Update temp.inc.sh

This commit is contained in:
2024-01-09 11:08:04 -06:00
parent d9deb9ea9f
commit dd91c26ba1

View File

@@ -348,7 +348,25 @@ CHECKTEMP_SERVICE_RUNSENSOR(){
unset IFS
[ -f ${PW_TMPFOLDER}/power.${SENSORa}.off ] && [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/power.${SENSORa}.off)) -ge 300 ] && rm-f ${PW_TMPFOLDER}/power.${SENSORa}.off
t=1
####### Fan Issue Workaround #######
if [ ! -f ${PW_TMPFOLDER}/${SENSORa}.down ] && ([ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ] || [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.10.2.27" ]); then
if [ ! -f ${PW_TMPFOLDER}/.fancheck ] || [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/.fancheck)) -ge 300 ]; then
# vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSORa}]} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.3 -O vq)
vHOSTFAN=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${SENSORa}]} -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan3" 2>&1)
if [ "${vHOSTFAN}" != "" ]; then
# FanSpeed=`echo "scale=2; ${vHOSTFAN}/21200" | bc`; FanSpeed=$(ROUND_NUMBER `echo "scale=0; ${FanSpeed}*100" | bc | sed -e 's/.00//g'` 0)
if [ "$(echo ${vHOSTFAN} | awk '/ / {print $4}' | sed -e 's/%//g')" == "RPM" ]; then
FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $9}' | sed -e 's/%//g')
else
FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g')
fi
else
FanSpeed=''
fi
fi
fi
else
SENSORS_CHECK=(${SENSORa})
fi
@@ -474,22 +492,6 @@ CHECKTEMP_SERVICE_RUNSENSOR(){
echo ${PW_THRESHOLDS[${SENSOR}]} | cut -d',' -f 2 | read temp_crit
echo ${PW_THRESHOLDS[${SENSOR}]} | cut -d',' -f 3 | read temp_crit_sys
fi
####### Fan Issue Workaround #######
# if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ] || [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.10.2.27" ]; then
# # vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSORa}]} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.3 -O vq)
# vHOSTFAN=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${SENSORa}]} -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan3" 2>&1)
# if [ "${vHOSTFAN}" != "" ]; then
# # FanSpeed=`echo "scale=2; ${vHOSTFAN}/21200" | bc`; FanSpeed=$(ROUND_NUMBER `echo "scale=0; ${FanSpeed}*100" | bc | sed -e 's/.00//g'` 0)
# if [ "$(echo ${vHOSTFAN} | awk '/ / {print $4}' | sed -e 's/%//g')" == "RPM" ]; then
# FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $9}' | sed -e 's/%//g')
# else
# FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g')
# fi
# else
# FanSpeed=''
# fi
# fi
if [[ "${SENSORa}" != *"-Usage"* ]] && (( $(bc <<< "${temp_f} < ${temp_warn}") )); then
if (( $(bc <<< "${last_temp} >= 1") )); then
@@ -519,16 +521,18 @@ CHECKTEMP_SERVICE_RUNSENSOR(){
fi
####### Fan Issue Workaround #######
# if [ "${FanSpeed}" != "" ] && ([ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ] || [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.10.2.27" ]); then
# # if [ ${FanSpeed} -lt 26 ] || [ ${FanSpeed} -gt 34 ]; then
# if [ ${FanSpeed} -ne 30 ]; then
# SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} Fan Issue" "Settings fans back to normal 30%"
# ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00 >/dev/null 2>&1
# ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0x1E >/dev/null 2>&1
# echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${FanSpeed}% - ${SENSOR} - Resetting FanSpeed back to 30%" >> ${logtemp}
# echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${FanSpeed}% - ${SENSOR} - Resetting FanSpeed back to 30%" >> ${PW_LOGFILE}
# fi
# fi
if [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "esxi" ] && [ ! -f ${PW_TMPFOLDER}/${SENSORa}.down ] && [ "${FanSpeed}" != "" ] && ([ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ] || [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.10.2.27" ]) && [ "${SENSOR}" == "CPU1" ]; then
if [ ! -f ${PW_TMPFOLDER}/.fancheck ] || [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/.fancheck)) -ge 300 ]; then
# if [ ${FanSpeed} -lt 26 ] || [ ${FanSpeed} -gt 34 ]; then
if [ ${FanSpeed} -ne 30 ]; then
SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} Fan Issue" "Settings fans back to normal 30%"
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00 >/dev/null 2>&1
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0x1E >/dev/null 2>&1
echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${FanSpeed}% - ${SENSOR} - Resetting FanSpeed back to 30%" >> ${logtemp}
echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${FanSpeed}% - ${SENSOR} - Resetting FanSpeed back to 30%" >> ${PW_LOGFILE}
fi
fi
fi
elif [[ "${SENSORa}" != *"-Usage"* ]]; then
@@ -666,6 +670,7 @@ CHECKTEMP_SERVICE_RUNSENSOR(){
fi
fi
done
[ ! -f ${PW_TMPFOLDER}/.fancheck ] || [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/.fancheck)) -ge 300 ] && touch ${PW_TMPFOLDER}/.fancheck
fi
else