This commit is contained in:
2025-06-01 15:54:25 -05:00
parent 5c38710449
commit 4493334866
3 changed files with 28 additions and 29 deletions

View File

@@ -182,7 +182,7 @@ CHECKPOWER(){
echo
fi
echo -en "${idsCL[White]}Inverter Input Volts ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${INPUTV}`'V"
[ "${TEST_INPUTACV}" != "" ] && echo -e " ${idsCL[Yellow]}***TEST MODE***" || echo ""
[ ${TESTMODE} -eq 1 ] && echo -e " ${idsCL[Yellow]}***TEST MODE***" || echo ""
echo -e "${idsCL[White]}Inverter Input Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${INPUTA}`'A"
if [ ${REPORT} -eq 0 ]; then
echo
@@ -790,9 +790,7 @@ CHECKPOWER_SERVICE(){
start=$(date +%s)
log_start=$(date "+%Y-%m-%d %H:%M:%S")
source ${PW_FOLDER}/defaults.inc
([ "${TEST_INPUTACV}" != "" ] || [ "${TEST_BATTVOLT}" != "" ]) && TESTMODE=1 || TESTMODE=0
if [[ "${IP}" != "10.6.1"* ]]; then
INVSTATSINFO=$(curl -m 3 -s "http://${PW_INVERTER_IP}/stats.json")
@@ -1003,11 +1001,11 @@ OFFSITE_CHECKPOWER_SERVICE(){
PW_OFFSITE_SHUTDOWNSERVERS_AT_BATTCAP=98 #percent
PW_OFFSITE_SHUTDOWNSERVERS_AFTER=1 #minutes
PW_OFFSITE_WAIT_TO_POWER_SERVERS=1 #minutes
TESTMODE="### TEST MODE ACTIVE ###
TESTMSG="### TEST MODE ACTIVE ###
"
else
TESTMODE=""
TESTMSG=""
fi
# upsinfo=$(upsc offsite-ups)
@@ -1043,7 +1041,7 @@ OFFSITE_CHECKPOWER_SERVICE(){
fi
SENDNOTICE2(){
MESSAGE="${TESTMODE}${2}
MESSAGE="${TESTMSG}${2}
BATTERY CHARGE: ${OFFSITE_BATT_CAP}'%
BATT RUNTIME: ${OFFSITE_BATT_RUNTIME}'mins
@@ -1484,7 +1482,7 @@ HOSTPOWER(){
MSG="Powering ON the SAS Enclosure"
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
echo -en "\n${idsCL[LightCyan]}${MSG}${MSG_SPC}: "
if [ "${TEST}" != "true" ]; then
if [ ${TESTMODE} -eq 0 ]; then
current_status=$(snmpwalk -t 3 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.14 | sed 's/.*: //')
if [ "${current_status}" != "" ] && [ "${current_status}" != "1" ]; then
run=$(snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.14 i 1 >/dev/null 2>&1)
@@ -1498,7 +1496,7 @@ HOSTPOWER(){
fi
fi
if [ "${TEST}" != "true" ]; then
if [ ${TESTMODE} -eq 0 ]; then
current_status=$(ipmitool -I lanplus -H ${idracip} -U ${PW_ESXI_USER} -P "${ESXI_PASS}" chassis power status | grep "Power is ${2,,}")
if [ "${current_status}" = "" ]; then
echo -e "${idsCL[Green]}"
@@ -1516,7 +1514,7 @@ HOSTPOWER(){
MSG="Powering OFF the SAS Enclosure"
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: "
if [ "${TEST}" != "true" ]; then
if [ ${TESTMODE} -eq 0 ]; then
if [ "$(CHECK_HOST ${PW_ISCSI_PRI_HOST})" = "false" ]; then
run=$(snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.14 i 2 >/dev/null 2>&1)
sleep 3s