This commit is contained in:
2024-11-20 22:26:36 -06:00
parent 7f0d1b7b81
commit 95ba0e175d
3 changed files with 22 additions and 22 deletions

View File

@@ -260,10 +260,10 @@ SHUTDOWN_SERVER(){
fi
fi
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ] || [ "${ESXI_HOST}" == "SYS" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
if [ "${ESXI_HOST}" == "${PW_ISCSI_PRI_HOST}" ] || [ "${ESXI_HOST}" == "${PW_ISCSI_SYS_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ] || [ "${ESXI_HOST}" == "SYS" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
if [ "${ESXI_HOST}" == "${PW_ISCSI_PRI_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
MSG="Stopping all iSCSI-PRI VM's"
elif [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "SYS" ]; then
elif [ "${ESXI_HOST}" == "${PW_ISCSI_SYS_HOST}" ] || [ "${ESXI_HOST}" == "SYS" ]; then
MSG="Stopping all iSCSI-SYS VM's"
elif [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ]; then
MSG="Stopping all iSCSI VM's"
@@ -271,9 +271,9 @@ SHUTDOWN_SERVER(){
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
echo -en "${idsCL[White]}${MSG}${idsCL[White]}${MSG_SPC}: "
if [ "${TEST}" != "true" ]; then
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
if [ "${ESXI_HOST}" == "${PW_ISCSI_PRI_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown.ps1 >/dev/null 2>&1 &
elif [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "SYS" ]; then
elif [ "${ESXI_HOST}" == "${PW_ISCSI_SYS_HOST}" ] || [ "${ESXI_HOST}" == "SYS" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown.ps1 >/dev/null 2>&1 &
elif [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-all-vm-shutdown.ps1 >/dev/null 2>&1 &
@@ -356,15 +356,15 @@ SHUTDOWN_SERVER(){
echo
fi
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ] || [ "${ESXI_HOST}" == "SYS" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
if [ "${ESXI_HOST}" == "${PW_ISCSI_PRI_HOST}" ] || [ "${ESXI_HOST}" == "${PW_ISCSI_SYS_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ] || [ "${ESXI_HOST}" == "SYS" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
MSG="Waiting for iSCSI VM's to power down"
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
echo -en "${idsCL[White]}${MSG}${idsCL[White]}${MSG_SPC}: "
# for ESXIHOST in "${PW_MAINSITEHOSTS[@]}"; do
if [ "${TEST}" != "true" ]; then
if [ "${1}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${1}" == "MAIN" ]; then
if [ "${1}" == "${PW_ISCSI_PRI_HOST}" ] || [ "${1}" == "MAIN" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown-verify.ps1 >/dev/null 2>&1
elif [ "${1}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${1}" == "SYS" ]; then
elif [ "${1}" == "${PW_ISCSI_SYS_HOST}" ] || [ "${1}" == "SYS" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown-verify.ps1 >/dev/null 2>&1
elif [ "${1}" == "MAINSITE" ] || [ "${1}" == "ALL" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-all-shutdown-verify.ps1 >/dev/null 2>&1
@@ -390,9 +390,9 @@ SHUTDOWN_SERVER(){
# echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}"
# fi
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
if [ "${ESXI_HOST}" == "${PW_ISCSI_PRI_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
MSG="Shutting down iSCSI-PRI Server"
elif [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "SYS" ]; then
elif [ "${ESXI_HOST}" == "${PW_ISCSI_SYS_HOST}" ] || [ "${ESXI_HOST}" == "SYS" ]; then
MSG="Shutting down iSCSI-SYS Server"
elif [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ]; then
MSG="Shutting down both iSCSI-PRI & iSCSI-SYS Servers"
@@ -400,13 +400,13 @@ SHUTDOWN_SERVER(){
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
echo -en "${idsCL[White]}${MSG}${MSG_SPC}: "
if [ "${TEST}" != "true" ]; then
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${PW_ISCSI-PRI_HOST} >/dev/null 2>&1 &
elif [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "SYS" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${PW_ISCSI-SYS_HOST} >/dev/null 2>&1 &
if [ "${ESXI_HOST}" == "${PW_ISCSI_PRI_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${PW_ISCSI_PRI_HOST} >/dev/null 2>&1 &
elif [ "${ESXI_HOST}" == "${PW_ISCSI_SYS_HOST}" ] || [ "${ESXI_HOST}" == "SYS" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${PW_ISCSI_SYS_HOST} >/dev/null 2>&1 &
elif [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${PW_ISCSI-PRI_HOST} >/dev/null 2>&1 &
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${PW_ISCSI-SYS_HOST} >/dev/null 2>&1 &
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${PW_ISCSI_PRI_HOST} >/dev/null 2>&1 &
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${PW_ISCSI_SYS_HOST} >/dev/null 2>&1 &
fi
echo -e "${idsCL[Green]}Command sent${idsCL[Default]}"
else
@@ -499,9 +499,9 @@ SHUTDOWN_SERVER(){
}
VERIFY_ISCSI_VM_DOWN(){
if [ "${1}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${1}" == "MAIN" ]; then
if [ "${1}" == "${PW_ISCSI_PRI_HOST}" ] || [ "${1}" == "MAIN" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown-verify.ps1 >/dev/null 2>&1
elif [ "${1}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${1}" == "SYS" ]; then
elif [ "${1}" == "${PW_ISCSI_SYS_HOST}" ] || [ "${1}" == "SYS" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown-verify.ps1 >/dev/null 2>&1
elif [ "${1}" == "MAINSITE" ] || [ "${1}" == "ALL" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-all-shutdown-verify.ps1 >/dev/null 2>&1