AVERAGEPOWER(){ watttotal=0 sensorid=${1} daysback=${2} logsfound=0; while IFS=$'\t' read date watt ;do watttotal=$(bc <<< "scale=2; ${watttotal}+${watt}") ((logsfound++)) done < <(${mysql_conn} -se "USE servermonitor; SELECT date,watt from power_data WHERE sensorid=${sensorid} AND date BETWEEN DATE_SUB(DATE(NOW()), INTERVAL ${daysback} DAY) AND NOW() ORDER BY id DESC;") [ "${logsfound}" != "0" ] && average=$(bc <<< "scale=2; ${watttotal}/${logsfound}") || average=0 # echo "$watttotal-$logsfound=${average}" # echo "${average}-(${logsfound})" echo ${average} } CHECKPOWER(){ start=`date +%s` rm -f ${PW_TMPFOLDER}/*.hostpower* while [ $# -gt 0 ]; do case "$1" in -a|-avg) avgdays=${2};; -o|-offsite) STYPE=offsite;; -m|-mainsite) STYPE=mainsite;; -e|-esxi) PTYPE=esxi;; -p|-power) PTYPE=power;; esac shift 1 done [ "${avgdays}" == "0" ] && unset avgdays [ "${avgdays}" != "" ] && avgdayshdr="${avgdays}-Day-Avg" || avgdayshdr="" if ([ "${STYPE}" == "" ] || [ "${STYPE}" == "mainsite" ]) && [ "${PTYPE}" != "esxi" ]; then echo DIVIDER . yellow 75 echo -e "${idsCL[Yellow]}Mainsite Power Information ${idsCL[LightYellow]}${avgdayshdr}" DIVIDER . yellow 75 echo -en "${idsCL[Yellow]}Pulling data from 'Powerwall' ... " INVSTATSINFO=$(curl -s "http://${PW_INVERTER_IP}/stats.json") if [ "${INVSTATSINFO}" != "" ]; then INPUTV=`echo ${INVSTATSINFO} | jq '.inputs .inV'` INPUTA=`echo ${INVSTATSINFO} | jq '.inputs .inA'` INV_ALARM=`echo ${INVSTATSINFO} | jq '.errors .Alms'` [ "${INV_ALARM}" == "0" ] && INV_ALARM_disp="${idsCL[Green]}No Alarms (${INV_ALARM})" || INV_ALARM_disp="${idsCL[LightRed]}${PW_INVERTER_ALARMS[${INV_ALARM}]}" INV_ERROR=`echo ${INVSTATSINFO} | jq '.errors .Err'` [ "${INV_ERROR}" == "0" ] && INV_ERROR_disp="${idsCL[Green]}No Errors (${INV_ERROR})" || INV_ERROR_disp="${idsCL[LightRed]}${PW_INVERTER_ERRORS[${INV_ERROR}]}" INV_STATE=`echo ${INVSTATSINFO} | jq '.stats .invSTATES'` [ "${INV_STATE}" != "0" ] && INV_STATE_disp="${idsCL[Green]}${PW_INVERTER_STATES[${INV_STATE}]}" || INV_STATE_disp="${idsCL[LightRed]}${PW_INVERTER_STATES[${INV_STATE}]}" INV_MODE=`echo ${INVSTATSINFO} | jq '.stats .power'` ([ "${INV_MODE}" != "3" ] && [ "${INV_MODE}" != "4" ] && [ "${INV_MODE}" != "E" ]) && INV_MODE_disp="${idsCL[Green]}${PW_INVERTER_MODES[${INV_MODE}]}" || INV_MODE_disp="${idsCL[LightRed]}${PW_INVERTER_MODES[${INV_MODE}]}" OUTPUTV=`echo ${INVSTATSINFO} | jq '.outputs .outV'` OUTPUTV2=`echo "scale=2; ${OUTPUTV}/2" | bc` OUTPUTA=`echo ${INVSTATSINFO} | jq '.outputs .outA'` OUTPUTA2=`echo "scale=2; ${OUTPUTA}*2" | bc` OUTPUTW=`echo ${INVSTATSINFO} | jq '.outputs .outW'` BATTV=`echo ${INVSTATSINFO} | jq '.inputs .battV'` BATTA=`echo ${INVSTATSINFO} | jq '.inputs .xfA'` BATTLIFE=`echo "scale=2; (${BATTV}*100)/${BATT_FULL}" | bc` if (( $(bc <<<"${BATTV} > ${FLOAT_CHARGE}") )); then if (( $(bc <<<"${BATTV} > ${BULK_CHARGE}") )); then BATTA_disp="${idsCL[Green]}`IDS_NUMBER_FORMAT ${BATTA}`'amps ${idsCL[LightCyan]}- Bulk Charging" else BATTA_disp="${idsCL[Green]}`IDS_NUMBER_FORMAT ${BATTA}`'amps ${idsCL[LightCyan]}- Float Charging" fi elif [ "${BATTA}" == "-0.1" ] || [ "${BATTA}" == "-0.2" ] || [ "${BATTA}" == "-0.3" ]; then BATTA_disp="${idsCL[LightCyan]}`IDS_NUMBER_FORMAT ${BATTA}`'amps ${idsCL[LightCyan]}- Standby" else BATTA_disp="${idsCL[LightRed]}`IDS_NUMBER_FORMAT ${BATTA}`'amps ${idsCL[LightCyan]}- Discharging" fi fi echo -en "\r\033[K" echo -e "${idsCL[White]}Inverter State ${idsCL[Default]}: ${INV_STATE_disp}" echo -e "${idsCL[White]}Inverter Mode ${idsCL[Default]}: ${INV_MODE_disp}" echo -e "${idsCL[White]}Inverter Alarms ${idsCL[Default]}: ${INV_ALARM_disp}" echo -e "${idsCL[White]}Inverter Errors ${idsCL[Default]}: ${INV_ERROR_disp}" echo echo -e "${idsCL[White]}Inverter Input Volts ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${INPUTV}`'volts" echo -e "${idsCL[White]}Inverter Input Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${INPUTA}`'amps" echo echo -e "${idsCL[White]}Inverter Output Volts ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OUTPUTV}`'volts / `IDS_NUMBER_FORMAT ${OUTPUTV2}`'volts" echo -e "${idsCL[White]}Inverter Output Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OUTPUTA}`'amps / `IDS_NUMBER_FORMAT ${OUTPUTA2}`'amps" echo -e "${idsCL[White]}Inverter Output Watts ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OUTPUTW}`'watts" echo echo -e "${idsCL[White]}Battery Voltage ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${BATTV}`'volts ~ `IDS_NUMBER_FORMAT ${BATTLIFE}`%" echo -e "${idsCL[White]}Battery Amps Chg/DChg ${idsCL[Default]}: ${BATTA_disp}${idsCL[Default]}" # echo DIVIDER . lightCyan 75 echo -en "${idsCL[Yellow]}Pulling data from 'ServerRoom' ... " # if [ "$(CHECK_HOST ${PW_UPS_IP})" != "false" ]; then SVRRM_VOLTIN=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.2.2.1.3.1.1 | sed 's/.*: //') SVRRM_VOLTIN=`echo "scale=2; ${SVRRM_VOLTIN}/10" | bc` SVRRM_VOLTOUT=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.3.2.1.2.1.1 | sed 's/.*: //') SVRRM_VOLTOUT=`echo "scale=2; ${SVRRM_VOLTOUT}/10" | bc` SVRRM_WATT=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.3.2.1.4.1.1 | sed 's/.*: //') SVRRM_AMP=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.3.2.1.3.1.1 | sed 's/.*: //') SVRRM_AMP=`echo "scale=2; ${SVRRM_AMP}/100" | bc` # fi # # if [ "$(CHECK_HOST ${PW_APCPDU_IP})" != "false" ]; then APCPDU_AMP=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.2.3.1.1.2.1 | sed 's/.*: //') APCPDU_AMP=`echo "scale=2; ${APCPDU_AMP}/10" | bc` APCPDU_WATT2=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.1.16.0 | sed 's/.*: //') APCPDU_WATT=`echo "scale=2; ${APCPDU_AMP}*${SVRRM_VOLTOUT}" | bc` # fi if [ "${SVRRM_VOLTOUT}" != "" ]; then if [ "${APCPDU_AMP}" != "" ]; then NETRK_AMP=`echo "scale=2; ${SVRRM_AMP}-${APCPDU_AMP}" | bc` NETRK_WATT=`echo "scale=2; ${SVRRM_WATT}-${APCPDU_WATT}" | bc` NETRK_WATT2=`echo "scale=2; ${SVRRM_WATT}-${APCPDU_WATT2}" | bc` fi VOLT_DROP=`echo "scale=1; ${OUTPUTV2}-${SVRRM_VOLTIN}" | bc` fi echo -en "\r\033[K" echo -e "${idsCL[White]}ServerRack Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${APCPDU_AMP}`'amps${idsCL[Default]}" MSG="${idsCL[White]}ServerRack Wattage ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${APCPDU_WATT}`'watts ${idsCL[Default]}~ estimate" echo -en "${MSG}" if [ "${avgdays}" != "" ]; then echo -en "${idsCL[LightYellow]} Calculating average ...${idsCL[Default]}" average=$(AVERAGEPOWER ${PW_POWERSENSOR_ID['server-rack']} ${avgdays}); average_disp="${idsCL[LightYellow]} `IDS_NUMBER_FORMAT ${average}`'watts" echo -en "\r\033[K"; echo -en "${MSG}${idsCL[LightYellow]}${average_disp}" else echo -en " ${idsCL[LightCyan]}(`IDS_NUMBER_FORMAT ${APCPDU_WATT2}` watts)" fi echo -e "${idsCL[Default]}" DIVIDER . lightCyan 75 echo -e "${idsCL[White]}NetworkRack Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${NETRK_AMP}`'amps ${idsCL[Default]}~ estimate${idsCL[Green]}${idsCL[Default]}" MSG="${idsCL[White]}NetworkRack Wattage ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${NETRK_WATT} 2 true`'watts ${idsCL[Default]}~ estimate" echo -en "${MSG}" if [ "${avgdays}" != "" ]; then echo -en "${idsCL[LightYellow]} Calculating average ...${idsCL[Default]}" average=$(AVERAGEPOWER ${PW_POWERSENSOR_ID['network-rack']} ${avgdays}); average_disp="${idsCL[LightYellow]} `IDS_NUMBER_FORMAT ${average}`'watts" echo -en "\r\033[K"; echo -en "${MSG}${idsCL[LightYellow]}${average_disp}" else echo -en " ${idsCL[LightCyan]}(`IDS_NUMBER_FORMAT ${NETRK_WATT2}` watts)" fi echo -e "${idsCL[Default]}" # echo DIVIDER . lightCyan 75 echo -e "${idsCL[White]}Server Room Voltage IN ${idsCL[Default]}: ${idsCL[Green]}${SVRRM_VOLTIN}'volts${idsCL[Default]}" echo -e "${idsCL[White]}Server Room Voltage OUT ${idsCL[Default]}: ${idsCL[Green]}${SVRRM_VOLTOUT}'volts${idsCL[Default]}" echo -e "${idsCL[LightCyan]}Voltage Drop ${idsCL[Default]}: ${idsCL[LightRed]}${VOLT_DROP}'volts${idsCL[Default]}" echo -e "${idsCL[White]}Server Room Amps ${idsCL[Default]}: ${idsCL[Green]}${SVRRM_AMP}'amps${idsCL[Default]}" MSG="${idsCL[White]}Server Room Wattage ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${SVRRM_WATT}`'watts" echo -en "${MSG}" if [ "${avgdays}" != "" ]; then echo -en "${idsCL[LightYellow]} Calculating average ...${idsCL[Default]}" average=$(AVERAGEPOWER ${PW_POWERSENSOR_ID['total']} ${avgdays}); average_disp="${idsCL[LightYellow]} `IDS_NUMBER_FORMAT ${average}`'watts" echo -en "\r\033[K"; echo -e "${MSG}${idsCL[LightYellow]}${average_disp}${idsCL[Default]}" else echo -e "${idsCL[Default]}" fi echo fi if ([ "${STYPE}" == "" ] || [ "${STYPE}" == "offsite" ]) && [ "${PTYPE}" != "esxi" ]; then DIVIDER . yellow 75 echo -e "${idsCL[Yellow]}Offsite Power Information ${idsCL[LightYellow]}${avgdayshdr}" DIVIDER . yellow 75 echo -en "${idsCL[Yellow]}Pulling data from 'Offsite' ... " upsinfo=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 admin@10.2.1.1 'upsc CP1500PFCLCD') if [ "$(echo "${upsinfo}" | grep 'input.voltage:')" != "" ]; then OFFSITE_VOLTIN=$(echo "${upsinfo}" | grep 'input.voltage:' | sed 's/.*: //') OFFSITE_VOLTOUT=$(echo "${upsinfo}" | grep 'output.voltage:' | sed 's/.*: //') OFFSITE_LOAD=$(echo "${upsinfo}" | grep 'ups.load:' | sed 's/.*: //') OFFSITE_LOAD=`echo "scale=2; ${OFFSITE_LOAD}/100" | bc` OFFSITE_WATTS=`echo "scale=2; ${OFFSITE_LOAD}*$(echo "${upsinfo}" | grep 'ups.realpower.nominal:' | sed 's/.*: //')" | bc` OFFSITE_AMPS=`echo "scale=2; ${OFFSITE_WATTS}/${OFFSITE_VOLTOUT}" | bc` (( $(bc <<<"${OFFSITE_AMPS} < 1") )) && [[ "${OFFSITE_AMPS}" = *"."* ]] && OFFSITE_AMPS="0${OFFSITE_AMPS}" OFFSITE_BATT_RUNTIME=$(echo "${upsinfo}" | grep 'battery.runtime:' | sed 's/.*: //') OFFSITE_BATT_RUNTIME=`echo "scale=2; ${OFFSITE_BATT_RUNTIME}/60" | bc` OFFSITE_BATT_CAP=$(echo "${upsinfo}" | grep 'battery.charge:' | sed 's/.*: //') # vHOSTFAN=$(ssh root@${PW_RACADM_ACCESS} racadm -r 10.2.1.21 -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1) # FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g') # OFFSITE_VOLTIN=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.4.1.3808.1.1.1.3.2.1.0 | sed 's/.*: //') # OFFSITE_VOLTIN=`echo "scale=2; ${OFFSITE_VOLTIN}/10" | bc` # OFFSITE_VOLTOUT=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.4.1.3808.1.1.1.4.2.1.0 | sed 's/.*: //') # OFFSITE_VOLTOUT=`echo "scale=2; ${OFFSITE_VOLTOUT}/10" | bc` # OFFSITE_LOAD=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.4.1.3808.1.1.1.4.2.3.0 | sed 's/.*: //') # OFFSITE_LOAD=`echo "scale=2; ${OFFSITE_LOAD}/100" | bc` # OFFSITE_WATTS=`echo "scale=2; ${OFFSITE_LOAD}*900" | bc` # OFFSITE_AMPS=`echo "scale=2; ${OFFSITE_WATTS}/${OFFSITE_VOLTOUT}" | bc` # OFFSITE_BATT_RUNTIME=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.2.1.33.1.2.3.0 | sed 's/.*: //') # OFFSITE_BATT_CAP=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.2.1.33.1.2.4.0 | sed 's/.*: //') fi echo -en "\r\033[K" echo -e "${idsCL[White]}UPS Voltage In ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OFFSITE_VOLTIN}`'volts${idsCL[Default]}" echo -e "${idsCL[White]}UPS Voltage Out ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OFFSITE_VOLTOUT}`'volts${idsCL[Default]}" echo echo -e "${idsCL[White]}Battery Capacity ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OFFSITE_BATT_CAP}`%${idsCL[Default]}" echo -e "${idsCL[White]}Battery Runtime ${idsCL[Default]}: ${idsCL[Green]}${OFFSITE_BATT_RUNTIME}'Mins${idsCL[Default]}" echo echo -e "${idsCL[White]}Total Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OFFSITE_AMPS}`'amps ${idsCL[Default]}~ estimate${idsCL[Green]}${idsCL[Default]}" MSG="${idsCL[White]}Total Wattage ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OFFSITE_WATTS}`'watts ${idsCL[Default]}~ estimate" echo -en "${MSG}" if [ "${avgdays}" != "" ]; then echo -en "${idsCL[LightYellow]} Calculating average ...${idsCL[Default]}" average=$(AVERAGEPOWER ${PW_POWERSENSOR_ID['offsite-ups']} ${avgdays}); average_disp="${idsCL[LightYellow]} `IDS_NUMBER_FORMAT ${average}`'watts" echo -en "\r\033[K"; echo -e "${MSG}${idsCL[LightYellow]}${average_disp}" fi echo -e "${idsCL[Default]}\n" # echo -e "${idsCL[LightCyan]}Current Fan Speed ${idsCL[Default]}: ${idsCL[Green]}${FanSpeed}'%${idsCL[Default]}" # echo fi if [ "${PTYPE}" != "power" ]; then DIVIDER . yellow 75 echo -e "${idsCL[Yellow]}ESXi Host Power Information ${avgdayshdr}" DIVIDER . yellow 75 for SENSOR in ${PW_SENSOR_ORD[@]}; do if [ "${PW_HOST_IDRACS[${SENSOR}]}" != "" ]; then gochk=0 if [ "${STYPE}" == "" ] || ([ "${STYPE}" == "mainsite" ] && [[ "${PW_HOST_IDRACS[${SENSOR}]}" = *"10.10."* ]]) || ([ "${STYPE}" == "offsite" ] && [[ "${PW_HOST_IDRACS[${SENSOR}]}" = *"10.2.1."* ]]); then gochk=1 fi if [ ${gochk} -eq 1 ]; then echo -en "${idsCL[Yellow]}Pulling data for '${SENSOR}' ... " HOST_WATT_SENSORS=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.8.1 -O vq 2> /dev/null | sed -e 's/"//g') IFS=$'\n' read -rd '' -a HOST_WATT_SENSORS <<<"${HOST_WATT_SENSORS}" unset IFS PS1='0.0'; PS2='0.0'; HOST_WATTS=0 if [ "${HOST_WATT_SENSORS}" != "" ]; then found=0 for s in {1..5}; do DP=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.8.1.${s} | sed 's/.*: //') if [[ "${DP}" = *"System Board"* ]]; then found=1 HOST_WATTS=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.6.1.${s} | sed 's/.*: //') elif [[ "${DP}" = *"PS1"* ]]; then PS1=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.6.1.${s} | sed 's/.*: //') elif [[ "${DP}" = *"PS2"* ]]; then PS2=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.6.1.${s} | sed 's/.*: //') fi done if [ ${found} -eq 1 ] && [ "${HOST_WATTS}" != "0" ] && [ "${HOST_WATTS}" != "" ]; then [ "${PS1}" != "0.0" ] && PS1=`echo "scale=1; ${PS1}/10" | bc` && (( $(bc <<<"${PS1} < 1") )) && [[ "${PS1}" = *"."* ]] && PS1="0${PS1}" [ "${PS2}" != "0.0" ] && PS2=`echo "scale=1; ${PS2}/10" | bc` && (( $(bc <<<"${PS2} < 1") )) && [[ "${PS2}" = *"."* ]] && PS2="0${PS2}" HOST_AMPS=`echo "scale=1; ${PS1}+${PS2}" | bc` HOST_WATTS_disp="${idsCL[Green]}${HOST_AMPS}'amps - `IDS_NUMBER_FORMAT ${HOST_WATTS}`'watts" elif [ "$(ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSOR}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" chassis power status | grep off)" != "" ]; then HOST_WATTS_disp="${idsCL[LightRed]}Host powered down" HOST_WATTS=-1 elif [ "${HOST_WATTS}" == "0" ]; then HOST_WATTS_disp="${idsCL[Yellow]}Host PSU not capable" else HOST_WATTS_disp="${idsCL[LightRed]}Could not pull data" fi [ "${HOST_WATTS}" == "" ] && HOST_WATTS=0 else HOST_WATTS_disp="${idsCL[LightRed]}Host offline" fi MSG="${idsCL[White]}${SENSOR} ${idsCL[Default]}: ${HOST_WATTS_disp}" echo -en "\r\033[K${MSG}" if [ "${HOST_WATT_SENSORS}" != "" ]; then if [ "${avgdays}" != "" ] && [ ${HOST_WATTS} -gt 0 ]; then echo -en "${idsCL[LightYellow]} Calculating average ...${idsCL[Default]}" average=$(AVERAGEPOWER ${PW_POWERSENSOR_ID[${SENSOR}]} ${avgdays}); average_disp="${idsCL[LightYellow]} `IDS_NUMBER_FORMAT ${average}`'watts" echo -en "\r\033[K"; echo -en "${MSG}${idsCL[LightYellow]}${average_disp}" elif [ ${HOST_WATTS} -gt 0 ]; then echo -en "${idsCL[Cyan]} [PS1=${idsCL[LightCyan]}${PS1}'A${idsCL[Cyan]}, PS2=${idsCL[LightCyan]}${PS2}'A${idsCL[Cyan]}]" fi if [ "${PW_HOST_IDRACS[${SENSOR}]}" == "10.2.1.21" ] && [ ${HOST_WATTS} -ge 0 ]; then vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSOR}]} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.3 -O vq) FanSpeed=`echo "scale=2; ${vHOSTFAN}/21200" | bc`; FanSpeed=`echo "scale=0; ${FanSpeed}*100/1" | bc` # vHOSTFAN=$(ssh root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${SENSOR}]} -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1) # FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g') echo -en "${idsCL[LightCyan]} [FanSpeed=${FanSpeed}'%]" fi fi echo -e "${idsCL[Default]}" fi fi done fi end=`date +%s`; runtime=$((end-start)); echo -e "\nruntime: ${runtime}" [ "${PW_ACTION}" != "" ] && echo } CHECKPOWER_SERVICE(){ touch ${PW_TMPFOLDER}/power.ac.start touch ${PW_TMPFOLDER}/power.dc.start while true; do INVSTATSINFO=$(curl -s "http://${PW_INVERTER_IP}/stats.json") SVRRM_UPS_INPUTACV=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.2.2.1.3.1.1 | sed 's/.*: //') if (( $(bc <<<"${SVRRM_UPS_INPUTACV} < ${min_acvolt}") )); then if [ ! -f ${PW_TMPFOLDER}/power.ups.low ]; then touch ${PW_TMPFOLDER}/power.ups.low elif [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/power.ups.low)) -ge 60 ]; then SENDNOTICE "POWER ALERT - UPS POWER OFF/LOW POWER!!" "UPS has no power for 1min, shutting all servers down!" 1 ######################### FINISH fi elif [ -f ${PW_TMPFOLDER}/power.ups.low ]; then rm -f ${PW_TMPFOLDER}/power.ups.low fi if [ "${INVSTATSINFO}" != "" ]; then INPUTACV=$(echo ${INVSTATSINFO} | jq '.inputs .inV') BATTVOLT=$(echo ${INVSTATSINFO} | jq '.inputs .battV') [ ! "${last_battvolt}" ] && last_battvolt=${BATTVOLT} if (( $(bc <<<"${INPUTACV} >= ${min_acvolt}") )); then [ "${last_battvolt}" != "${BATTVOLT}" ] && last_battvolt=${BATTVOLT} if [ -f ${PW_TMPFOLDER}/power.ac.low ]; then echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${INPUTACV}'volts / ${BATTVOLT}'volts - Back to Normal Voltage" >> ${PW_LOGPOWER} SENDNOTICE "POWER NOMINAL AGAIN" "Normal voltage detected VOLTAGE: ${INPUTACV}'volts" else [ $(expr `date +%s` - $(stat -c %Y ${PW_LOGPOWER})) -ge $(echo "scale=0; ${PW_LOG_INTERVAL_NORMAL}*60" | bc) ] && echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${INPUTACV}'volts - Normal Voltage" >> ${PW_LOGPOWER} if [ -f ${PW_TMPFOLDER}/power.ac.start ]; then SENDNOTICE "Power Nominal" "Service Startup Normal voltage detected VOLTAGE: ${INPUTACV}'volts BATT VOLTAGE: ${BATTVOLT}'volts" echo "($(date +'%Y-%m-%d %H:%M:%S')) - Input: ${INPUTACV}'volts - 'Check Power' Service Startup - Normal voltage detected" >> ${PW_LOGFILE} echo "($(date +'%Y-%m-%d %H:%M:%S')) - Input: ${INPUTACV}'volts - 'Check Power' Service Startup - Normal voltage detected" >> ${PW_LOGPOWER} rm -f ${PW_TMPFOLDER}/power.ac.start fi fi if [ ! -f ${PW_TMPFOLDER}/power.ac.good ]; then if [ -f ${PW_TMPFOLDER}/shutdown.SYS ] || [ -f ${PW_TMPFOLDER}/shutdown.MAIN ] || [ -f ${PW_TMPFOLDER}/power.ac.conserve ]; then SENDNOTICE "HOSTS POWER" "Power restored! Will wait ${PW_WAIT_TO_POWER_SERVERS}'mins before turning host(s) back on" touch ${PW_TMPFOLDER}/.power.restored fi rm -f ${PW_TMPFOLDER}/power.ac.* touch ${PW_TMPFOLDER}/power.ac.good elif [ -f ${PW_TMPFOLDER}/.power.restored ] && [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/.power.restored)) -ge $(echo "scale=0; ${PW_WAIT_TO_POWER_SERVERS}*60" | bc) ]; then HOSTMGMT mainsite -p on >/dev/null 2>&1 rm -f ${PW_TMPFOLDER}/.power.restored fi # UPDATE APC-PDU LINE TO LINE VOLTAGE CURRENT_VOLTAGE=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.1.15.0 | sed 's/.*: //') SET_VOLTAGE=`echo "scale=2; $(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.3.2.1.2.1.1 | sed 's/.*: //')/10" | bc | awk '{print int($1+0.5)}'` [ "${SET_VOLTAGE}" ] && [ ${CURRENT_VOLTAGE} -ne ${SET_VOLTAGE} ] && run=$(snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.1.15.0 i ${SET_VOLTAGE} >/dev/null 2>&1) && echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${CURRENT_VOLTAGE}'volts --> ${SET_VOLTAGE}'volts - LINE-TO-LINE VOLTAGE UPDATED ON APC-PDU" >> ${PW_LOGPOWER} else [ $(expr `date +%s` - $(stat -c %Y ${PW_LOGPOWER})) -ge 300 ] && echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${INPUTACV}'volts / ${BATTVOLT}'volts - Power OFF or LOW" >> ${PW_LOGPOWER} if [ -f ${PW_TMPFOLDER}/power.ac.good ]; then echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${INPUTACV}'volts / ${BATTVOLT}'volts - Power OFF or LOW voltage detected" >> ${PW_LOGPOWER} SENDNOTICE "POWER ALERT - POWER OFF/LOW!!" "Power off or low voltage detected VOLTAGE: ${INPUTACV}'volts BATT VOLTAGE: ${BATTVOLT}'volts" 1 rm -f ${PW_TMPFOLDER}/power.ac.good touch ${PW_TMPFOLDER}/power.ac.low fi # if [ ! -f ${PW_TMPFOLDER}/power.ac.conserve ] && [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/power.ac.low)) -ge $(echo "scale=0; ${PW_CONSERVE_AFTER}*60" | bc) ]; then if [ ! -f ${PW_TMPFOLDER}/power.ac.conserve ] && [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/power.ac.low)) -ge 30 ]; then echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${INPUTACV}'volts / ${BATTVOLT}'volts - Shutting down iSCSI VM's and Host to conserve power" >> ${PW_LOGPOWER} SENDNOTICE "POWER ALERT - Conserving Power" "Shutting down iSCSI VM's and Host to conserve power" 1 SHUTDOWN_SERVER ${PW_MAIN_ISCSI} -esxi off & touch ${PW_TMPFOLDER}/power.ac.conserve fi fi if (( $(bc <<<"${BATTVOLT} >= ${min_battvolt}") )); then [ $(expr `date +%s` - $(stat -c %Y ${PW_LOGPOWER})) -ge $(echo "scale=0; ${PW_LOG_INTERVAL_NORMAL}*60" | bc) ] && echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - Battery Voltage" >> ${PW_LOGPOWER} if [ -f ${PW_TMPFOLDER}/power.dc.start ]; then echo "($(date +'%Y-%m-%d %H:%M:%S')) - Battery: ${BATTVOLT}'volts - Service Startup - Normal voltage detected" >> ${PW_LOGPOWER} rm -f ${PW_TMPFOLDER}/power.dc.start fi if [ ! -f ${PW_TMPFOLDER}/power.dc.good ]; then rm -f ${PW_TMPFOLDER}/power.dc.* touch ${PW_TMPFOLDER}/power.dc.good fi else [ -f ${PW_TMPFOLDER}/power.dc.good ] && rm -f ${PW_TMPFOLDER}/power.dc.good [ $(expr `date +%s` - $(stat -c %Y ${PW_LOGPOWER})) -ge $(echo "scale=0; ${PW_LOG_INTERVAL_ABNORMAL}*60" | bc) ] && echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - LOW BATTERY Voltage" >> ${PW_LOGPOWER} if (( $(bc <<<"${BATTVOLT} <= ${min_battvolt_sys}") )); then [ ! -f ${PW_TMPFOLDER}/power.dc.critlow ] && touch ${PW_TMPFOLDER}/power.dc.critlow if [ ! -f ${PW_TMPFOLDER}/shutdown.SYS.started ] && [ ! -f ${PW_TMPFOLDER}/shutdown.MAINSITE.started ] && (( $(bc <<<"${INPUTACV} < ${min_acvolt}") )); then echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - Shutting down all remaining servers..." >> ${PW_LOGFILE} echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - Shutting down all remaining servers..." >> ${PW_LOGPOWER} SENDNOTICE "BATT-VOLT REALLY LOW: SHUTDOWN SYS SERVERS" "Battery Voltage REALLY LOW: ${BATTVOLT}'volts Shutting down all remaining servers" 1 SHUTDOWN_SYS POWER & fi elif (( $(bc <<<"${BATTVOLT} < ${min_battvolt}") )); then [ ! -f ${PW_TMPFOLDER}/power.dc.low ] && touch ${PW_TMPFOLDER}/power.dc.low if [ ! -f ${PW_TMPFOLDER}/shutdown.MAIN.started ] && (( $(bc <<<"${INPUTACV} < ${min_acvolt}") )); then echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - Shutting down main servers..." >> ${PW_LOGFILE} echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - Shutting down main servers..." >> ${PW_LOGPOWER} SENDNOTICE "BATT-VOLT LOW: SHUTDOWN MAIN SERVERS" "Battery Voltage LOW: ${BATTVOLT}'volts Shutting down main servers" 1 SHUTDOWN_MAIN POWER & fi elif [ ! -f ${PW_TMPFOLDER}/shutdown.MAIN.started ] && [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/power.dc.low)) -ge $(echo "scale=0; ${PW_SHUTDOWN_MAINSERVERS_AFTER}*60" | bc) ]; then echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - Shutting down main servers..." >> ${PW_LOGFILE} echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - Shutting down main servers..." >> ${PW_LOGPOWER} SENDNOTICE "BATT-VOLT LOW: SHUTDOWN MAIN SERVERS" "Battery Voltage LOW: ${BATTVOLT}'volts Shutting down main servers" 1 SHUTDOWN_MAIN POWER & fi volt_diff=`echo "scale=1; ${last_battvolt}-${BATTVOLT}" | bc` (( $(bc <<<"${volt_diff} < 0") )) && volt_diff=`echo "scale=1; ${volt_diff} * -1" | bc` if (( $(bc <<<"${volt_diff} > 0.5") )); then SENDNOTICE "BATTERY VOLTAGE CHANGE" "Battery Voltage: ${BATTVOLT}'volts" echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - Battery Voltage Change" >> ${PW_LOGPOWER} last_battvolt=${BATTVOLT} fi fi else sleep 20s fi ######offsite check # if [ "$(CHECK_HOST 10.2.1.1)" != "false" ]; then # upsinfo=$(ssh admin@10.2.1.1 'upsc CP1500PFCLCD') # OFFSITE_VOLTIN=$(echo "${upsinfo}" | grep 'input.voltage:' | sed 's/.*: //') # OFFSITE_BATT_RUNTIME=$(echo "${upsinfo}" | grep 'battery.runtime:' | sed 's/.*: //') # OFFSITE_BATT_RUNTIME=`echo "scale=2; ${OFFSITE_BATT_RUNTIME}/60" | bc` # OFFSITE_BATT_CAP=$(echo "${upsinfo}" | grep 'battery.charge:' | sed 's/.*: //') # # if (( $(bc <<<"${OFFSITE_VOLTIN} >= ${min_acvolt}") )); then # if [ -f ${PW_TMPFOLDER}/power.offsite.ac.low ]; then # echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${OFFSITE_VOLTIN}'volts - Offsite Back to Normal Voltage" >> ${PW_LOGPOWER} # echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${OFFSITE_VOLTIN}'volts - OFFSITE POWER NOMINAL AGAIN" >> ${PW_LOGFILE} # SENDNOTICE "OFFSITE POWER NOMINAL AGAIN" "Normal voltage detected # VOLTAGE: ${OFFSITE_VOLTIN}'volts" # rm -f ${PW_TMPFOLDER}/power.offsite.ac.* # fi # if [ -f ${PW_TMPFOLDER}/shutdown.OFFSITE ]; then # if [ ! -f ${PW_TMPFOLDER}/power.offsite.restored ]; then # touch ${PW_TMPFOLDER}/power.offsite.restored # # elif [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/power.offsite.restored)) -ge 60 ]; then # SENDNOTICE "OFFSITE HOST POWER" "Powering offsite host(s) back on after power was restored" # for offsite_host in "${PW_OFFSITEHOSTS[@]}"; do # HOSTPOWER ${offsite_host} on >/dev/null 2>&1 # done # rm -f ${PW_TMPFOLDER}/power.offsite.* # fi # # else # [ $(expr `date +%s` - $(stat -c %Y ${PW_LOGPOWER})) -le 300 ] && echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${OFFSITE_VOLTIN}'volts - Offsite Normal Voltage" >> ${PW_LOGPOWER} # fi # else # echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${OFFSITE_VOLTIN}'volts - OFFSITE POWER OFF/LOW POWER" >> ${PW_LOGPOWER} # echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${OFFSITE_VOLTIN}'volts - OFFSITE POWER OFF/LOW POWER" >> ${PW_LOGFILE} # # if [ ! -f ${PW_TMPFOLDER}/power.offsite.ac.low ] || [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/power.offsite.ac.low)) -ge 240 ]; then # SENDNOTICE "OFFSITE POWER ALERT - POWER OFF/LOW!!" "Power off or low voltage detected # BATT CAPACITY: ${OFFSITE_BATT_CAP}'%25 # BATT RUNTIME: ${OFFSITE_BATT_RUNTIME}'Mins" 1 # touch ${PW_TMPFOLDER}/power.offsite.ac.low # fi # # if (( $(bc <<<"${OFFSITE_BATT_CAP} <= 95") )) && [ ! -f ${PW_TMPFOLDER}/shutdown.OFFSITE ]; then # SENDNOTICE "OFFSITE HOST POWER" "Powering DOWN offsite host(s) due to power outage" 1 # SHUTDOWN_OFFSITE & # touch ${PW_TMPFOLDER}/shutdown.OFFSITE # fi # fi # # # fi sleep 10s done # & } POWERLOGGER_SERVICE(){ while true; do LogDataTime=`date +'%Y-%m-%d %H:%M:%S'` INVSTATSINFO=$(curl -s "http://${PW_INVERTER_IP}/stats.json") if [ "${INVSTATSINFO}" != "" ]; then INPUTV=`echo ${INVSTATSINFO} | jq '.inputs .inV'` INPUTA=`echo ${INVSTATSINFO} | jq '.inputs .inA'` OUTPUTV=`echo ${INVSTATSINFO} | jq '.outputs .outV'` OUTPUTA=`echo ${INVSTATSINFO} | jq '.outputs .outA'` OUTPUTW=`echo ${INVSTATSINFO} | jq '.outputs .outW'` BATTV=`echo ${INVSTATSINFO} | jq '.inputs .battV'` BATTA=`echo ${INVSTATSINFO} | jq '.inputs .xfA'` QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`volt\`, \`amp\`) VALUES ('${PW_POWERSENSOR_ID['inv-in']}','${LogDataTime}','${INPUTV}','${INPUTA}')" ${mysql_conn} -e "USE servermonitor; ${QRY}" QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`volt\`, \`amp\`, \`watt\`) VALUES ('${PW_POWERSENSOR_ID['inv-out']}','${LogDataTime}','${OUTPUTV}','${OUTPUTA}','${OUTPUTW}')" ${mysql_conn} -e "USE servermonitor; ${QRY}" QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`volt\`, \`amp\`) VALUES ('${PW_POWERSENSOR_ID['battery']}','${LogDataTime}','${BATTV}','${BATTA}')" ${mysql_conn} -e "USE servermonitor; ${QRY}" QRY="INSERT INTO inv_jsonstats (\`date\`, \`data\`) VALUES ('${LogDataTime}','${INVSTATSINFO}')" ${mysql_conn} -e "USE servermonitor; ${QRY}" fi if [ "$(CHECK_HOST ${PW_UPS_IP})" != "false" ]; then SVRRM_VOLT=$(snmpwalk -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.3.2.1.2.1.1 | sed 's/.*: //') SVRRM_VOLT=`echo "scale=1; ${SVRRM_VOLT}/10" | bc` SVRRM_WATT=$(snmpwalk -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.3.2.1.4.1.1 | sed 's/.*: //') SVRRM_AMP=$(snmpwalk -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.3.2.1.3.1.1 | sed 's/.*: //') SVRRM_AMP=`echo "scale=2; ${SVRRM_AMP}/100" | bc` QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`volt\`, \`amp\`, \`watt\`) VALUES ('${PW_POWERSENSOR_ID['total']}','${LogDataTime}','${SVRRM_VOLT}','${SVRRM_AMP}','${SVRRM_WATT}')" ${mysql_conn} -e "USE servermonitor; ${QRY}" fi if [ "$(CHECK_HOST ${PW_APCPDU_IP})" != "false" ]; then APCPDU_AMP=$(snmpwalk -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.2.3.1.1.2.1 | sed 's/.*: //') APCPDU_AMP=`echo "scale=1; ${APCPDU_AMP}/10" | bc` if [ "${SVRRM_VOLT}" != "" ]; then APCPDU_WATT=`echo "scale=2; ${APCPDU_AMP}*${SVRRM_VOLT}" | bc` QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`volt\`, \`amp\`, \`watt\`) VALUES ('${PW_POWERSENSOR_ID['server-rack']}','${LogDataTime}','${SVRRM_VOLT}','${APCPDU_AMP}','${APCPDU_WATT}')" else QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`amp\`) VALUES ('12','${LogDataTime}','${APCPDU_AMP}')" fi ${mysql_conn} -e "USE servermonitor; ${QRY}" fi if [ "${SVRRM_VOLT}" != "" ] && [ "${APCPDU_AMP}" != "" ]; then NETRK_AMP=`echo "scale=2; ${SVRRM_AMP}-${APCPDU_AMP}" | bc` NETRK_WATT=`echo "scale=0; ${SVRRM_WATT}-${APCPDU_WATT}" | bc` QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`volt\`, \`amp\`, \`watt\`) VALUES ('${PW_POWERSENSOR_ID['network-rack']}','${LogDataTime}','${SVRRM_VOLT}','${NETRK_AMP}','${NETRK_WATT}')" ${mysql_conn} -e "USE servermonitor; ${QRY}" fi upsinfo=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 admin@10.2.1.1 'upsc CP1500PFCLCD') if [ "$(echo "${upsinfo}" | grep 'input.voltage:')" != "" ]; then OFFSITE_VOLTOUT=$(echo "${upsinfo}" | grep 'output.voltage:' | sed 's/.*: //') OFFSITE_LOAD=$(echo "${upsinfo}" | grep 'ups.load:' | sed 's/.*: //') OFFSITE_LOAD=`echo "scale=2; ${OFFSITE_LOAD}/100" | bc` OFFSITE_WATTS=`echo "scale=2; ${OFFSITE_LOAD}*$(echo "${upsinfo}" | grep 'ups.realpower.nominal:' | sed 's/.*: //')" | bc` OFFSITE_AMPS=`echo "scale=2; ${OFFSITE_WATTS}/${OFFSITE_VOLTOUT}" | bc` QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`volt\`, \`amp\`, \`watt\`) VALUES ('${PW_POWERSENSOR_ID['offsite-ups']}','${LogDataTime}','${OFFSITE_VOLTOUT}','${OFFSITE_AMPS}','${OFFSITE_WATTS}')" ${mysql_conn} -e "USE servermonitor; ${QRY}" fi for SENSOR in ${PW_SENSOR_ORD[@]}; do if [ "${PW_HOST_IDRACS[${SENSOR}]}" != "" ]; then HOST_WATT_SENSORS=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.8.1 -O vq | sed -e 's/"//g') if [ "${HOST_WATT_SENSORS}" != "" ]; then IFS=$'\n' read -rd '' -a HOST_WATT_SENSORS <<<"${HOST_WATT_SENSORS}" unset IFS for s in {1..5}; do if [[ "$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.8.1.${s} | sed 's/.*: //')" = *"System Board"* ]]; then HOST_WATTS=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.6.1.${s} | sed 's/.*: //') if [[ "${HOST_WATTS}" != *"Timeout"* ]] && [ "${HOST_WATTS}" != "0" ]; then QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`watt\`) VALUES ('${PW_POWERSENSOR_ID[${SENSOR}]}','${LogDataTime}','${HOST_WATTS}')" ${mysql_conn} -e "USE servermonitor; ${QRY}" fi break fi done fi fi done if [ "$(compgen -G "${PW_TMPFOLDER}/temp.*")" != "" ] || [ "$(compgen -G "${PW_TMPFOLDER}/power.*")" != "" ]; then sleep ${PW_MYSQL_LOG_INTERVAL_ABNORMAL}m else sleep ${PW_MYSQL_LOG_INTERVAL_NORMAL}m fi done } HOSTPOWER(){ if [ "${PW_iDRACHOST_SHORTNAMES[${1}]}" != "" ]; then idracip=${1} elif [ "${PW_ESXI_HOST_NAMES[${1}]}" != "" ]; then tmp=${PW_ESXI_HOST_NAMES[${1}]} idracip=${PW_HOST_IDRACS[${tmp}]} elif [ "${PW_HOST_IDRACS[iDS-vMS-Host${1}]}" != "" ]; then idracip=${PW_HOST_IDRACS[iDS-vMS-Host${1}]} elif ([ "${1::1}" == "o" ] || [ "${1::1}" == "O" ]) && [ "${PW_HOST_ADDRESSES[OFF-vMS-Host${1: -1}]}" != "" ]; then idracip=${PW_HOST_IDRACS[OFF-vMS-Host${1}]} elif [ "${PW_HOST_IDRACS[${1}]}" != "" ]; then idracip=${PW_HOST_IDRACS[${1}]} else idracip='' fi # if [ "${PW_iDRACHOST_SHORTNAMES[${1}]}" != "" ]; then # tmp=${PW_iDRACHOST_SHORTNAMES[${1}]} # ESXI_HOST=${PW_HOST_ADDRESSES[${tmp}]} # elif [ "${PW_ESXI_HOST_NAMES[${1}]}" != "" ]; then # ESXI_HOST=${1} # elif [ "${PW_HOST_ADDRESSES[iDS-vMS-Host${1}]}" != "" ]; then # ESXI_HOST=${PW_HOST_ADDRESSES[iDS-vMS-Host${1}]} # elif ([ "${1::1}" == "o" ] || [ "${1::1}" == "O" ]) && [ "${PW_HOST_ADDRESSES[OFF-vMS-Host${1: -1}]}" != "" ]; then # ESXI_HOST=${PW_HOST_ADDRESSES[OFF-vMS-Host${1: -1}]} # elif [ "${PW_HOST_ADDRESSES[${1}]}" != "" ]; then # ESXI_HOST=${PW_HOST_ADDRESSES[${1}]} # elif [ "${1^^}" == "ALL" ] || [ "${1^^}" == "MAINSITE" ] || [ "${1^^}" == "OFFSITE" ] || [ "${1^^}" == "MAIN" ] || [ "${1^^}" == "SYS" ]; then # ESXI_HOST=${HOST^^} # MN=1 # else # ESXI_HOST='' # fi # [ "${ESXI_HOST}" != "" ] && idracip=${PW_HOST_IDRACS[${PW_ESXI_HOST_NAMES[${ESXI_HOST}]}]} || idracip='' echo -e "\n${idsCL[Yellow]}POWERING ${2^^} '${PW_iDRACHOST_SHORTNAMES[${idracip}]}'" DIVIDER . yellow 75 if [ "${idracip}" != "" ]; then # host=${PW_iDRACHOST_SHORTNAMES[${idracip}]} # c=0; spcA=''; spc1=`expr 21 - ${#host} - 1`; until [ ${c} = ${spc1} ]; do spcA="${spcA} "; c=`expr ${c} + 1`; done # c=0; spcB=''; spc1=`expr 18 - ${#PW_HOST_ADDRESSES[${host}]} - 1`; until [ ${c} = ${spc1} ]; do spcB="${spcB} "; c=`expr ${c} + 1`; done # echo -en "${idsCL[LightCyan]} Host: ${idsCL[Green]}${host}${spcA}" # echo -en "${idsCL[LightCyan]}Host IP: ${idsCL[Green]}${PW_HOST_ADDRESSES[${host}]}${spcB}" # echo -e "${idsCL[LightCyan]}iDrac IP: ${idsCL[Green]}${idracip}${idsCL[Default]}" # DIVIDER . yellow 75 # echo if [ "${2^^}" == "ON" ] || [ "${2^^}" == "OFF" ] || [ "${2^^}" == "STATUS" ]; then if [ "${idracip}" == "10.10.2.20" ] && [ "${2^^}" == "ON" ]; then MSG="Powering ON the SAS Enclosure" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "\n${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.14 i 1 >/dev/null 2>&1) sleep 3s echo -e "${idsCL[Green]}Done${idsCL[Default]}\n" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi fi if [ "${TEST}" != "true" ]; then echo -e "${idsCL[Green]}" ipmitool -I lanplus -H ${idracip} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" chassis power ${2,,} else echo -e "\n${idsCL[Yellow]}(TEST MODE)" fi echo -e "${idsCL[Default]}" if [ "${idracip}" == "10.10.2.20" ] && [ "${2^^}" == "OFF" ]; then MSG="Powering OFF the SAS Enclosure" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then if [ "$(CHECK_HOST 10.10.2.10)" == "false" ]; then run=$(snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.14 i 2 >/dev/null 2>&1) sleep 3s echo -e "${idsCL[Green]}Done${idsCL[Default]}\n" else echo -e "${idsCL[LightRed]}'${PW_iDRACHOST_SHORTNAMES[${idracip}]}' is not offline, not powering down\n" fi else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi fi else echo -e "${idsCL[LightRed]}'${2^^}' command is not recognized${idsCL[Default]}" fi else echo -e "${idsCL[LightRed]}Host cannot be found for '${1}'${idsCL[Default]}" fi echo -e "${idsCL[Default]}\n" } PDUCONTROL(){ function exitspacing { echo -e "\n\033[K\n\033[K" exit 0 } trap exitspacing EXIT while [ $# -gt 0 ]; do case "$1" in -port) PORT_SEL=${2};; esac shift 1 done echo DIVIDER . yellow 75 echo -e "${idsCL[Yellow]}APC-PDU Power Control" DIVIDER true yellow 75 [ "${PORT_SEL}" != "" ] && PORTSEL=${PORT_SEL} if [ "${PORTSEL}" == "" ]; then PORT_DESC=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.2 -O vq 2> /dev/null | sed -e 's/"//g') IFS=$'\n' read -rd '' -a PORT_DESC <<<"${PORT_DESC}" unset IFS p=1 for port in "${PORT_DESC[@]}"; do portpower=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.${p} -O vq 2> /dev/null | sed -e 's/"//g') [ ${portpower} -eq 1 ] && portpower_disp="${idsCL[Green]}ON" || portpower_disp="${idsCL[LightRed]}OFF" [ ${p} -lt 10 ] && pp=" ${p}" || pp=${p} c=0; spc=''; spc1=`expr 28 - ${#port}`; until [ ${c} = ${spc1} ]; do spc="${spc} "; c=`expr ${c} + 1`; done echo -e "${pp}) ${idsCL[LightCyan]}${port}${spc}${idsCL[Default]}: ${portpower_disp}${idsCL[Default]}" ((p++)) done echo -e "" echo -e "" echo -e "(${idsCL[Yellow]}E${idsCL[Default]})xit" echo -e "" echo -e "\033[5A" until [ "${PORTSEL}" != "" ]; do echo -en "\n${idsCL[LightCyan]}Enter the port number to control: ${idsCL[Default]}" read PORTSEL echo done fi [ "${PORTSEL^^}" == "E" ] && exit 0 portsel_power=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.${PORTSEL} -O vq 2> /dev/null | sed -e 's/"//g') [ ${portsel_power} -eq 1 ] && portsel_power_disp="${idsCL[Green]}ON" || portsel_power_disp="${idsCL[LightRed]}OFF" [ ${portsel_power} -eq 2 ] && portsel_change_power_disp="${idsCL[Green]}ON" || portsel_change_power_disp="${idsCL[LightRed]}OFF" if [ "${PORT_SEL}" != "" ]; then portdesc=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.2.${PORT_SEL} -O vq 2> /dev/null | sed -e 's/"//g') echo -e "${idsCL[Yellow]}Port ${PORT_SEL}${idsCL[Default]}) ${idsCL[LightCyan]}${portdesc} ${idsCL[Default]}: ${portsel_power_disp}${idsCL[Default]}\n" fi echo -en "${idsCL[LightCyan]}Are you sure you wish to turn ${portsel_change_power_disp}${idsCL[LightCyan]} port ${idsCL[Yellow]}${PORTSEL}${idsCL[Default]} (y/N): " read -n 1 portchange_confirm case "${portchange_confirm}" in [Yy]) [ ${portsel_power} -eq 1 ] && portsel_change=2 || portsel_change=1 echo -en "\n\n${idsCL[LightCyan]}Turning ${portsel_change_power_disp}${idsCL[LightCyan]} port ${idsCL[Yellow]}${PORTSEL}${idsCL[Default]} ... " run=$(snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.${PORTSEL} i ${portsel_change} >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" echo if [ "${PORT_SEL}" == "" ]; then sleep 1s unset PORTSEL PDUCONTROL exit 0 fi ;; *) if [ "${PORT_SEL}" == "" ]; then unset PORTSEL PDUCONTROL exit 0 fi ;; esac }