Update powerwall.sh
This commit is contained in:
21
powerwall.sh
21
powerwall.sh
@@ -477,7 +477,7 @@ HOSTMGMT(){
|
|||||||
DIVIDER . yellow 75
|
DIVIDER . yellow 75
|
||||||
|
|
||||||
HOST=${1}
|
HOST=${1}
|
||||||
if [ "${HOST}" != "-h" ] && [ "${HOST}" != "" ]; then
|
if [ "${HOST,,}" != "-s" ] && [ "${HOST,,}" != "-status" ] && [ "${HOST,,}" != "-h" ] && [ "${HOST,,}" != "-help" ] && [ "${HOST}" != "" ]; then
|
||||||
cHOST=${HOST}
|
cHOST=${HOST}
|
||||||
MN=0
|
MN=0
|
||||||
if [ "${PW_iDRACHOST_SHORTNAMES[${HOST}]}" != "" ]; then
|
if [ "${PW_iDRACHOST_SHORTNAMES[${HOST}]}" != "" ]; then
|
||||||
@@ -515,12 +515,20 @@ HOSTMGMT(){
|
|||||||
idracip=${PW_HOST_IDRACS[${tmp}]}
|
idracip=${PW_HOST_IDRACS[${tmp}]}
|
||||||
hostname=${PW_iDRACHOST_SHORTNAMES[${idracip}]}
|
hostname=${PW_iDRACHOST_SHORTNAMES[${idracip}]}
|
||||||
fi
|
fi
|
||||||
|
|
||||||
|
elif [ "${HOST,,}" == "-s" ] && [ "${HOST,,}" == "-status" ]; then
|
||||||
|
for ESXIHOST in "${PW_ALLHOSTS[@]}"; do
|
||||||
|
echo ${ESXIHOST}
|
||||||
|
done
|
||||||
|
|
||||||
|
exit 0
|
||||||
else
|
else
|
||||||
echo -e "Usage: ${idsCL[Yellow]}pw host {host} {flags}${idsCL[Default]} {"
|
echo -e "Usage: ${idsCL[Yellow]}pw host {host} {flags}${idsCL[Default]} {"
|
||||||
width=35
|
width=35
|
||||||
printf "%-${width}s- %s\n" " {host}" "(*required, can either be esxiIP,idracIP or Host#)"
|
printf "%-${width}s- %s\n" " {host}" "(*required if not uing -s, can either be esxiIP,idracIP or Host#)"
|
||||||
printf "%-${width}s- %s\n" " -p|-power {on / off}" "Controls Host Power"
|
printf "%-${width}s- %s\n" " -p|-power {on / off}" "Controls Host Power"
|
||||||
printf "%-${width}s- %s\n" " -e|-esxi {off / mm}" "Shuts down ESXi or puts into maintenance mode"
|
printf "%-${width}s- %s\n" " -e|-esxi {off / mm}" "Shuts down ESXi or puts into maintenance mode"
|
||||||
|
printf "%-${width}s- %s\n" " -s|-status" "List all Host's Status"
|
||||||
echo -e "}\n"
|
echo -e "}\n"
|
||||||
exit 0
|
exit 0
|
||||||
fi
|
fi
|
||||||
@@ -528,15 +536,6 @@ HOSTMGMT(){
|
|||||||
case "$1" in
|
case "$1" in
|
||||||
-p|-power) POWER=${2}; MODE="power";;
|
-p|-power) POWER=${2}; MODE="power";;
|
||||||
-e|-esxi) ESXI=${2}; MODE="esxi";;
|
-e|-esxi) ESXI=${2}; MODE="esxi";;
|
||||||
-h|-help)
|
|
||||||
echo -e "Usage: ${idsCL[Yellow]}pw host {host} {flags}${idsCL[Default]} {"
|
|
||||||
width=35
|
|
||||||
printf "%-${width}s- %s\n" " {host}" "(*required, can either be esxiIP,idracIP or Host#)"
|
|
||||||
printf "%-${width}s- %s\n" " -p|-power {on / off}" "Controls Host Power"
|
|
||||||
printf "%-${width}s- %s\n" " -e|-esxi {off / mm}" "Shuts down ESXi or puts into maintenance mode"
|
|
||||||
echo -e "}\n"
|
|
||||||
exit 0
|
|
||||||
;;
|
|
||||||
esac
|
esac
|
||||||
shift 1
|
shift 1
|
||||||
done
|
done
|
||||||
|
|||||||
Reference in New Issue
Block a user