diff --git a/defaults.inc b/defaults.inc index 77cda653..4068fde0 100755 --- a/defaults.inc +++ b/defaults.inc @@ -1,6 +1,6 @@ #!/usr/bin/env bash -PW_VERS='2.10.11-06032025' +PW_VERS='2.10.12-06032025' noheader=' update service dailytemp confsync -r -report test ' @@ -13,6 +13,8 @@ NM_FOLDER='/opt/idssys/nodemgmt' NM_TMPFOLDER=${NM_FOLDER}/.tmp [ -f ${NM_FOLDER}/conf/defaults.local.inc ] && source ${NM_FOLDER}/defaults.inc +SSHCMD='ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1' + [ "${TESTMODE_ENABLE^^}" == "TRUE" ] && TESTMODE=1 || TESTMODE=0 PW_FOLDER='/opt/idssys/powerwall' diff --git a/inc/power.inc.sh b/inc/power.inc.sh index facac202..08766edb 100644 --- a/inc/power.inc.sh +++ b/inc/power.inc.sh @@ -447,11 +447,7 @@ CHECKPOWER(){ [ ${REPORT} -eq 0 ] && echo -en "${idsCL[Yellow]}Pulling data from 'Offsite' ... " - if [ "${PW_OFFSITE_MONITOR}" = "$(ip addr show $(ip route | awk '/default/ { print $5 }') | grep "inet" | head -n 1 | awk '/inet/ {print $2}' | cut -d'/' -f1)" ]; then - upsinfo=$(upsc offsite-ups 2>&1) - else - upsinfo=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_OFFSITE_MONITOR} 'upsc offsite-ups' 2>&1) - fi + [ "${PW_OFFSITE_MONITOR}" == "${IP}" ] && upsinfo=$(upsc offsite-ups 2>&1) || upsinfo=$(${SSHCMD} root@${PW_OFFSITE_MONITOR} 'upsc offsite-ups' 2>&1) if [ "$(echo "${upsinfo}" | grep 'input.voltage:')" != "" ]; then OFFSITE_STATUS=$(echo "${upsinfo}" | grep 'ups.status:' | sed 's/.*: //') [ "${PW_OFFSITE_UPS_CODES[${OFFSITE_STATUS}]}" != "" ] && OFFSITE_STATUS=${PW_OFFSITE_UPS_CODES[${OFFSITE_STATUS}]} || OFFSITE_STATUS=${OFFSITE_STATUS} @@ -1008,8 +1004,7 @@ OFFSITE_CHECKPOWER_SERVICE(){ TESTMSG="" fi - # upsinfo=$(upsc offsite-ups) - upsinfo=$(upsc offsite-ups 2>&1) + [ "${PW_OFFSITE_MONITOR}" == "${IP}" ] && upsinfo=$(upsc offsite-ups 2>&1) || upsinfo=$(${SSHCMD} root@${PW_OFFSITE_MONITOR} 'upsc offsite-ups' 2>&1) echo "HERE1: $upsinfo" if [ "$(echo "${upsinfo}" | grep 'input.voltage:' | sed 's/.*: //')" != "" ]; then rm -f ${PW_TMPFOLDER}/power.offsite.ups.losscomm @@ -1288,11 +1283,7 @@ POWERLOGGER_SERVICE(){ fi - if [ "${PW_OFFSITE_MONITOR}" = "$(ip addr show $(ip route | awk '/default/ { print $5 }') | grep "inet" | head -n 1 | awk '/inet/ {print $2}' | cut -d'/' -f1)" ]; then - upsinfo=$(upsc offsite-ups 2>&1) - else - upsinfo=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_OFFSITE_MONITOR} 'upsc offsite-ups' 2>&1) - fi + [ "${PW_OFFSITE_MONITOR}" == "${IP}" ] && upsinfo=$(upsc offsite-ups 2>&1) || upsinfo=$(${SSHCMD} root@${PW_OFFSITE_MONITOR} 'upsc offsite-ups' 2>&1) if [ "$(echo "${upsinfo}" | grep 'input.voltage:')" != "" ]; then OFFSITE_VOLTOUT=$(echo "${upsinfo}" | grep 'output.voltage:' | sed 's/.*: //') OFFSITE_LOAD=$(echo "${upsinfo}" | grep 'ups.load:' | sed 's/.*: //') diff --git a/inc/temp.inc.sh b/inc/temp.inc.sh index 47973559..e2dfbcbe 100644 --- a/inc/temp.inc.sh +++ b/inc/temp.inc.sh @@ -3,7 +3,7 @@ GET_HOST_FANSPEED(){ FanSpeed=$(cat ${PW_TMPFOLDER}/.lastfancheck/${PW_ESXI_HOST_NAMES[${1}]}) else [[ "${PW_HOST_IDRACS[${PW_ESXI_HOST_NAMES[${1}]}]}" = "10.6."* ]] && ESXI_PASS=${PW_ESXI_PASS_KP} || ESXI_PASS=${PW_ESXI_PASS} - vHOSTFAN=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${PW_ESXI_HOST_NAMES[${1}]}]} -u ${PW_ESXI_USER} -p "'${ESXI_PASS}'" getsensorinfo | grep "System Board Fan3" 2>&1) + vHOSTFAN=$(${SSHCMD} root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${PW_ESXI_HOST_NAMES[${1}]}]} -u ${PW_ESXI_USER} -p "'${ESXI_PASS}'" getsensorinfo | grep "System Board Fan3" 2>&1) if [ "$(echo ${vHOSTFAN} | awk '/ / {print $4}' | sed -e 's/%//g')" == "RPM" ]; then FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $9}' | sed -e 's/%//g') else @@ -13,7 +13,7 @@ GET_HOST_FANSPEED(){ echo ${FanSpeed} > ${PW_TMPFOLDER}/.local.fanspeed.${PW_ESXI_HOST_NAMES[${1}]}.${2} } START_POWERWALL_FAN(){ - PWCMD="ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_REMOTE_SENSORS['Powerwall-FAN']}" + PWCMD="${SSHCMD} root@${PW_REMOTE_SENSORS['Powerwall-FAN']}" ${PWCMD} pwmconfig & sleep 4s ${PWCMD} killall pwmconfig >/dev/null 2>&1 @@ -670,7 +670,7 @@ CHECKTEMP(){ if [ ${drives} -eq 1 ]; then - ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${vHOSTIP} 'wget -qO- https://git.schroedercity.com/voltron/Misc-Scripts/raw/branch/master/ESXi-GetPercDriveTemps.sh | sh' + ${SSHCMD} root@${vHOSTIP} 'wget -qO- https://git.schroedercity.com/voltron/Misc-Scripts/raw/branch/master/ESXi-GetPercDriveTemps.sh | sh' fi @@ -732,12 +732,12 @@ CHECKTEMPSENSOR(){ elif [ "${PW_SENSOR_TYPE[${1}]}" == "system" ]; then if [[ "${1}" = *"CPU"* ]]; then - if ! temp_c=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_REMOTE_SENSORS[${1}]} vcgencmd measure_temp) ; then TIMEOUT=1; fi + if ! temp_c=$(${SSHCMD} root@${PW_REMOTE_SENSORS[${1}]} vcgencmd measure_temp) ; then TIMEOUT=1; fi if [ "${temp_c}" != "" ]; then temp_c=${temp_c%\'*}; temp_c=${temp_c#*=} fi elif [[ "${1}" = *"FAN"* ]]; then - if ! temp_c=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_REMOTE_SENSORS[${1}]} cat ${PW_FANINPUT}) ; then TIMEOUT=1; fi + if ! temp_c=$(${SSHCMD} root@${PW_REMOTE_SENSORS[${1}]} cat ${PW_FANINPUT}) ; then TIMEOUT=1; fi fi elif [ "${PW_SENSOR_TYPE[${1}]}" == "esxi" ]; then @@ -750,13 +750,13 @@ CHECKTEMPSENSOR(){ TIMEOUT=1 fi else - if ! temp_c=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_REMOTE_SENSORS[${1}]} "/opt/idssys/defaults/get-data.sh cpu-usage") ; then + if ! temp_c=$(${SSHCMD} root@${PW_REMOTE_SENSORS[${1}]} "/opt/idssys/defaults/get-data.sh cpu-usage") ; then TIMEOUT=1 fi fi elif [ "${PW_SENSOR_TYPE[${1}]}" == "ds18b20" ]; then - if ! temp_c=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_REMOTE_SENSORS[${1}]} cat /sys/bus/w1/devices/${PW_SENSOR_DEVICEID[${1}]}/w1_slave | tail -n1 | cut -d "=" -f2) ; then TIMEOUT=1; fi + if ! temp_c=$(${SSHCMD} root@${PW_REMOTE_SENSORS[${1}]} cat /sys/bus/w1/devices/${PW_SENSOR_DEVICEID[${1}]}/w1_slave | tail -n1 | cut -d "=" -f2) ; then TIMEOUT=1; fi [ "${temp_c}" != "" ] && temp_c=$(echo "scale=2; ${temp_c}/1000" | bc) fi @@ -936,8 +936,8 @@ CHECKTEMP_SERVICE_RUNSENSOR(){ # if [ ! -f ${PW_TMPFOLDER}/${SENSORa}.down ] && ([ ! -f ${PW_TMPFOLDER}/.lastfancheck/${SENSORa} ] || [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/.lastfancheck/${SENSORa})) -ge 60 ]); then if [ ! -f ${PW_TMPFOLDER}/${SENSORa}.down ]; then # vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSORa}]} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.3 -O vq) - vHOSTFAN=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${SENSORa}]} -u ${PW_ESXI_USER} -p "'${ESXI_PASS}'" getsensorinfo | grep "System Board Fan3" 2>&1) - [ "${vHOSTFAN}" = "" ] && vHOSTFAN=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${SENSORa}]} -u ${PW_ESXI_USER} -p "'${ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1) + vHOSTFAN=$(${SSHCMD} root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${SENSORa}]} -u ${PW_ESXI_USER} -p "'${ESXI_PASS}'" getsensorinfo | grep "System Board Fan3" 2>&1) + [ "${vHOSTFAN}" = "" ] && vHOSTFAN=$(${SSHCMD} root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${SENSORa}]} -u ${PW_ESXI_USER} -p "'${ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1) if [ "${vHOSTFAN}" != "" ]; then # FanSpeed=`echo "scale=2; ${vHOSTFAN}/21200" | bc`; FanSpeed=$(ROUND_NUMBER `echo "scale=0; ${FanSpeed}*100" | bc | sed -e 's/.00//g'` 0) if [ "$(echo ${vHOSTFAN} | awk '/ / {print $4}' | sed -e 's/%//g')" == "RPM" ]; then @@ -1004,12 +1004,12 @@ CHECKTEMP_SERVICE_RUNSENSOR(){ elif [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "system" ]; then if [[ "${SENSOR}" = *"CPU"* ]]; then - if ! temp_c=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_REMOTE_SENSORS[${SENSOR}]} vcgencmd measure_temp) ; then TIMEOUT=1; fi + if ! temp_c=$(${SSHCMD} root@${PW_REMOTE_SENSORS[${SENSOR}]} vcgencmd measure_temp) ; then TIMEOUT=1; fi if [ "${temp_c}" != "" ]; then temp_c=${temp_c%\'*}; temp_c=${temp_c#*=} fi elif [[ "${SENSOR}" = *"FAN"* ]]; then - if ! temp_c=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_REMOTE_SENSORS[${SENSOR}]} cat ${PW_FANINPUT}) ; then TIMEOUT=1; fi + if ! temp_c=$(${SSHCMD} root@${PW_REMOTE_SENSORS[${SENSOR}]} cat ${PW_FANINPUT}) ; then TIMEOUT=1; fi if [ "${SENSOR}" == "Powerwall-FAN" ] && [ ${temp_c} -lt 1500 ]; then START_POWERWALL_FAN >/dev/null 2>&1 & fi @@ -1034,12 +1034,12 @@ CHECKTEMP_SERVICE_RUNSENSOR(){ if [ "${SENSORa}" == "Powerwall-CPU-Usage" ]; then temp_c=$(awk '{u=$2+$4; t=$2+$4+$5; if (NR==1){u1=u; t1=t;} else print ($2+$4-u1) * 100 / (t-t1) "%"; }' <(grep 'cpu ' /proc/stat) <(sleep 1;grep 'cpu ' /proc/stat) | sed -e 's/%//g') else - temp_c=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_REMOTE_SENSORS[${SENSORa}]} "/opt/idssys/defaults/get-data.sh cpu-usage") + temp_c=$(${SSHCMD} root@${PW_REMOTE_SENSORS[${SENSORa}]} "/opt/idssys/defaults/get-data.sh cpu-usage") fi temp_h='' elif [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "ds18b20" ]; then - if ! temp_c=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_REMOTE_SENSORS[${SENSORa}]} cat /sys/bus/w1/devices/${PW_SENSOR_DEVICEID[${SENSORa}]}/w1_slave | tail -n1 | cut -d "=" -f2) ; then TIMEOUT=1; fi + if ! temp_c=$(${SSHCMD} root@${PW_REMOTE_SENSORS[${SENSORa}]} cat /sys/bus/w1/devices/${PW_SENSOR_DEVICEID[${SENSORa}]}/w1_slave | tail -n1 | cut -d "=" -f2) ; then TIMEOUT=1; fi [ "${temp_c}" != "" ] && temp_c=$(echo "scale=2; ${temp_c}/1000" | bc) temp_h='' @@ -1656,7 +1656,7 @@ SENDTEMP(){ fi elif [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "remotesystem" ]; then - temp_c=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_REMOTE_SENSORS[${SENSORa}]} vcgencmd measure_temp) + temp_c=$(${SSHCMD} root@${PW_REMOTE_SENSORS[${SENSORa}]} vcgencmd measure_temp) if [ "${temp_c}" != "" ]; then temp_c=${temp_c%\'*} temp_c=${temp_c#*=} @@ -1670,11 +1670,11 @@ SENDTEMP(){ if [ "${SENSORa}" == "Powerwall-CPU-Usage" ]; then temp_c=$(awk '{u=$2+$4; t=$2+$4+$5; if (NR==1){u1=u; t1=t;} else print ($2+$4-u1) * 100 / (t-t1) "%"; }' <(grep 'cpu ' /proc/stat) <(sleep 1;grep 'cpu ' /proc/stat) | sed -e 's/%//g') else - temp_c=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_REMOTE_SENSORS[${SENSORa}]} "/opt/idssys/defaults/get-data.sh cpu-usage") + temp_c=$(${SSHCMD} root@${PW_REMOTE_SENSORS[${SENSORa}]} "/opt/idssys/defaults/get-data.sh cpu-usage") fi elif [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "ds18b20" ]; then - if ! temp_c=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_REMOTE_SENSORS[${SENSORa}]} cat /sys/bus/w1/devices/${PW_SENSOR_DEVICEID[${SENSORa}]}/w1_slave | tail -n1 | cut -d "=" -f2) ; then TIMEOUT=1; fi + if ! temp_c=$(${SSHCMD} root@${PW_REMOTE_SENSORS[${SENSORa}]} cat /sys/bus/w1/devices/${PW_SENSOR_DEVICEID[${SENSORa}]}/w1_slave | tail -n1 | cut -d "=" -f2) ; then TIMEOUT=1; fi [ "${temp_c}" != "" ] && temp_c=$(echo "scale=2; ${temp_c}/1000" | bc) else diff --git a/powerwall.sh b/powerwall.sh index 41de2256..c001eb5d 100755 --- a/powerwall.sh +++ b/powerwall.sh @@ -134,13 +134,13 @@ SHUTDOWN_CRIT(){ echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - CRITICAL TEMP - OctoPi System shutting down" >> ${PW_LOGFOLDER}/log-temp-${1} echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${1} TEMP CRITICAL - OctoPi System shutting down" >> ${PW_LOGFILE} sleep 1s - ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_REMOTE_SENSORS[${1}]} /sbin/poweroff + ${SSHCMD} root@${PW_REMOTE_SENSORS[${1}]} /sbin/poweroff elif [ "${1}" == "OctoPi-CPU-Usage" ]; then SENDNOTICE "${1} USAGE CRITICAL" "OctoPi System rebooting" 1 echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - CRITICAL USAGE - OctoPi System rebooting" >> ${PW_LOGFOLDER}/log-temp-${1} echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${1} USAGE CRITICAL - OctoPi System rebooting" >> ${PW_LOGFILE} - ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_REMOTE_SENSORS[${1}]} /sbin/reboot + ${SSHCMD} root@${PW_REMOTE_SENSORS[${1}]} /sbin/reboot fi } @@ -170,16 +170,16 @@ MAINT_MODE_VERIFY_SHUTDOWN(){ MaintMode="" until [ "${MaintMode}" == "Enabled" ]; do sleep 3s - MaintMode=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${ESXIHOST} 'esxcli system maintenanceMode get') + MaintMode=$(${SSHCMD} root@${ESXIHOST} 'esxcli system maintenanceMode get') done rm -f ${PW_TMPFOLDER}/${PW_ESXI_HOST_NAMES[${ESXIHOST}]}.* touch ${PW_TMPFOLDER}/${PW_ESXI_HOST_NAMES[${ESXIHOST}]}.disable # touch ${PW_TMPFOLDER}/${PW_ESXI_HOST_NAMES[${ESXIHOST}]}.down - ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${ESXIHOST} 'esxcli system shutdown poweroff -d 10 -r "Power-Monitor script initiated system shutdown"' + ${SSHCMD} root@${ESXIHOST} 'esxcli system shutdown poweroff -d 10 -r "Power-Monitor script initiated system shutdown"' sleep 8.75s - ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${ESXIHOST} 'esxcli system maintenanceMode set -e false -t 0' + ${SSHCMD} root@${ESXIHOST} 'esxcli system maintenanceMode set -e false -t 0' } SHUTDOWN_SERVER(){ @@ -245,7 +245,7 @@ SHUTDOWN_SERVER(){ [[ "${PW_HOST_IDRACS[${PW_ESXI_HOST_NAMES[${ESXIHOST}]}]}" = "10.6."* ]] && ESXI_PASS=${PW_ESXI_PASS_KP} || ESXI_PASS=${PW_ESXI_PASS} if [ "${TEST^^}" != "TRUE" ] && [ "${TEST_DONOT_SHUTDOWN^^}" != "TRUE" ]; then if [ "$(ipmitool -I lanplus -H ${PW_HOST_IDRACS[${PW_ESXI_HOST_NAMES[${ESXIHOST}]}]} -U ${PW_ESXI_USER} -P "${ESXI_PASS}" chassis power status | grep 'Power is on')" != "" ]; then - ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${ESXIHOST} "/vmfs/volumes/ESXi-Vault (Fileserver)/!SCRIPTS/esxidown/async.sh" + ${SSHCMD} root@${ESXIHOST} "/vmfs/volumes/ESXi-Vault (Fileserver)/!SCRIPTS/esxidown/async.sh" echo -e "${idsCL[Green]}Command sent${idsCL[Default]}" else echo -e "${idsCL[Yellow]}Host Offline${idsCL[Default]}" @@ -317,7 +317,7 @@ SHUTDOWN_SERVER(){ # c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done # echo -en "${idsCL[White]}${MSG}${MSG_SPC}: " # if [ ${TESTMODE} -eq 0 ]; then - # run=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_VCENTERHOST} "sed -i '//{n;s/.*<\/enabled>/False<\/enabled>/}' /etc/vmware-vpx/vpxd.cfg >/dev/null 2>&1" >/dev/null 2>&1) + # run=$(${SSHCMD} root@${PW_VCENTERHOST} "sed -i '//{n;s/.*<\/enabled>/False<\/enabled>/}' /etc/vmware-vpx/vpxd.cfg >/dev/null 2>&1" >/dev/null 2>&1) # echo -e "${idsCL[Green]}Done${idsCL[Default]}" # touch ${PW_TMPFOLDER}/shutdown.cls.offsite # else @@ -329,7 +329,7 @@ SHUTDOWN_SERVER(){ c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[White]}${MSG}${MSG_SPC}: " if [ ${TESTMODE} -eq 0 ]; then - run=$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_VCENTERHOST} "sed -i '//{n;s/.*<\/enabled>/False<\/enabled>/}' /etc/vmware-vpx/vpxd.cfg >/dev/null 2>&1" >/dev/null 2>&1) + run=$(${SSHCMD} root@${PW_VCENTERHOST} "sed -i '//{n;s/.*<\/enabled>/False<\/enabled>/}' /etc/vmware-vpx/vpxd.cfg >/dev/null 2>&1" >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" touch ${PW_TMPFOLDER}/shutdown.cls.mainsite else @@ -340,7 +340,7 @@ SHUTDOWN_SERVER(){ c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[White]}${MSG}${MSG_SPC}: " if [ ${TESTMODE} -eq 0 ]; then - ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${PW_VCENTERHOST} "service-control --stop vmware-vpxd >/dev/null 2>&1 && service-control --start vmware-vpxd >/dev/null 2>&1" >/dev/null & 2>&1 & + ${SSHCMD} root@${PW_VCENTERHOST} "service-control --stop vmware-vpxd >/dev/null 2>&1 && service-control --start vmware-vpxd >/dev/null 2>&1" >/dev/null & 2>&1 & echo -e "${idsCL[Green]}Continuing in background${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" @@ -397,7 +397,7 @@ SHUTDOWN_SERVER(){ ${PW_FOLDER}/esxi-scripts/iscsi-all-shutdown-verify.ps1 >/dev/null 2>&1 fi echo -e "${idsCL[Green]}Done${idsCL[Default]}" - # if [ "$(ipmitool -I lanplus -H ${PW_HOST_IDRACS[${PW_ESXI_HOST_NAMES[${ESXIHOST}]}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" chassis power status | grep 'Power is on')" != "" ] && [ "$(ssh -q -o ConnectTimeout=3 -o ConnectionAttempts=1 root@${ESXIHOST} 'esxcli system maintenanceMode get')" != "Enabled" ]; then + # if [ "$(ipmitool -I lanplus -H ${PW_HOST_IDRACS[${PW_ESXI_HOST_NAMES[${ESXIHOST}]}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" chassis power status | grep 'Power is on')" != "" ] && [ "$(${SSHCMD} root@${ESXIHOST} 'esxcli system maintenanceMode get')" != "Enabled" ]; then # VERIFY_ISCSI_VM_DOWN "${ESXI_HOST}" & # else # touch ${PW_TMPFOLDER}/verify.iscsi.${ESXIHOST}.done