update
This commit is contained in:
@@ -1,5 +1,5 @@
|
|||||||
|
|
||||||
VERS='2.4.16-12112023'
|
VERS='2.4.17-12112023'
|
||||||
|
|
||||||
noheader=' update service dailytemp '
|
noheader=' update service dailytemp '
|
||||||
hc_cw=60
|
hc_cw=60
|
||||||
|
|||||||
24
powerwall.sh
24
powerwall.sh
@@ -872,12 +872,18 @@ BATT VOLTAGE: ${BATTVOLT}'volts"
|
|||||||
fi
|
fi
|
||||||
fi
|
fi
|
||||||
if [ ! -f ${PW_TMPFOLDER}/power.ac.good ]; then
|
if [ ! -f ${PW_TMPFOLDER}/power.ac.good ]; then
|
||||||
# if [ -f ${PW_TMPFOLDER}/power.sys.off ]
|
|
||||||
#
|
if [ -f ${PW_TMPFOLDER}/power.sys.off ] || [ -f ${PW_TMPFOLDER}/power.main.off ] || [ -f ${PW_TMPFOLDER}/power.ac.conserve ]
|
||||||
# fi
|
SENDNOTICE "HOSTS POWER" "Power restored! Will wait 3'mins before turning host(s) back on"
|
||||||
|
touch ${PW_TMPFOLDER}/.power.restored
|
||||||
|
fi
|
||||||
|
|
||||||
rm -f ${PW_TMPFOLDER}/power.ac.*
|
rm -f ${PW_TMPFOLDER}/power.ac.*
|
||||||
touch ${PW_TMPFOLDER}/power.ac.good
|
touch ${PW_TMPFOLDER}/power.ac.good
|
||||||
|
|
||||||
|
elif [ -f ${PW_TMPFOLDER}/.power.restored ] && [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/.power.restored)) -ge 300 ]; then
|
||||||
|
HOSTMGMT mainsite -p on >/dev/null 2>&1
|
||||||
|
rm -f ${PW_TMPFOLDER}/.power.restored
|
||||||
fi
|
fi
|
||||||
|
|
||||||
# UPDATE APC-PDU LINE TO LINE VOLTAGE
|
# UPDATE APC-PDU LINE TO LINE VOLTAGE
|
||||||
@@ -1171,12 +1177,14 @@ CHECK_SERVICES(){
|
|||||||
|
|
||||||
SHUTDOWN_MAIN(){
|
SHUTDOWN_MAIN(){
|
||||||
if [ "${1}" == "ServerRoomTH"] || [ "${1}" == "TEMP"]; then
|
if [ "${1}" == "ServerRoomTH"] || [ "${1}" == "TEMP"]; then
|
||||||
SHUTDOWN_SERVERS MAIN ${1}
|
# SHUTDOWN_SERVERS MAIN ${1}
|
||||||
|
HOSTMGMT main -e off >/dev/null 2>&1
|
||||||
reason='Server Room Overheated!'
|
reason='Server Room Overheated!'
|
||||||
sendnotice=true
|
sendnotice=true
|
||||||
|
|
||||||
elif [ "${1}" == "POWER"]; then
|
elif [ "${1}" == "POWER"]; then
|
||||||
SHUTDOWN_SERVERS MAIN ${1}
|
# SHUTDOWN_SERVERS MAIN ${1}
|
||||||
|
HOSTMGMT main -e off >/dev/null 2>&1
|
||||||
reason='Low Power!'
|
reason='Low Power!'
|
||||||
sendnotice=true
|
sendnotice=true
|
||||||
|
|
||||||
@@ -1194,12 +1202,14 @@ ${reason}" 1
|
|||||||
}
|
}
|
||||||
SHUTDOWN_SYS(){
|
SHUTDOWN_SYS(){
|
||||||
if [ "${1}" == "ServerRoomTH"] || [ "${1}" == "TEMP"]; then
|
if [ "${1}" == "ServerRoomTH"] || [ "${1}" == "TEMP"]; then
|
||||||
SHUTDOWN_SERVERS SYS ${1}
|
# SHUTDOWN_SERVERS SYS ${1}
|
||||||
|
HOSTMGMT sys -e off >/dev/null 2>&1
|
||||||
reason='Server Room Overheated!'
|
reason='Server Room Overheated!'
|
||||||
sendnotice=true
|
sendnotice=true
|
||||||
|
|
||||||
elif [ "${1}" == "POWER"]; then
|
elif [ "${1}" == "POWER"]; then
|
||||||
SHUTDOWN_SERVERS SYS ${1}
|
# SHUTDOWN_SERVERS SYS ${1}
|
||||||
|
HOSTMGMT sys -e off >/dev/null 2>&1
|
||||||
reason='Low Power!'
|
reason='Low Power!'
|
||||||
sendnotice=true
|
sendnotice=true
|
||||||
|
|
||||||
|
|||||||