#!/usr/bin/env bash
|
#!/usr/bin/env bash
|
||||||
|
|
||||||
PW_VERS='2.12.21-09262025'
|
PW_VERS='2.13.1-02202026'
|
||||||
|
|
||||||
noheader=' update service dailytemp confsync -r -report test '
|
noheader=' update service dailytemp confsync -r -report test '
|
||||||
|
|
||||||
|
|||||||
@@ -135,7 +135,8 @@ CHECKPOWER(){
|
|||||||
BATTA_disp="${idsCL[LightRed]}`IDS_NUMBER_FORMAT ${BATTA}`'A ${idsCL[LightCyan]}- Discharging"
|
BATTA_disp="${idsCL[LightRed]}`IDS_NUMBER_FORMAT ${BATTA}`'A ${idsCL[LightCyan]}- Discharging"
|
||||||
fi
|
fi
|
||||||
fi
|
fi
|
||||||
# if [ "$(CHECK_HOST ${PW_UPS_IP})" != "false" ]; then
|
# if [ "$(CHECK_HOST ${PW_UPS_IP})" != "false" ]; then
|
||||||
|
if [ "xxx" == "false" ]; then
|
||||||
SVRRM_VOLTIN=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.2.2.1.3.1.1 | sed 's/.*: //')
|
SVRRM_VOLTIN=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.2.2.1.3.1.1 | sed 's/.*: //')
|
||||||
SVRRM_VOLTIN=`echo "scale=2; ${SVRRM_VOLTIN}/10" | tr -d $'\r' | bc`
|
SVRRM_VOLTIN=`echo "scale=2; ${SVRRM_VOLTIN}/10" | tr -d $'\r' | bc`
|
||||||
SVRRM_VOLTOUT=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.3.2.1.2.1.1 | sed 's/.*: //')
|
SVRRM_VOLTOUT=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.3.2.1.2.1.1 | sed 's/.*: //')
|
||||||
@@ -158,7 +159,16 @@ CHECKPOWER(){
|
|||||||
|
|
||||||
SVRRM_AMP_WAC=$(echo "scale=2; ${SVRRM_AMP}+${AIRCON_AMP}" | tr -d $'\r' | bc -l)
|
SVRRM_AMP_WAC=$(echo "scale=2; ${SVRRM_AMP}+${AIRCON_AMP}" | tr -d $'\r' | bc -l)
|
||||||
SVRRM_WATT_WAC=$(echo "scale=2; ${SVRRM_WATT}+${AIRCON_WATT}" | tr -d $'\r' | bc -l)
|
SVRRM_WATT_WAC=$(echo "scale=2; ${SVRRM_WATT}+${AIRCON_WATT}" | tr -d $'\r' | bc -l)
|
||||||
# fi
|
|
||||||
|
else
|
||||||
|
|
||||||
|
SVRRM_VOLTIN=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.1.15 | sed 's/.*: //')
|
||||||
|
SVRRM_WATT=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.1.16 | sed 's/.*: //')
|
||||||
|
SVRRM_AMP=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.2.3.1.1.2.1 | sed 's/.*: //')
|
||||||
|
SVRRM_AMP=`echo "scale=2; ${SVRRM_AMP}/10" | tr -d $'\r' | bc`
|
||||||
|
|
||||||
|
|
||||||
|
fi
|
||||||
#
|
#
|
||||||
# if [ "$(CHECK_HOST ${PW_APCPDU_IP})" != "false" ]; then
|
# if [ "$(CHECK_HOST ${PW_APCPDU_IP})" != "false" ]; then
|
||||||
APCPDU_AMP=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.2.3.1.1.2.1 | sed 's/.*: //')
|
APCPDU_AMP=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.2.3.1.1.2.1 | sed 's/.*: //')
|
||||||
@@ -172,7 +182,7 @@ CHECKPOWER(){
|
|||||||
NETRK_WATT=`echo "scale=2; ${SVRRM_WATT}-${APCPDU_WATT}" | tr -d $'\r' | bc`
|
NETRK_WATT=`echo "scale=2; ${SVRRM_WATT}-${APCPDU_WATT}" | tr -d $'\r' | bc`
|
||||||
NETRK_WATT2=`echo "scale=2; ${SVRRM_WATT}-${APCPDU_WATT2}" | tr -d $'\r' | bc`
|
NETRK_WATT2=`echo "scale=2; ${SVRRM_WATT}-${APCPDU_WATT2}" | tr -d $'\r' | bc`
|
||||||
fi
|
fi
|
||||||
VOLT_DROP=`echo "scale=1; ${OUTPUTV2}-${SVRRM_VOLTIN}" | tr -d $'\r' | bc`
|
# VOLT_DROP=`echo "scale=1; ${OUTPUTV2}-${SVRRM_VOLTIN}" | tr -d $'\r' | bc`
|
||||||
fi
|
fi
|
||||||
|
|
||||||
|
|
||||||
@@ -200,8 +210,8 @@ CHECKPOWER(){
|
|||||||
echo -e "${idsCL[White]}Battery Amps Chg/DChg ${idsCL[Default]}: ${BATTA_disp}${idsCL[Default]}"
|
echo -e "${idsCL[White]}Battery Amps Chg/DChg ${idsCL[Default]}: ${BATTA_disp}${idsCL[Default]}"
|
||||||
echo
|
echo
|
||||||
echo -e "${idsCL[White]}Server Room Voltage IN ${idsCL[Default]}: ${idsCL[Green]}${SVRRM_VOLTIN}'V${idsCL[Default]}"
|
echo -e "${idsCL[White]}Server Room Voltage IN ${idsCL[Default]}: ${idsCL[Green]}${SVRRM_VOLTIN}'V${idsCL[Default]}"
|
||||||
echo -e "${idsCL[White]}Server Room Voltage OUT ${idsCL[Default]}: ${idsCL[Green]}${SVRRM_VOLTOUT}'V${idsCL[Default]}"
|
# echo -e "${idsCL[White]}Server Room Voltage OUT ${idsCL[Default]}: ${idsCL[Green]}${SVRRM_VOLTOUT}'V${idsCL[Default]}"
|
||||||
[ ${REPORT} -eq 0 ] && echo -e "${idsCL[White]}Voltage Drop ${idsCL[Default]}: ${idsCL[LightRed]}${VOLT_DROP}'V${idsCL[Default]}"
|
# [ ${REPORT} -eq 0 ] && echo -e "${idsCL[White]}Voltage Drop ${idsCL[Default]}: ${idsCL[LightRed]}${VOLT_DROP}'V${idsCL[Default]}"
|
||||||
|
|
||||||
# echo
|
# echo
|
||||||
DIVIDER . lightCyan ${PRI_WIDTH}
|
DIVIDER . lightCyan ${PRI_WIDTH}
|
||||||
|
|||||||