update
This commit is contained in:
@@ -1,6 +1,6 @@
|
|||||||
#!/usr/bin/env bash
|
#!/usr/bin/env bash
|
||||||
|
|
||||||
PW_VERS='2.12.6-07192025'
|
PW_VERS='2.12.8-07192025'
|
||||||
|
|
||||||
noheader=' update service dailytemp confsync -r -report test '
|
noheader=' update service dailytemp confsync -r -report test '
|
||||||
|
|
||||||
|
|||||||
@@ -482,7 +482,7 @@ CHECKPOWER(){
|
|||||||
OFFSITE_BATT_VOLT=$(echo "${upsinfo}" | grep 'battery.voltage:' | sed 's/.*: //' | tr -d $'\r')
|
OFFSITE_BATT_VOLT=$(echo "${upsinfo}" | grep 'battery.voltage:' | sed 's/.*: //' | tr -d $'\r')
|
||||||
OFFSITE_BATT_CAP=$(echo "${upsinfo}" | grep 'battery.charge:' | sed 's/.*: //' | tr -d $'\r')
|
OFFSITE_BATT_CAP=$(echo "${upsinfo}" | grep 'battery.charge:' | sed 's/.*: //' | tr -d $'\r')
|
||||||
|
|
||||||
POWER_STRIP_DATA=$(kasa --type strip --json --host 10.2.1.234 energy)
|
POWER_STRIP_DATA=$(kasa --type strip --json --host ${PW_OFFSITE_POWER_STRIP} energy)
|
||||||
OFFSITE_WATTS=$(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.power_mw')/1000" | tr -d $'\r' | bc -l)
|
OFFSITE_WATTS=$(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.power_mw')/1000" | tr -d $'\r' | bc -l)
|
||||||
OFFSITE_AMPS=$(echo $(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.current_ma')/1000" | tr -d $'\r' | bc -l))
|
OFFSITE_AMPS=$(echo $(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.current_ma')/1000" | tr -d $'\r' | bc -l))
|
||||||
OFFSITE_VOLTS=$(echo $(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.voltage_mv')/1000" | tr -d $'\r' | bc -l))
|
OFFSITE_VOLTS=$(echo $(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.voltage_mv')/1000" | tr -d $'\r' | bc -l))
|
||||||
@@ -1049,7 +1049,7 @@ OFFSITE_CHECKPOWER_SERVICE(){
|
|||||||
OFFSITE_BATT_RUNTIME=`echo "scale=2; ${OFFSITE_BATT_RUNTIME}/60" | tr -d $'\r' | bc`
|
OFFSITE_BATT_RUNTIME=`echo "scale=2; ${OFFSITE_BATT_RUNTIME}/60" | tr -d $'\r' | bc`
|
||||||
OFFSITE_BATT_CAP=$(echo "${upsinfo}" | grep 'battery.charge:' | sed 's/.*: //' | tr -d $'\r')
|
OFFSITE_BATT_CAP=$(echo "${upsinfo}" | grep 'battery.charge:' | sed 's/.*: //' | tr -d $'\r')
|
||||||
|
|
||||||
POWER_STRIP_DATA=$(kasa --type strip --json --host 10.2.1.234 energy)
|
POWER_STRIP_DATA=$(kasa --type strip --json --host ${PW_OFFSITE_POWER_STRIP} energy)
|
||||||
OFFSITE_WATTS=$(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.power_mw')/1000" | tr -d $'\r' | bc -l)
|
OFFSITE_WATTS=$(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.power_mw')/1000" | tr -d $'\r' | bc -l)
|
||||||
|
|
||||||
|
|
||||||
@@ -1343,7 +1343,7 @@ POWERLOGGER_SERVICE(){
|
|||||||
OFFSITE_WATTS=`echo "scale=2; ${OFFSITE_LOAD}*$(echo "${upsinfo}" | grep 'ups.realpower.nominal:' | sed 's/.*: //')" | tr -d $'\r' | bc`
|
OFFSITE_WATTS=`echo "scale=2; ${OFFSITE_LOAD}*$(echo "${upsinfo}" | grep 'ups.realpower.nominal:' | sed 's/.*: //')" | tr -d $'\r' | bc`
|
||||||
OFFSITE_AMPS=`echo "scale=2; ${OFFSITE_WATTS}/${OFFSITE_VOLTOUT}" | tr -d $'\r' | bc`
|
OFFSITE_AMPS=`echo "scale=2; ${OFFSITE_WATTS}/${OFFSITE_VOLTOUT}" | tr -d $'\r' | bc`
|
||||||
|
|
||||||
POWER_STRIP_DATA=$(kasa --type strip --json --host 10.2.1.234 energy)
|
POWER_STRIP_DATA=$(kasa --type strip --json --host ${PW_OFFSITE_POWER_STRIP} energy)
|
||||||
OFFSITE_STRIP_WATTS=$(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.power_mw')/1000" | tr -d $'\r' | bc -l)
|
OFFSITE_STRIP_WATTS=$(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.power_mw')/1000" | tr -d $'\r' | bc -l)
|
||||||
OFFSITE_STRIP_AMPS=$(echo $(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.current_ma')/1000" | tr -d $'\r' | bc -l))
|
OFFSITE_STRIP_AMPS=$(echo $(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.current_ma')/1000" | tr -d $'\r' | bc -l))
|
||||||
OFFSITE_STRIP_VOLTS=$(echo $(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.voltage_mv')/1000" | tr -d $'\r' | bc -l))
|
OFFSITE_STRIP_VOLTS=$(echo $(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.voltage_mv')/1000" | tr -d $'\r' | bc -l))
|
||||||
|
|||||||
Reference in New Issue
Block a user