update
This commit is contained in:
@@ -1,6 +1,6 @@
|
|||||||
#!/usr/bin/env bash
|
#!/usr/bin/env bash
|
||||||
|
|
||||||
VERS='2.3.1-10222023'
|
VERS='2.3.3-10222023'
|
||||||
|
|
||||||
noheader=' update service dailytemp '
|
noheader=' update service dailytemp '
|
||||||
|
|
||||||
|
|||||||
30
powerwall.sh
30
powerwall.sh
@@ -288,8 +288,16 @@ CHECKTEMP_SERVICE(){
|
|||||||
last_temp[${SENSOR}]=$temp_f
|
last_temp[${SENSOR}]=$temp_f
|
||||||
echo "($datetime) - ${temp_f}'F - WARNING TEMP - (Difference of ${temp_diff}')" >> ${logtemp}
|
echo "($datetime) - ${temp_f}'F - WARNING TEMP - (Difference of ${temp_diff}')" >> ${logtemp}
|
||||||
|
|
||||||
|
# iDS-vMS-Offsite Fan Issue Workaround
|
||||||
|
if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ]; then
|
||||||
|
vHOSTFAN=$(ssh root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${SENSORa}]} -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1)
|
||||||
|
FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g')
|
||||||
|
if [ ${FanSpeed} -ne 80 ]; then
|
||||||
|
SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} Fan Issue" "Workaround commands sent to set the Fans at 30(percent)" 1
|
||||||
|
ssh root@${PW_RACADM_ACCESS} "ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P '${PW_ESXI_PASS}' raw 0x30 0x30 0x01 0x00" >/dev/null 2>&1
|
||||||
|
ssh root@${PW_RACADM_ACCESS} "ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P '${PW_ESXI_PASS}' raw 0x30 0x30 0x02 0xff 0x50" >/dev/null 2>&1
|
||||||
|
fi
|
||||||
|
fi
|
||||||
fi
|
fi
|
||||||
|
|
||||||
elif [ $(bc -l <<< "$temp_f >= $temp_crit") -eq 1 ] && [ $(bc -l <<< "$temp_f < $temp_crit_sys") -eq 1 ]; then
|
elif [ $(bc -l <<< "$temp_f >= $temp_crit") -eq 1 ] && [ $(bc -l <<< "$temp_f < $temp_crit_sys") -eq 1 ]; then
|
||||||
@@ -303,6 +311,24 @@ CHECKTEMP_SERVICE(){
|
|||||||
SHUTDOWN_MAIN ${SENSOR} &
|
SHUTDOWN_MAIN ${SENSOR} &
|
||||||
echo -e "($datetime) - ${temp_f}'F - Shutting down MAIN servers" >> ${logtemp}
|
echo -e "($datetime) - ${temp_f}'F - Shutting down MAIN servers" >> ${logtemp}
|
||||||
|
|
||||||
|
# iDS-vMS-Offsite Fan Issue Workaround
|
||||||
|
if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ]; then
|
||||||
|
if [ "${TEST}" != "true" ]; then
|
||||||
|
SENDNOTICE "${SENSORa} TEMP CRITICAL" "Host system and VMs shutting down!!" 1
|
||||||
|
|
||||||
|
${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown.ps1 ${PW_HOST_ADDRESSES[${SENSORa}]} >/dev/null 2>&1
|
||||||
|
${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown-verify.ps1 ${PW_HOST_ADDRESSES[${SENSORa}]} >/dev/null 2>&1
|
||||||
|
ssh root@${PW_HOST_ADDRESSES[${SENSORa}]} 'esxcli system maintenanceMode set -e true -t 0' &
|
||||||
|
${PW_FOLDER}/esxi-scripts/vm-shutdown.ps1 ${PW_HOST_ADDRESSES[${SENSORa}]} >/dev/null 2>&1
|
||||||
|
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${PW_HOST_ADDRESSES[${SENSORa}]} >/dev/null 2>&1
|
||||||
|
ssh root@${PW_HOST_ADDRESSES[${SENSORa}]} 'esxcli system shutdown poweroff -d 10 -r "Automated ESXi host shutdown"'
|
||||||
|
ssh root@${PW_HOST_ADDRESSES[${SENSORa}]} 'esxcli system maintenanceMode set -e false -t 0'
|
||||||
|
|
||||||
|
while ping -qw 10 -c3 "${PW_HOST_ADDRESSES[${SENSORa}]}">/dev/null 2>&1; do
|
||||||
|
sleep 1
|
||||||
|
done
|
||||||
|
fi
|
||||||
|
fi
|
||||||
fi
|
fi
|
||||||
elif [ $(bc -l <<< "$temp_f >= $temp_crit_sys") -eq 1 ]; then
|
elif [ $(bc -l <<< "$temp_f >= $temp_crit_sys") -eq 1 ]; then
|
||||||
touch ${PW_TMPFOLDER}/temp.critsys
|
touch ${PW_TMPFOLDER}/temp.critsys
|
||||||
|
|||||||
Reference in New Issue