@@ -95,10 +95,13 @@ CHECKPOWER(){
[ "${TEST_INPUTACV}" != "" ] && echo -e " ${idsCL[Yellow]}***TEST MODE***" || echo "" [ "${TEST_INPUTACV}" != "" ] && echo -e " ${idsCL[Yellow]}***TEST MODE***" || echo ""
echo -e "${idsCL[White]}Inverter Input Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${INPUTA}`'amps" echo -e "${idsCL[White]}Inverter Input Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${INPUTA}`'amps"
echo echo
if [ ${REPORT} -eq 0 ]; then
echo -e "${idsCL[White]}Inverter Output Volts ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OUTPUTV}`'volts / `IDS_NUMBER_FORMAT ${OUTPUTV2}`'volts" echo -e "${idsCL[White]}Inverter Output Volts ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OUTPUTV}`'volts / `IDS_NUMBER_FORMAT ${OUTPUTV2}`'volts"
echo -e "${idsCL[White]}Inverter Output Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OUTPUTA}`'amps / `IDS_NUMBER_FORMAT ${OUTPUTA2}`'amps" echo -e "${idsCL[White]}Inverter Output Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OUTPUTA}`'amps / `IDS_NUMBER_FORMAT ${OUTPUTA2}`'amps"
echo -e "${idsCL[White]}Inverter Output Watts ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OUTPUTW}`'watts" echo -e "${idsCL[White]}Inverter Output Watts ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OUTPUTW}`'watts"
echo echo
fi
echo -en "${idsCL[White]}Battery Voltage ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${BATTV}`'volts ~ `IDS_NUMBER_FORMAT ${BATTLIFE}`%" echo -en "${idsCL[White]}Battery Voltage ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${BATTV}`'volts ~ `IDS_NUMBER_FORMAT ${BATTLIFE}`%"
[ "${TEST_BATTVOLT}" != "" ] && echo -e " ${idsCL[Yellow]}***TEST MODE***" || echo "" [ "${TEST_BATTVOLT}" != "" ] && echo -e " ${idsCL[Yellow]}***TEST MODE***" || echo ""
echo -e "${idsCL[White]}Battery Amps Chg/DChg ${idsCL[Default]}: ${BATTA_disp}${idsCL[Default]}" echo -e "${idsCL[White]}Battery Amps Chg/DChg ${idsCL[Default]}: ${BATTA_disp}${idsCL[Default]}"
@@ -135,7 +138,8 @@ CHECKPOWER(){
VOLT_DROP=`echo "scale=1; ${OUTPUTV2}-${SVRRM_VOLTIN}" | bc` VOLT_DROP=`echo "scale=1; ${OUTPUTV2}-${SVRRM_VOLTIN}" | bc`
fi fi
[ ${REPORT} -eq 0 ] && echo -en "\r\033[K" if [ ${REPORT} -eq 0 ]; then
echo -en "\r\033[K"
echo -e "${idsCL[White]}ServerRack Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${APCPDU_AMP}`'amps${idsCL[Default]}" echo -e "${idsCL[White]}ServerRack Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${APCPDU_AMP}`'amps${idsCL[Default]}"
MSG="${idsCL[White]}ServerRack Wattage ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${APCPDU_WATT}`'watts ${idsCL[Default]}~ estimate" MSG="${idsCL[White]}ServerRack Wattage ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${APCPDU_WATT}`'watts ${idsCL[Default]}~ estimate"
@@ -165,6 +169,7 @@ CHECKPOWER(){
# echo # echo
DIVIDER . lightCyan 75 DIVIDER . lightCyan 75
fi
echo -e "${idsCL[White]}Server Room Voltage IN ${idsCL[Default]}: ${idsCL[Green]}${SVRRM_VOLTIN}'volts${idsCL[Default]}" echo -e "${idsCL[White]}Server Room Voltage IN ${idsCL[Default]}: ${idsCL[Green]}${SVRRM_VOLTIN}'volts${idsCL[Default]}"
echo -e "${idsCL[White]}Server Room Voltage OUT ${idsCL[Default]}: ${idsCL[Green]}${SVRRM_VOLTOUT}'volts${idsCL[Default]}" echo -e "${idsCL[White]}Server Room Voltage OUT ${idsCL[Default]}: ${idsCL[Green]}${SVRRM_VOLTOUT}'volts${idsCL[Default]}"
@@ -328,10 +333,8 @@ CHECKPOWER(){
fi fi
done done
fi fi
[ ${REPORT} -eq 0 ] && end=`date +%s`; runtime=$((end-start)); echo -e "\nruntime: ${runtime}"
[ "${PW_ACTION}" != "" ] && [ ${REPORT} -eq 0 ] && echo
end=`date +%s`; runtime=$((end-start)); echo -e "\nruntime: ${runtime}"
[ "${PW_ACTION}" != "" ] && echo
} }
CHECKPOWER_SERVICE(){ CHECKPOWER_SERVICE(){