update
This commit is contained in:
@@ -1,6 +1,6 @@
|
|||||||
#!/usr/bin/env bash
|
#!/usr/bin/env bash
|
||||||
|
|
||||||
VERS='2.5.231-02012024'
|
VERS='2.5.232-02012024'
|
||||||
|
|
||||||
noheader=' update service dailytemp confsync -r -report '
|
noheader=' update service dailytemp confsync -r -report '
|
||||||
|
|
||||||
|
|||||||
100
powerwall.sh
100
powerwall.sh
@@ -248,42 +248,36 @@ SHUTDOWN_SERVER(){
|
|||||||
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
|
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
|
||||||
echo -en "${idsCL[White]}${MSG}${MSG_SPC}: "
|
echo -en "${idsCL[White]}${MSG}${MSG_SPC}: "
|
||||||
if [ "${TEST}" != "true" ]; then
|
if [ "${TEST}" != "true" ]; then
|
||||||
${PW_FOLDER}/esxi-scripts/set-drs.ps1 3 >/dev/null 2>&1
|
${PW_FOLDER}/esxi-scripts/set-drs.ps1 3 >/dev/null 2>&1 &
|
||||||
echo -e "${idsCL[Green]}Done${idsCL[Default]}\n"
|
echo -e "${idsCL[Green]}Command Sent${idsCL[Default]}\n"
|
||||||
else
|
else
|
||||||
echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}\n"
|
echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}\n"
|
||||||
fi
|
fi
|
||||||
fi
|
fi
|
||||||
|
|
||||||
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ] || [ "${ESXI_HOST}" == "SYS" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ] || [ "${ESXI_HOST}" == "SYS" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
||||||
# for ESXIHOST in "${PW_MAINSITEHOSTS[@]}"; do
|
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
||||||
|
MSG="Stopping all iSCSI-PRI VM's"
|
||||||
|
elif [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "SYS" ]; then
|
||||||
|
MSG="Stopping all iSCSI-SYS VM's"
|
||||||
|
elif [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ]; then
|
||||||
|
MSG="Stopping all iSCSI VM's"
|
||||||
|
fi
|
||||||
|
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
|
||||||
|
echo -en "${idsCL[White]}${MSG}${idsCL[White]}${MSG_SPC}: "
|
||||||
|
if [ "${TEST}" != "true" ]; then
|
||||||
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
||||||
MSG="Stopping all iSCSI-PRI VM's"
|
${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown.ps1 >/dev/null 2>&1 &
|
||||||
elif [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "SYS" ]; then
|
elif [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "SYS" ]; then
|
||||||
MSG="Stopping all iSCSI-SYS VM's"
|
${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown.ps1 >/dev/null 2>&1 &
|
||||||
elif [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ]; then
|
elif [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ]; then
|
||||||
MSG="Stopping all iSCSI VM's"
|
${PW_FOLDER}/esxi-scripts/iscsi-all-vm-shutdown.ps1 >/dev/null 2>&1 &
|
||||||
fi
|
fi
|
||||||
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
|
sleep 5s
|
||||||
echo -en "${idsCL[White]}${MSG}${idsCL[White]}${MSG_SPC}: "
|
echo -e "${idsCL[Green]}Command sent${idsCL[Default]}"
|
||||||
if [ "${TEST}" != "true" ]; then
|
else
|
||||||
# if [ "$(ipmitool -I lanplus -H ${PW_HOST_IDRACS[${PW_ESXI_HOST_NAMES[${ESXIHOST}]}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" chassis power status | grep 'Power is on')" != "" ]; then
|
echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}"
|
||||||
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
fi
|
||||||
${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown.ps1 >/dev/null 2>&1 &
|
|
||||||
elif [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "SYS" ]; then
|
|
||||||
${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown.ps1 >/dev/null 2>&1 &
|
|
||||||
elif [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ]; then
|
|
||||||
${PW_FOLDER}/esxi-scripts/iscsi-all-vm-shutdown.ps1 >/dev/null 2>&1 &
|
|
||||||
fi
|
|
||||||
sleep 5s
|
|
||||||
echo -e "${idsCL[Green]}Commands sent${idsCL[Default]}"
|
|
||||||
# else
|
|
||||||
# echo -e "${idsCL[Yellow]}Host Offline${idsCL[Default]}"
|
|
||||||
# fi
|
|
||||||
else
|
|
||||||
echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}"
|
|
||||||
fi
|
|
||||||
# done
|
|
||||||
echo
|
echo
|
||||||
fi
|
fi
|
||||||
|
|
||||||
@@ -409,7 +403,7 @@ SHUTDOWN_SERVER(){
|
|||||||
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 10.10.2.10 >/dev/null 2>&1 &
|
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 10.10.2.10 >/dev/null 2>&1 &
|
||||||
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 10.10.2.17 >/dev/null 2>&1 &
|
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 10.10.2.17 >/dev/null 2>&1 &
|
||||||
fi
|
fi
|
||||||
echo -e "${idsCL[Green]}Commands sent${idsCL[Default]}"
|
echo -e "${idsCL[Green]}Command sent${idsCL[Default]}"
|
||||||
else
|
else
|
||||||
echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}"
|
echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}"
|
||||||
fi
|
fi
|
||||||
@@ -424,7 +418,7 @@ SHUTDOWN_SERVER(){
|
|||||||
varvms="${PW_VCENTER_HOST_NAMES[${ESXIHOST}]},${varvms}"
|
varvms="${PW_VCENTER_HOST_NAMES[${ESXIHOST}]},${varvms}"
|
||||||
done
|
done
|
||||||
${PW_FOLDER}/esxi-scripts/vm-shutdown.ps1 "${varvms::-1}" >/dev/null 2>&1 &
|
${PW_FOLDER}/esxi-scripts/vm-shutdown.ps1 "${varvms::-1}" >/dev/null 2>&1 &
|
||||||
echo -e "${idsCL[Green]}Commands sent${idsCL[Default]}"
|
echo -e "${idsCL[Green]}Command sent${idsCL[Default]}"
|
||||||
|
|
||||||
else
|
else
|
||||||
echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}"
|
echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}"
|
||||||
@@ -638,17 +632,15 @@ HOSTMGMT(){
|
|||||||
|
|
||||||
if [ "${POWER^^}" == "ON" ] && ([ "${ESXI_HOST}" == "ALL" ] || [ "${ESXI_HOST}" == "MAINSITE" ]); then
|
if [ "${POWER^^}" == "ON" ] && ([ "${ESXI_HOST}" == "ALL" ] || [ "${ESXI_HOST}" == "MAINSITE" ]); then
|
||||||
##DECREASE CPU OVERCOMMIT
|
##DECREASE CPU OVERCOMMIT
|
||||||
if [[ "${PW_OFFSITE_HOSTS}" != *"${ESXI_HOST}"* ]] && [ "${ESXI_HOST}" != "OFFSITE" ]; then
|
MSG="Decreasing DRS CPU-Overcommit back down to 2"
|
||||||
MSG="Decreasing DRS CPU-Overcommit back down to 2"
|
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
|
||||||
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
|
echo -en "${idsCL[White]}${MSG}${MSG_SPC}: "
|
||||||
echo -en "${idsCL[White]}${MSG}${MSG_SPC}: "
|
if [ "${TEST}" != "true" ]; then
|
||||||
if [ "${TEST}" != "true" ]; then
|
${PW_FOLDER}/esxi-scripts/set-drs.ps1 2 >/dev/null 2>&1 &
|
||||||
${PW_FOLDER}/esxi-scripts/set-drs.ps1 2 >/dev/null 2>&1
|
echo -e "${idsCL[Green]}Command Sent${idsCL[Default]}\n"
|
||||||
echo -e "${idsCL[Green]}Done${idsCL[Default]}\n"
|
else
|
||||||
else
|
echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}\n"
|
||||||
echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}\n"
|
fi
|
||||||
fi
|
|
||||||
fi
|
|
||||||
fi
|
fi
|
||||||
else
|
else
|
||||||
HOSTPOWER ${ESXI_HOST} ${POWER}
|
HOSTPOWER ${ESXI_HOST} ${POWER}
|
||||||
@@ -659,34 +651,28 @@ HOSTMGMT(){
|
|||||||
}
|
}
|
||||||
|
|
||||||
ISCSIVMSHUTDOWN(){
|
ISCSIVMSHUTDOWN(){
|
||||||
for ESXIHOST in "${PW_MAINSITEHOSTS[@]}"; do
|
echo -en "${idsCL[LightCyan]}Shutting down any VM's that are running on an iSCSI-PRI drive ... "
|
||||||
echo -en "${idsCL[LightCyan]}Shutting down any VM's on '${ESXIHOST}' that are running on an iSCSI-PRI drive ... "
|
${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown.ps1 >/dev/null 2>&1 &
|
||||||
${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1 &
|
echo -e "${idsCL[Green]}Command sent${idsCL[Default]}"
|
||||||
echo -e "${idsCL[Green]}Commands sent${idsCL[Default]}"
|
echo
|
||||||
echo
|
|
||||||
done
|
|
||||||
|
|
||||||
echo -e "${idsCL[LightCyan]}Please wait a few minutes while all iSCSI guests are shutdown ..."
|
echo -e "${idsCL[LightCyan]}Please wait a few minutes while all iSCSI guests are shutdown ..."
|
||||||
echo
|
echo
|
||||||
}
|
}
|
||||||
ISCSISYSSHUTDOWN(){
|
ISCSISYSSHUTDOWN(){
|
||||||
for ESXIHOST in "${PW_MAINSITEHOSTS[@]}"; do
|
echo -en "${idsCL[LightCyan]}Shutting down any VM's that are running on an iSCSI-SYS drive ... "
|
||||||
echo -en "${idsCL[LightCyan]}Shutting down any VM's on '${ESXIHOST}' that are running on an iSCSI-SYS drive ... "
|
${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown.ps1 >/dev/null 2>&1 &
|
||||||
${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1 &
|
echo -e "${idsCL[Green]}Command sent${idsCL[Default]}"
|
||||||
echo -e "${idsCL[Green]}Commands sent${idsCL[Default]}"
|
echo
|
||||||
echo
|
|
||||||
done
|
|
||||||
|
|
||||||
echo -e "${idsCL[LightCyan]}Please wait a few minutes while all iSCSI guests are shutdown ..."
|
echo -e "${idsCL[LightCyan]}Please wait a few minutes while all iSCSI guests are shutdown ..."
|
||||||
echo
|
echo
|
||||||
}
|
}
|
||||||
ISCSIALLSHUTDOWN(){
|
ISCSIALLSHUTDOWN(){
|
||||||
for ESXIHOST in "${PW_MAINSITEHOSTS[@]}"; do
|
echo -en "${idsCL[LightCyan]}Shutting down any VM's that are running on any iSCSI drive ... "
|
||||||
echo -en "${idsCL[LightCyan]}Shutting down any VM's on '${ESXIHOST}' that are running on any iSCSI drive ... "
|
${PW_FOLDER}/esxi-scripts/iscsi-all-vm-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1 &
|
||||||
${PW_FOLDER}/esxi-scripts/iscsi-all-vm-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1 &
|
echo -e "${idsCL[Green]}Command sent${idsCL[Default]}"
|
||||||
echo -e "${idsCL[Green]}Commands sent${idsCL[Default]}"
|
echo
|
||||||
echo
|
|
||||||
done
|
|
||||||
|
|
||||||
echo -e "${idsCL[LightCyan]}Please wait a few minutes while all iSCSI guests are shutdown ..."
|
echo -e "${idsCL[LightCyan]}Please wait a few minutes while all iSCSI guests are shutdown ..."
|
||||||
echo
|
echo
|
||||||
|
|||||||
Reference in New Issue
Block a user