diff --git a/powerwall.sh b/powerwall.sh index bbf1521a..21f596ca 100755 --- a/powerwall.sh +++ b/powerwall.sh @@ -406,12 +406,13 @@ Previous Temp: ${last_temp[${SENSOR}]}${GAUGESH}" # iDS-vMS-Offsite Fan Issue Workaround if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ]; then - # vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${vHOSTiDRACIP} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.2 -O vq) - # FanSpeed=`echo "scale=2; ${vHOSTFAN}/21200" | bc`; FanSpeed=`echo "scale=0; ${FanSpeed}*100" | bc | sed -e 's/.00//g'` - vHOSTFAN=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${SENSORa}]} -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1) + vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${vHOSTiDRACIP} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.2 -O vq) + # vHOSTFAN=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${SENSORa}]} -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1) if [ "${vHOSTFAN}" != "" ]; then - FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g') - if [ ${FanSpeed} -ne 30 ]; then + FanSpeed=`echo "scale=2; ${vHOSTFAN}/21200" | bc`; FanSpeed=`echo "scale=0; ${FanSpeed}*100" | bc | sed -e 's/.00//g'` + # FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g') + if [ ${FanSpeed} -lt 26 ] || [ ${FanSpeed} -gt 34 ]; then + # if [ ${FanSpeed} -ne 30 ]; then SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} Fan Issue" "Settings fans back to normal 30%25" ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00 >/dev/null 2>&1 ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0x1E >/dev/null 2>&1