update
This commit is contained in:
@@ -14,10 +14,17 @@ AVERAGEPOWER(){
|
||||
}
|
||||
|
||||
GET_OFFSITEHOST_FANSPEED(){
|
||||
vHOSTFAN=$(ssh root@${PW_RACADM_ACCESS} racadm -r 10.2.1.21 -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1)
|
||||
vHOSTFAN=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 root@${PW_RACADM_ACCESS} racadm -r 10.2.1.21 -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1)
|
||||
FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g')
|
||||
echo ${FanSpeed} > ${PW_TMPFOLDER}/.fanspeed
|
||||
}
|
||||
GET_HOST_FANSPEED(){
|
||||
for ESXIHOST in "${PW_ALLHOSTS[@]}"; do
|
||||
vHOSTFAN=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${PW_ESXI_HOST_NAMES[${ESXIHOST}]}]} -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1)
|
||||
FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g')
|
||||
echo ${FanSpeed} > ${PW_TMPFOLDER}/.fanspeed.${ESXIHOST}
|
||||
done
|
||||
}
|
||||
|
||||
CHECKPOWER(){
|
||||
start=`date +%s`
|
||||
@@ -42,7 +49,7 @@ CHECKPOWER(){
|
||||
done
|
||||
[ "${avgdays}" == "0" ] && unset avgdays
|
||||
[ "${avgdays}" != "" ] && avgdayshdr="${avgdays}-Day-Avg" || avgdayshdr=""
|
||||
[ "${PTYPE}" != "power" ] && GET_OFFSITEHOST_FANSPEED &
|
||||
[ "${PTYPE}" != "power" ] && GET_HOST_FANSPEED &
|
||||
|
||||
if ([ "${STYPE}" == "" ] || [ "${STYPE}" == "mainsite" ]) && [ "${PTYPE}" != "esxi" ]; then
|
||||
[ ${REPORT} -eq 0 ] && echo
|
||||
@@ -212,7 +219,7 @@ CHECKPOWER(){
|
||||
OFFSITE_BATT_RUNTIME=`echo "scale=2; ${OFFSITE_BATT_RUNTIME}/60" | bc`
|
||||
OFFSITE_BATT_CAP=$(echo "${upsinfo}" | grep 'battery.charge:' | sed 's/.*: //')
|
||||
|
||||
# vHOSTFAN=$(ssh root@${PW_RACADM_ACCESS} racadm -r 10.2.1.21 -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1)
|
||||
# vHOSTFAN=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 root@${PW_RACADM_ACCESS} racadm -r 10.2.1.21 -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1)
|
||||
# FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g')
|
||||
|
||||
# OFFSITE_VOLTIN=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.4.1.3808.1.1.1.3.2.1.0 | sed 's/.*: //')
|
||||
@@ -323,17 +330,17 @@ CHECKPOWER(){
|
||||
average=$(AVERAGEPOWER ${PW_POWERSENSOR_ID[${SENSOR}]} ${avgdays}); average_disp="${idsCL[LightYellow]} `IDS_NUMBER_FORMAT ${average}`'watts"
|
||||
echo -en "\r\033[K"; echo -en "${MSG}${idsCL[LightYellow]}${average_disp}"
|
||||
else
|
||||
if [ "${PW_HOST_IDRACS[${SENSOR}]}" == "10.2.1.21" ]; then
|
||||
# if [ "${PW_HOST_IDRACS[${SENSOR}]}" == "10.2.1.21" ]; then
|
||||
# vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSOR}]} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.3 -O vq)
|
||||
# FanSpeed=$(ROUND_NUMBER `echo "scale=0; $(ROUND_NUMBER `echo "scale=4; ${vHOSTFAN}/21200" | bc` 2)*100/1" | bc` 0)
|
||||
echo -en "${idsCL[LightCyan]} Getting FanSpeed..."
|
||||
until [ -f ${PW_TMPFOLDER}/.fanspeed ]; do tmp=tmp; done
|
||||
echo -en "\r\033[K${MSG}${idsCL[Cyan]} [PS1=${idsCL[LightCyan]}${PS1}'A${idsCL[Cyan]}, PS2=${idsCL[LightCyan]}${PS2}'A${idsCL[Cyan]}]${idsCL[LightCyan]} [FanSpeed=$(cat ${PW_TMPFOLDER}/.fanspeed)'%]"
|
||||
rm -f ${PW_TMPFOLDER}/.fanspeed
|
||||
until [ -f ${PW_TMPFOLDER}/.fanspeed.${PW_ESXI_HOST_NAMES[${SENSOR}]} ]; do tmp=tmp; done
|
||||
echo -en "\r\033[K${MSG}${idsCL[Cyan]} [PS1=${idsCL[LightCyan]}${PS1}'A${idsCL[Cyan]}, PS2=${idsCL[LightCyan]}${PS2}'A${idsCL[Cyan]}]${idsCL[LightCyan]} [FanSpeed=$(cat ${PW_TMPFOLDER}/.fanspeed.${PW_ESXI_HOST_NAMES[${SENSOR}]})'%]"
|
||||
rm -f ${PW_TMPFOLDER}/.fanspeed.${PW_ESXI_HOST_NAMES[${SENSOR}]}
|
||||
|
||||
else
|
||||
echo -en "${idsCL[Cyan]} [PS1=${idsCL[LightCyan]}${PS1}'A${idsCL[Cyan]}, PS2=${idsCL[LightCyan]}${PS2}'A${idsCL[Cyan]}]"
|
||||
fi
|
||||
# else
|
||||
# echo -en "${idsCL[Cyan]} [PS1=${idsCL[LightCyan]}${PS1}'A${idsCL[Cyan]}, PS2=${idsCL[LightCyan]}${PS2}'A${idsCL[Cyan]}]"
|
||||
# fi
|
||||
fi
|
||||
fi
|
||||
echo -e "${idsCL[Default]}"
|
||||
@@ -534,7 +541,7 @@ Shutting down main servers" 1
|
||||
######offsite check
|
||||
|
||||
# if [ "$(CHECK_HOST 10.2.1.1)" != "false" ]; then
|
||||
# upsinfo=$(ssh admin@10.2.1.1 'upsc CP1500PFCLCD')
|
||||
# upsinfo=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 admin@10.2.1.1 'upsc CP1500PFCLCD')
|
||||
# OFFSITE_VOLTIN=$(echo "${upsinfo}" | grep 'input.voltage:' | sed 's/.*: //')
|
||||
# OFFSITE_BATT_RUNTIME=$(echo "${upsinfo}" | grep 'battery.runtime:' | sed 's/.*: //')
|
||||
# OFFSITE_BATT_RUNTIME=`echo "scale=2; ${OFFSITE_BATT_RUNTIME}/60" | bc`
|
||||
|
||||
Reference in New Issue