Update temp.inc.sh
This commit is contained in:
@@ -557,6 +557,7 @@ CHECKTEMP(){
|
||||
fi
|
||||
|
||||
if [ "${TTYPE}" == "fans" ]; then
|
||||
if [[ "${PW_ESXI_FANSPEEDCONTROL_HOSTS}" = *"${PW_HOST_IDRACS[${SENSOR}]}"* ]]; then
|
||||
if [ -f ${PW_TMPFOLDER}/.lastfancheck/${cSENSOR}.gl ]; then
|
||||
FSC="${idsCL[LightGreen]}"
|
||||
elif [ -f ${PW_TMPFOLDER}/.lastfancheck/${cSENSOR}.set ]; then
|
||||
@@ -581,6 +582,10 @@ CHECKTEMP(){
|
||||
else
|
||||
echo -e "${idsCL[Default]}"
|
||||
fi
|
||||
|
||||
else
|
||||
echo -e " Fans are not managed for this host"
|
||||
fi
|
||||
fi
|
||||
fi
|
||||
((t++))
|
||||
@@ -849,7 +854,8 @@ CHECKTEMP_SERVICE_RUNSENSOR(){
|
||||
t=1
|
||||
|
||||
####### Grab Fan Speeds #######
|
||||
if [ ! -f ${PW_TMPFOLDER}/${SENSORa}.down ] && ([ ! -f ${PW_TMPFOLDER}/.lastfancheck/${SENSORa} ] || [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/.lastfancheck/${SENSORa})) -ge 60 ]); then
|
||||
# if [ ! -f ${PW_TMPFOLDER}/${SENSORa}.down ] && ([ ! -f ${PW_TMPFOLDER}/.lastfancheck/${SENSORa} ] || [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/.lastfancheck/${SENSORa})) -ge 60 ]); then
|
||||
if [ ! -f ${PW_TMPFOLDER}/${SENSORa}.down ]; then
|
||||
# vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSORa}]} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.3 -O vq)
|
||||
vHOSTFAN=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${SENSORa}]} -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan3" 2>&1)
|
||||
if [ "${vHOSTFAN}" != "" ]; then
|
||||
@@ -1006,12 +1012,13 @@ CHECKTEMP_SERVICE_RUNSENSOR(){
|
||||
|
||||
##### ESXI FAN CONTROL #####
|
||||
elif [[ "${PW_ESXI_FANSPEEDCONTROL_HOSTS}" = *"${PW_HOST_IDRACS[${SENSORa}]}"* ]] && [[ "${vSENSOR}" = *"Exhaust"* ]] && [ "${FanSpeed}" != "" ]; then
|
||||
if [ ! -f ${PW_TMPFOLDER}/.lastfancheck/${SENSORa}.chkset ] || [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/.lastfancheck/${SENSORa}.chkset)) -ge 300 ]; then
|
||||
|
||||
if [ ! -f ${PW_TMPFOLDER}/.lastfancheck/${SENSORa}.set ]; then
|
||||
NEW_FanSpeed=$(GET_DEFAULT_FANSPEED ${SENSORa} ${FanSpeed})
|
||||
SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} FanSpeed Control" "Re-enabling Host Fan control to Powerwall. Setting fans back to defaults: ${NEW_FanSpeed}%"
|
||||
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00 >/dev/null 2>&1
|
||||
[ "${SENSORa}" == "iDS-vMS-Host7" ] && ipmitool -I lanplus -H 10.10.2.26 -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00 >/dev/null 2>&1
|
||||
[ "${SENSORa}" == "iDS-vMS-Host7" ] && [[ "${PW_ESXI_FANSPEEDCONTROL_HOSTS}" = *"10.10.2.26"* ]] && ipmitool -I lanplus -H 10.10.2.26 -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00 >/dev/null 2>&1
|
||||
SET_ESXI_FANSPEED ${NEW_FanSpeed} ${SENSORa} e >/dev/null 2>&1 &
|
||||
fi
|
||||
|
||||
@@ -1020,7 +1027,7 @@ CHECKTEMP_SERVICE_RUNSENSOR(){
|
||||
if [ ! -f ${PW_TMPFOLDER}/.lastfancheck/${SENSORa}.gl ] && [ -f ${PW_TMPFOLDER}/.lastfancheck/${SENSORa}.set ] && [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/.lastfancheck/${SENSORa}.set)) -ge 3600 ]; then
|
||||
# SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} FAN CONTROL" "Goldilock Zone Found at ${FanSpeed}%"
|
||||
echo "${FanSpeed}" >| ${PW_TMPFOLDER}/.lastfancheck/${SENSORa}.gl
|
||||
[ "${SENSORa}" == "iDS-vMS-Host7" ] && [ ! -f ${PW_TMPFOLDER}/iDS-vMS-Host6.down ] && echo "${FanSpeed}" >| ${PW_TMPFOLDER}/.lastfancheck/iDS-vMS-Host6.gl
|
||||
[ "${SENSORa}" == "iDS-vMS-Host7" ] && [[ "${PW_ESXI_FANSPEEDCONTROL_HOSTS}" = *"10.10.2.26"* ]] && [ ! -f ${PW_TMPFOLDER}/iDS-vMS-Host6.down ] && echo "${FanSpeed}" >| ${PW_TMPFOLDER}/.lastfancheck/iDS-vMS-Host6.gl
|
||||
echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${FanSpeed}% - ${SENSORa} - Goldilock Zone Found (1HR)" >> ${logtemp}
|
||||
echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${FanSpeed}% - ${SENSORa} - Goldilock Zone Found (1HR)" >> ${PW_LOGFOLDER}/esxi-fanspeeds.log
|
||||
|
||||
@@ -1071,12 +1078,15 @@ CHECKTEMP_SERVICE_RUNSENSOR(){
|
||||
fi
|
||||
fi
|
||||
fi
|
||||
|
||||
touch ${PW_TMPFOLDER}/.lastfancheck/${SENSORa}.chkset
|
||||
fi
|
||||
elif [[ "${PW_ESXI_FANSPEEDCONTROL_HOSTS}" != *"${PW_HOST_IDRACS[${SENSORa}]}"* ]] && [[ "${vSENSOR}" = *"Exhaust"* ]]; then
|
||||
if [ -f ${PW_TMPFOLDER}/.lastfancheck/${SENSORa}.set ]; then
|
||||
SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} FanSpeed Control" "Resetting Fans back to being Host Controlled"
|
||||
rm -f ${PW_TMPFOLDER}/.lastfancheck/${SENSORa}*
|
||||
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x01 >/dev/null 2>&1
|
||||
if [ "${SENSORa}" == "iDS-vMS-Host7" ]; then
|
||||
if [ "${SENSORa}" == "iDS-vMS-Host7" ] && [[ "${PW_ESXI_FANSPEEDCONTROL_HOSTS}" = *"10.10.2.26"* ]]; then
|
||||
SENDNOTICE "10.10.2.26 FanSpeed Control" "Resetting Fans back to being Host Controlled"
|
||||
rm -f ${PW_TMPFOLDER}/.lastfancheck/iDS-vMS-Host6*
|
||||
ipmitool -I lanplus -H 10.10.2.26 -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x01 >/dev/null 2>&1
|
||||
@@ -1088,6 +1098,7 @@ CHECKTEMP_SERVICE_RUNSENSOR(){
|
||||
fi
|
||||
fi
|
||||
|
||||
|
||||
if [[ "${SENSORa}" != *"-Usage"* ]] && [[ "${SENSORa}" != *"FAN"* ]] && (( $(bc <<< "${temp_f} < ${temp_warn}") )); then
|
||||
if (( $(bc <<< "${last_temp} >= ${temp_warn}") )); then
|
||||
[ -f ${PW_TMPFOLDER}/${SENSORa}.down ] && [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/${SENSORa}.down)) -ge 1800 ] && SENDNOTICE "${SENSOR} BACK TO NORMAL" "NORMAL TEMP: ${temp_f}${GAUGESH}
|
||||
|
||||
Reference in New Issue