update
This commit is contained in:
@@ -1,6 +1,6 @@
|
|||||||
#!/usr/bin/env bash
|
#!/usr/bin/env bash
|
||||||
|
|
||||||
PW_VERS='2.10.1h-05312025'
|
PW_VERS='2.10.1m-05312025'
|
||||||
|
|
||||||
noheader=' update service dailytemp confsync -r -report test '
|
noheader=' update service dailytemp confsync -r -report test '
|
||||||
|
|
||||||
|
|||||||
@@ -838,7 +838,7 @@ BATT VOLTAGE: `IDS_NUMBER_FORMAT ${BATTVOLT}`'V ~ (`IDS_NUMBER_FORMAT ${BATTLIFE
|
|||||||
fi
|
fi
|
||||||
if [ ! -f ${PW_TMPFOLDER}/power.ac.good ]; then
|
if [ ! -f ${PW_TMPFOLDER}/power.ac.good ]; then
|
||||||
|
|
||||||
if [ -f ${PW_TMPFOLDER}/shutdown.SYS ] || [ -f ${PW_TMPFOLDER}/shutdown.MAIN ] || [ -f ${PW_TMPFOLDER}/power.ac.conserve ]; then
|
if [[ "${IP}" != "10.6.1"* ]] && ([ -f ${PW_TMPFOLDER}/shutdown.SYS ] || [ -f ${PW_TMPFOLDER}/shutdown.MAIN ] || [ -f ${PW_TMPFOLDER}/power.ac.conserve ]); then
|
||||||
SENDNOTICE "HOSTS POWER" "Power restored! Will wait ${PW_WAIT_TO_POWER_SERVERS}'mins before turning host(s) back on"
|
SENDNOTICE "HOSTS POWER" "Power restored! Will wait ${PW_WAIT_TO_POWER_SERVERS}'mins before turning host(s) back on"
|
||||||
touch ${PW_TMPFOLDER}/.power.restored
|
touch ${PW_TMPFOLDER}/.power.restored
|
||||||
fi
|
fi
|
||||||
|
|||||||
25
powerwall.sh
25
powerwall.sh
@@ -11,7 +11,7 @@ source /opt/idssys/powerwall/inc/power.inc.sh
|
|||||||
source /opt/idssys/powerwall/inc/temp.inc.sh
|
source /opt/idssys/powerwall/inc/temp.inc.sh
|
||||||
|
|
||||||
|
|
||||||
# TEST=true
|
[ "${TESTMODE_ENABLE}" == "true" ] && TEST=true
|
||||||
|
|
||||||
shopt -s lastpipe
|
shopt -s lastpipe
|
||||||
|
|
||||||
@@ -239,6 +239,28 @@ SHUTDOWN_SERVER(){
|
|||||||
hostname=${PW_ESXI_HOST_NAMES[${ESXI_HOST}]}
|
hostname=${PW_ESXI_HOST_NAMES[${ESXI_HOST}]}
|
||||||
fi
|
fi
|
||||||
|
|
||||||
|
if [[ "${IP}" == "10.6.1"* ]]; then
|
||||||
|
|
||||||
|
for ESXIHOST in "${ESXI_HOSTS[@]}"; do
|
||||||
|
MSG="Shutting down: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}"
|
||||||
|
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
|
||||||
|
echo -en "${idsCL[White]}${MSG//${PW_ESXI_HOST_NAMES[${ESXIHOST}]}/${idsCL[LightCyan]}${PW_ESXI_HOST_NAMES[${ESXIHOST}]}}${idsCL[White]}${MSG_SPC}: "
|
||||||
|
[[ "${PW_HOST_IDRACS[${PW_ESXI_HOST_NAMES[${ESXIHOST}]}]}" = "10.6."* ]] && ESXI_PASS=${PW_ESXI_PASS_KP} || ESXI_PASS=${PW_ESXI_PASS}
|
||||||
|
if [ "${TEST^^}" != "TRUE" ] && [ "${TEST_DONOT_SHUTDOWN^^}" != "TRUE" ]; then
|
||||||
|
if [ "$(ipmitool -I lanplus -H ${PW_HOST_IDRACS[${PW_ESXI_HOST_NAMES[${ESXIHOST}]}]} -U ${PW_ESXI_USER} -P "${ESXI_PASS}" chassis power status | grep 'Power is on')" != "" ]; then
|
||||||
|
ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${ESXIHOST} "/vmfs/volumes/ESXi-Vault (Fileserver)/!SCRIPTS/esxidown/async.sh"
|
||||||
|
echo -e "${idsCL[Green]}Command sent${idsCL[Default]}"
|
||||||
|
else
|
||||||
|
echo -e "${idsCL[Yellow]}Host Offline${idsCL[Default]}"
|
||||||
|
fi
|
||||||
|
else
|
||||||
|
echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}"
|
||||||
|
fi
|
||||||
|
done
|
||||||
|
|
||||||
|
|
||||||
|
else
|
||||||
|
|
||||||
echo
|
echo
|
||||||
DIVIDER . yellow ${PRI_WIDTH}
|
DIVIDER . yellow ${PRI_WIDTH}
|
||||||
[ ${MM} -eq 1 ] && smsg="Entering Maintenance Mode" || smsg="Shutting down"
|
[ ${MM} -eq 1 ] && smsg="Entering Maintenance Mode" || smsg="Shutting down"
|
||||||
@@ -504,6 +526,7 @@ SHUTDOWN_SERVER(){
|
|||||||
else
|
else
|
||||||
echo -e "${idsCL[LightRed]}Host cannot be found for '${1}'${idsCL[Default]}"
|
echo -e "${idsCL[LightRed]}Host cannot be found for '${1}'${idsCL[Default]}"
|
||||||
fi
|
fi
|
||||||
|
fi
|
||||||
echo
|
echo
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|||||||
Reference in New Issue
Block a user