}/conf/ssl-domain-checks.conf`; do HOST=${LINE%% *} PORT=${LINE#* } IFS=" " @@ -261,7 +261,7 @@ LISTCERTS_NPM(){ declare -i cw; declare -i spc1; declare -i c declare -A CHECKCERT_DOMAINS IFS=$'\n' - for LINE in `egrep -v '(^#|^$)' ${NM_FOLDER}/ssl-domain-checks.conf`; do + for LINE in `egrep -v '(^#|^$)' ${NM_FOLDER}/conf/ssl-domain-checks.conf`; do HOST=${LINE%% *} PORT=${LINE#* } IFS=" " @@ -395,13 +395,13 @@ CHECK_NPMCERTS(){ CHECK-CERTS(){ if [ "${1}" == "check" ]; then rm -f ${NM_FOLDER}/ssl-cert-check.lastrun - ${NM_FOLDER}/ssl-cert-check/ssl-cert-check -f ${NM_FOLDER}/ssl-domain-checks.conf > ${NM_FOLDER}/ssl-cert-check.lastrun + ${NM_FOLDER}/ssl-cert-check/ssl-cert-check -f ${NM_FOLDER}/conf/ssl-domain-checks.conf > ${NM_FOLDER}/ssl-cert-check.lastrun SSLLOG="$(cat ${NM_FOLDER}/ssl-cert-check.lastrun)" SENDNOTICE "SSL Certs Check" "SSL Certs Check\n$SSLLOG" else - # ${NM_FOLDER}/ssl-cert-check/ssl-cert-check -f ${NM_FOLDER}/ssl-domain-checks.conf + # ${NM_FOLDER}/ssl-cert-check/ssl-cert-check -f ${NM_FOLDER}/conf/ssl-domain-checks.conf IFS=$'\n' - for LINE in `egrep -v '(^#|^$)' ${NM_FOLDER}/ssl-domain-checks.conf`; do + for LINE in `egrep -v '(^#|^$)' ${NM_FOLDER}/conf/ssl-domain-checks.conf`; do HOST=${LINE%% *} PORT=${LINE#* } CERTINFO=$(${NM_FOLDER}/ssl-cert-check/ssl-cert-check -p ${PORT} -s ${HOST} -N) diff --git a/nodemgmt-scripts.sh b/nodemgmt-scripts.sh index 64e039c7..1b3b5bb3 100755 --- a/nodemgmt-scripts.sh +++ b/nodemgmt-scripts.sh @@ -358,7 +358,7 @@ NODEUPDATE() { echo -en " ~ ${idsCL[LightCyan]}NodeMGMT${idsCL[Default]} : " if ! ${NCMD} command -v nodemgmt > /dev/null; then ${NCMD} "bash <(curl -sL https://go.scity.us/install-nodemgmt)" >/dev/null 2>&1 - ssh -tq root@${nmip} rsync -az ${NM_FOLDER}/conf/defaults.local.inc root@${nip}:${NM_FOLDER}/ >/dev/null 2>&1 + ssh -tq root@${nmip} rsync -az ${NM_FOLDER}/conf/defaults.local.inc ${NM_FOLDER}/conf/ssl-domain-checks.conf root@${nip}:${NM_FOLDER}/ >/dev/null 2>&1 echo -e "${idsCL[Green]}Installed & Synced${idsCL[Default]}" else ${NCMD} "nodemgmt update q" @@ -375,7 +375,7 @@ NODEUPDATE() { else echo -en " ~ ${idsCL[LightCyan]}Sync Defaults${idsCL[Default]} : " if ssh -tq root@${nip} [[ ! -f ${NM_FOLDER}/conf/defaults.local.inc ]] || [ ${nmdiv} -ne $(ssh -tq root@${nip} ls -l --time-style=+%s ${NM_FOLDER}/conf/defaults.local.inc | cut -d ' ' -f 6) ]; then - ssh -tq root@${nmip} rsync -az ${NM_FOLDER}/conf/defaults.local.inc ${NM_FOLDER}/ssl-domain-checks.conf root@${nip}:${NM_FOLDER}/ >/dev/null 2>&1 + ssh -tq root@${nmip} rsync -az ${NM_FOLDER}/conf/defaults.local.inc ${NM_FOLDER}/conf/ssl-domain-checks.conf root@${nip}:${NM_FOLDER}/ >/dev/null 2>&1 echo -e "${idsCL[Green]}NodeMgmt Defaults File Synced${idsCL[Default]}" else echo -e "${idsCL[Green]}NodeMgmt Defaults File Already Synced${idsCL[Default]}" diff --git a/run.sh b/run.sh index c7efe9a9..8fcf3e97 100755 --- a/run.sh +++ b/run.sh @@ -1,9 +1,8 @@ #!/usr/bin/env bash # NodeMgmt Loader -if [ -f /opt/idssys/settings/nodemgmt.conf ]; then - mv /opt/idssys/settings/nodemgmt.conf /opt/idssys/nodemgmt/conf/settings.conf -fi +[ -f /opt/idssys/nodemgmt/settings.conf ] && mv /opt/idssys/nodemgmt/settings.conf /opt/idssys/nodemgmt/conf/settings.conf +[ -f /opt/idssys/nodemgmt/defaults.local.inc ] && mv /opt/idssys/nodemgmt/defaults.local.inc /opt/idssys/nodemgmt/conf/defaults.local.inc source /opt/idssys/defaults/colors.inc source /opt/idssys/defaults/default.inc