update
This commit is contained in:
@@ -1,6 +1,6 @@
|
|||||||
#!/usr/bin/env bash
|
#!/usr/bin/env bash
|
||||||
|
|
||||||
VERS='2.3.4-10222023'
|
VERS='2.3.6-10222023'
|
||||||
|
|
||||||
noheader=' update service dailytemp '
|
noheader=' update service dailytemp '
|
||||||
|
|
||||||
|
|||||||
16
powerwall.sh
16
powerwall.sh
@@ -215,8 +215,6 @@ CHECKTEMP_SERVICE(){
|
|||||||
ssh root@${PW_RACADM_ACCESS} "ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P '${PW_ESXI_PASS}' raw 0x30 0x30 0x01 0x00" >/dev/null 2>&1
|
ssh root@${PW_RACADM_ACCESS} "ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P '${PW_ESXI_PASS}' raw 0x30 0x30 0x01 0x00" >/dev/null 2>&1
|
||||||
ssh root@${PW_RACADM_ACCESS} "ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P '${PW_ESXI_PASS}' raw 0x30 0x30 0x02 0xff 0x1E" >/dev/null 2>&1
|
ssh root@${PW_RACADM_ACCESS} "ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P '${PW_ESXI_PASS}' raw 0x30 0x30 0x02 0xff 0x1E" >/dev/null 2>&1
|
||||||
fi
|
fi
|
||||||
QRY="USE servermonitor; INSERT INTO sensor_data (\`sensorid\`, \`date\`, \`speed\`) VALUES ('14','$(date +'%Y-%m-%d %H:%M:%S')','${FanSpeed}')"
|
|
||||||
${mysql_conn} -e "${QRY}"
|
|
||||||
fi
|
fi
|
||||||
|
|
||||||
else
|
else
|
||||||
@@ -365,6 +363,17 @@ Previous Temp: ${last_temp[${SENSOR}]}'F"
|
|||||||
fi
|
fi
|
||||||
rm -f ${PW_TMPFOLDER}/temp.*
|
rm -f ${PW_TMPFOLDER}/temp.*
|
||||||
last_temp[${SENSOR}]=1
|
last_temp[${SENSOR}]=1
|
||||||
|
|
||||||
|
# iDS-vMS-Offsite Fan Issue Workaround
|
||||||
|
if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ]; then
|
||||||
|
vHOSTFAN=$(ssh root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${SENSORa}]} -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1)
|
||||||
|
FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g')
|
||||||
|
if [ ${FanSpeed} -ne 80 ]; then
|
||||||
|
SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} Fan Issue" "Workaround commands sent to set the Fans at 30(percent)" 1
|
||||||
|
ssh root@${PW_RACADM_ACCESS} "ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P '${PW_ESXI_PASS}' raw 0x30 0x30 0x01 0x00" >/dev/null 2>&1
|
||||||
|
ssh root@${PW_RACADM_ACCESS} "ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P '${PW_ESXI_PASS}' raw 0x30 0x30 0x02 0xff 0x50" >/dev/null 2>&1
|
||||||
|
fi
|
||||||
|
fi
|
||||||
fi
|
fi
|
||||||
|
|
||||||
[ -f ${PW_TMPFOLDER}/${SENSOR}.insert ] && lastinsert=$(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/${SENSOR}.insert)) || lastinsert=100000
|
[ -f ${PW_TMPFOLDER}/${SENSOR}.insert ] && lastinsert=$(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/${SENSOR}.insert)) || lastinsert=100000
|
||||||
@@ -383,6 +392,9 @@ Previous Temp: ${last_temp[${SENSOR}]}'F"
|
|||||||
entityid=${entityid[1]}
|
entityid=${entityid[1]}
|
||||||
|
|
||||||
QRY="USE servermonitor; INSERT INTO sensor_data (\`sensorid\`, \`entity\`, \`date\`, \`temp\`) VALUES ('${PW_SENSOR_ID[${SENSORa}]}','${entityid}','${datetime}','${temp_f}')"
|
QRY="USE servermonitor; INSERT INTO sensor_data (\`sensorid\`, \`entity\`, \`date\`, \`temp\`) VALUES ('${PW_SENSOR_ID[${SENSORa}]}','${entityid}','${datetime}','${temp_f}')"
|
||||||
|
if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ]; then
|
||||||
|
QRY="${QRY}; INSERT INTO sensor_data (\`sensorid\`, \`date\`, \`speed\`) VALUES ('14','${datetime}','${FanSpeed}')"
|
||||||
|
fi
|
||||||
elif [ "${temp_h}" != "" ]; then
|
elif [ "${temp_h}" != "" ]; then
|
||||||
QRY="USE servermonitor; INSERT INTO sensor_data (\`sensorid\`, \`date\`, \`temp\`, \`hum\`) VALUES ('${PW_SENSOR_ID[${SENSORa}]}','${datetime}','${temp_f}','${temp_h}')"
|
QRY="USE servermonitor; INSERT INTO sensor_data (\`sensorid\`, \`date\`, \`temp\`, \`hum\`) VALUES ('${PW_SENSOR_ID[${SENSORa}]}','${datetime}','${temp_f}','${temp_h}')"
|
||||||
else
|
else
|
||||||
|
|||||||
Reference in New Issue