#!/usr/bin/env bash # powerwall - CLI commands to control VM guest power PW_ACTION="${1}" source /opt/idssys/defaults/colors.inc source /opt/idssys/defaults/default.inc source /opt/idssys/powerwall/defaults.inc source ${PW_FOLDER}/shutdown-test.sh TEST=true shopt -s lastpipe VERBOSE=false CHECKTEMP(){ start=`date +%s` cw=25; while [ $# -gt 0 ]; do case "$1" in -a|-avg) avgdays=${2};; -S|-sensors) temptype="sensors";; -e|-esxi) temptype="esxi";; -s|-search) search=${2};; esac shift 1 done echo if [ "${avgdays}" != "" ]; then [ ${avgdays} -lt 10 ] && avgdays_disp=" ${avgdays}" || avgdays_disp=${avgdays} echo -e "${idsCL[Cyan]}Sensor Temperature(s) Current / ${idsCL[LightYellow]}${avgdays_disp}DayAVG ${idsCL[Yellow]}warning${idsCL[Default]} / ${idsCL[LightRed]}critical${idsCL[Default]}" else avgdays=noavg echo -e "${idsCL[Cyan]}Sensor Temperature(s) Current ${idsCL[Yellow]}warning${idsCL[Default]} / ${idsCL[LightRed]}critical${idsCL[Default]}" fi DIVIDER . yellow 90 for SENSOR in ${PW_SENSOR_ORD[@]}; do if [ "${search}" == "" ] || [[ "${SENSOR,,}" = *"${search,,}"* ]]; then if [ "${PW_SENSOR_TYPE[${SENSOR}]}" == "esxi" ] && [ "${temptype}" != "sensors" ]; then vHOSTiDRACIP=${PW_HOST_IDRACS[${SENSOR}]} vHOSTIP=${PW_HOST_ADDRESSES[${SENSOR}]} vHOSTNAME=${PW_ESXI_HOST_NAMES[${vHOSTiDRACIP}]} echo -e "\r\033[K${idsCL[White]}${idsST[Bold]}${SENSOR} Host Sensors ${idsST[Reset]}${idsCL[White]}[${vHOSTiDRACIP}]${idsCL[Default]}" echo -en "${idsCL[Yellow]}Pulling data for '${SENSOR}' ... " if [ "$(CHECK_HOST ${vHOSTIP})" != "false" ]; then vHOST_TEMPNAMES=$(snmpwalk -v 1 -c public -t 2 ${vHOSTiDRACIP} .1.3.6.1.4.1.674.10892.5.4.700.20.1.8 -O vq | sed -e 's/"//g' | sed -e 's/ Temp//g') IFS=$'\n' read -rd '' -a vHOST_TEMPNAMES <<<"${vHOST_TEMPNAMES}" unset IFS echo -en "\r\033[K" if [ ${#vHOST_TEMPNAMES[@]} > 1 ]; then t=1 for sensorname in "${vHOST_TEMPNAMES[@]}"; do temp_c=$(snmpwalk -v 1 -c public -t 2 ${vHOSTiDRACIP} .1.3.6.1.4.1.674.10892.5.4.700.20.1.6.1.${t} -O vq | sed -e 's/"//g') temp_c=`echo "scale=1; ${temp_c}/10" | bc` temp_warn=$(snmpwalk -v 1 -c public -t 2 ${vHOSTiDRACIP} .1.3.6.1.4.1.674.10892.5.4.700.20.1.11.1.${t} -O vq | sed -e 's/"//g') temp_warn=`echo "scale=1; ${temp_warn}/10" | bc` temp_crit=$(snmpwalk -v 1 -c public -t 2 ${vHOSTiDRACIP} .1.3.6.1.4.1.674.10892.5.4.700.20.1.10.1.${t} -O vq | sed -e 's/"//g') temp_crit=`echo "scale=1; ${temp_crit}/10" | bc` c=0; spc=''; spc1=`expr ${cw} - ${#sensorname} - 1`; until [ ${c} = ${spc1} ]; do spc="${spc} "; c=`expr ${c} + 1`; done [ "${avgdays}" != "noavg" ] && echo -en "${idsCL[LightCyan]} ${sensorname}${spc}${idsCL[Default]}: ${idsCL[Yellow]}Calculating ${avgdays} Day average ... " reading=$(CHECKTEMPSENSOR ${SENSOR} ${temp_c} ${temp_warn} ${temp_crit} ${sensorname// /_} ${avgdays}) [ "${avgdays}" != "noavg" ] && echo -en "\r\033[K" echo -e "${idsCL[LightCyan]} ${sensorname}${spc}${idsCL[Default]}: ${reading}" ((t++)) done else echo -e "${idsCL[LightCyan]} ${vHOSTNAME}${spc}${idsCL[Default]}: No Data" fi else #host down echo -e "\r\033[K${idsCL[LightRed]}${SENSOR} Host is down" # if [ ! -f ${PW_TMPFOLDER}/${SENSOR}.down ] || [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/${SENSOR}.down)) -ge 1800 ]; then # SENDNOTICE "${vHOSTiDRACIP} ERROR" "${vHOSTNAME} Host is down" 1 # echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${vHOSTiDRACIP} - ${vHOSTNAME} Host is down" >> ${logtemp} # touch ${PW_TMPFOLDER}/${EHOST}.down # fi fi echo elif [ "${PW_SENSOR_TYPE[${SENSOR}]}" != "esxi" ] && [ "${temptype}" != "esxi" ]; then [[ "${SENSOR}" == *"CPU-Usage"* ]] && echo -en "\033[1A" c=0; spc=''; spc1=`expr ${cw} - ${#SENSOR}`; until [ ${c} = ${spc1} ]; do spc="${spc} "; c=`expr ${c} + 1`; done echo -en "\r\033[K${idsCL[White]}${idsST[Bold]}${SENSOR}${idsST[Reset]}${spc}${idsCL[Default]}: ${idsCL[Yellow]}" [ "${avgdays}" != "noavg" ] && echo -en "Pulling data and calculating ${avgdays} Day average ... " || echo -en "Pulling data ... " reading=$(CHECKTEMPSENSOR ${SENSOR} . . . . ${avgdays}) echo -e "\r\033[K${idsCL[White]}${idsST[Bold]}${SENSOR}${idsST[Reset]}${spc}${idsCL[Default]}: ${reading}" echo fi fi done end=`date +%s`; runtime=$((end-start)); echo -e "\nruntime: ${runtime}" [ "${PW_ACTION}" != "" ] && echo } CHECKTEMPSENSOR(){ echo ${PW_THRESHOLDS[${1}]} | cut -d',' -f 1 | read temp_warn echo ${PW_THRESHOLDS[${1}]} | cut -d',' -f 2 | read temp_crit [ "${PW_SENSOR_TYPE[${1}]}" == "cpu" ] && GAUGESH="'%" || GAUGESH="'F" if [ "${6}" != "noavg" ]; then [ "${6}" != "" ] && [[ "${6}" =~ ^[0-9]+$ ]] && avgdays=${6} || avgdays=3 if [ "${PW_SENSOR_TYPE[${1}]}" != "esxi" ]; then average=$(AVERAGETEMP ${PW_SENSOR_ID[${1}]} ${avgdays}) else average=$(AVERAGETEMP ${PW_SENSOR_ID[${1}]} ${avgdays} ${5}) fi else average='' fi if [ "${PW_SENSOR_TYPE[${1}]}" == "mqtt" ]; then mqtt_message=`${mqtt_conn} -t tele/${1}/SENSOR -C 1` echo ${mqtt_message} | cut -d':' -f 6 | cut -d',' -f 1 | read temp_c elif [ "${PW_SENSOR_TYPE[${1}]}" == "system" ]; then temp_c=$(vcgencmd measure_temp) temp_c=${temp_c%\'*}; temp_c=${temp_c#*=} elif [ "${PW_SENSOR_TYPE[${1}]}" == "remotesystem" ]; then temp_c=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 root@${PW_REMOTE_SENSORS[${1}]} vcgencmd measure_temp) if [ "${temp_c}" != "" ]; then temp_c=${temp_c%\'*}; temp_c=${temp_c#*=} fi elif [ "${PW_SENSOR_TYPE[${1}]}" == "esxi" ]; then temp_c=${2} temp_warn=`echo $(bc <<< "scale=2; (${3}*1.8+32)/1") | awk '{print int($1+0.5)}'` temp_crit=`echo $(bc <<< "scale=2; (${4}*1.8+32)/1") | awk '{print int($1+0.5)}'` elif [ "${PW_SENSOR_TYPE[${1}]}" == "cpu" ]; then if [ "${1}" == "Powerwall-CPU-Usage" ]; then temp_c=$(awk '{u=$2+$4; t=$2+$4+$5; if (NR==1){u1=u; t1=t;} else print ($2+$4-u1) * 100 / (t-t1) "%"; }' <(grep 'cpu ' /proc/stat) <(sleep 1;grep 'cpu ' /proc/stat) | sed -e 's/%//g') else temp_c=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 root@${PW_REMOTE_SENSORS[${1}]} "/opt/idssys/defaults/get-data.sh cpu-usage") fi fi if [ "${temp_c}" != "null" ] && [ "${temp_c}" != "" ]; then [ "${PW_SENSOR_TYPE[${1}]}" == "cpu" ] && temp_f=$(echo "scale=2; $temp_c/1" | bc -l) || temp_f=$(bc <<< "scale=1; ${temp_c}*1.8+32") (( $(bc <<<"${temp_f} < 1") )) && [[ "${temp_f}" = *"."* ]] && temp_f="0${temp_f}" [ "${1}" == "ServerRoomTH" ] && temp_f=`echo "scale=1; ${temp_f}+${PW_ServerRoomTH_Dev}" | bc` # echo "HERE: '${temp_c}' -> '${temp_f}'" # echo -en "" c=0; spct=''; spc1=`expr 6 - ${#temp_f}`; until [ ${c} = ${spc1} ]; do spct="${spct} "; c=`expr ${c} + 1`; done if [ "${average}" != "" ]; then c=0; spca=''; spc1=`expr 6 - ${#average}`; until [ ${c} = ${spc1} ]; do spca="${spca} "; c=`expr ${c} + 1`; done if [ "${average}" == "" ]; then averagedisp="${idsCL[Green]}" elif [ $(bc -l <<< "${average} >= ${temp_warn}") -eq 1 ] && [ $(bc -l <<< "${average} < ${temp_crit}") -eq 1 ]; then averagedisp="${idsCL[Yellow]}${average}" elif [ $(bc -l <<< "${average} >= ${temp_crit}") -eq 1 ]; then averagedisp="${idsCL[LightRed]}${average}" else averagedisp="${idsCL[Green]}${average}" fi fi if [ $(bc -l <<< "${temp_f} >= ${temp_warn}") -eq 1 ] && [ $(bc -l <<< "${temp_f} < ${temp_crit}") -eq 1 ]; then [ "${average}" != "" ] && echo -en "${idsCL[Yellow]}WARNING ${spct}${temp_f}${GAUGESH} /${spca}${averagedisp}${GAUGESH}${idsCL[Default]}" || echo -en "${idsCL[Yellow]}WARNING ${spct}${temp_f}${GAUGESH}${idsCL[Default]}" elif [ $(bc -l <<< "${temp_f} >= ${temp_crit}") -eq 1 ]; then [ "${average}" != "" ] && echo -en "${idsCL[LightRed]}CRITICAL${spct}${temp_f}${GAUGESH} /${spca}${averagedisp}${GAUGESH}${idsCL[Default]}" || echo -en "${idsCL[LightRed]}CRITICAL${spct}${temp_f}${GAUGESH}${idsCL[Default]}" else [ "${average}" != "" ] && echo -en "${idsCL[Green]}Normal ${spct}${temp_f}${GAUGESH} /${spca}${averagedisp}${GAUGESH}${idsCL[Default]}" || echo -en "${idsCL[Green]}Normal ${spct}${temp_f}${GAUGESH}${idsCL[Default]}" fi tmp="${spct}${temp_f}" c=0; spc=''; spc1=`expr 10 - ${#tmp}`; until [ ${c} = ${spc1} ]; do spc="${spc} "; c=`expr ${c} + 1`; done [ ${#temp_warn} == 2 ] && spcw=' ' || spcw=' ' [ ${#temp_crit} == 2 ] && spcc=' ' || spcc=' ' echo -e "${spc}[${spcw}${idsCL[Yellow]}${temp_warn}${GAUGESH}${idsCL[Default]} /${spcc}${idsCL[LightRed]}${temp_crit}${GAUGESH}=>${idsCL[Default]} ]" fi } AVERAGETEMP(){ temptotal=0 daysback=${2} sensorid=${1} logsfound=0; if [ "${3}" != "" ]; then entityid=($(${mysql_conn} -e "SELECT id FROM servermonitor.entities WHERE BINARY name='${3}' AND sensorid='${sensorid}'")) entityid=${entityid[1]} WHERE="sensorid=${sensorid} AND entity=${entityid}" else WHERE="sensorid=${sensorid}" fi while IFS=$'\t' read date temp hum ;do temptotal=$(bc <<< "scale=1; ${temptotal}+${temp}") ((logsfound++)) done < <(${mysql_conn} -se "USE servermonitor; SELECT date,temp,hum from sensor_data WHERE ${WHERE} AND date BETWEEN DATE_SUB(DATE(NOW()), INTERVAL ${daysback} DAY) AND NOW() ORDER BY id DESC;") average=$(bc <<< "scale=1; ${temptotal}/${logsfound}") (( $(bc <<<"${average} < 1") )) && [[ "${average}" = *"."* ]] && average="0${average}" echo ${average} # echo ${logsfound} } SENDDAILY(){ dailtemp=$(DAILYTEMP) SENDNOTICE "Daily Temp Readings" "${dailtemp}" } CHECKTEMP_SERVICE(){ cw=20 declare -A last_temp echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - 'Check Temp' Service Startup" >> ${PW_LOGFILE} while true; do # start=`date +%s` # time="$(date +%H)$(date +%M)" # if [ ! -f ${PW_TMPFOLDER}/temp.* ] && [ $(date +%H)$(date +%M) -ge 0700 ] && [ $(date +%H)$(date +%M) -lt 0705 ]; then # if [ ! -f ${PW_TMPFOLDER}/.sentdaily ] || [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/.sentdaily)) -gt 600 ]; then # touch ${PW_TMPFOLDER}/.sentdaily # SENDDAILY & # fi # fi for SENSORa in ${PW_SENSOR_ORD[@]}; do logtemp=${PW_LOGFOLDER}/log-temp-${SENSORa} [ ! -f ${logtemp} ] && touch ${logtemp} [ $(expr `date +%s` - $(stat -c %Y ${logtemp})) -ge $(echo "scale=0; ${PW_LOG_INTERVAL_NORMAL}*60" | bc) ] && relog=1 || relog=0 if ([ "${PW_REMOTE_SENSORS[${SENSORa}]}" != "" ] && [ "$(CHECK_HOST ${PW_REMOTE_SENSORS[${SENSORa}]})" != "false" ]) || ([ "${PW_HOST_ADDRESSES[${SENSORa}]}" != "" ] && [ "$(CHECK_HOST ${PW_HOST_ADDRESSES[${SENSORa}]})" != "false" ]); then # if ([ "${PW_REMOTE_SENSORS[${SENSORa}]}" != "" ] && [ "$(CHECK_HOST ${PW_REMOTE_SENSORS[${SENSORa}]})" != "false" ]); then if [ -f ${PW_TMPFOLDER}/${SENSORa}.down ]; then SENDNOTICE "${SENSORa} Online" "${SENSORa} Sensor is back online" echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${SENSORa} - Sensor is back online" >> ${logtemp} rm -f ${PW_TMPFOLDER}/${SENSORa}.down fi if [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "esxi" ]; then vHOST_TEMPNAMES=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSORa}]} .1.3.6.1.4.1.674.10892.5.4.700.20.1.8 -O vq | sed -e 's/"//g' | sed -e 's/ Temp//g') IFS=$'\n' read -rd '' -a SENSORS_CHECK <<<"${vHOST_TEMPNAMES}" unset IFS [ -f ${PW_TMPFOLDER}/power.${SENSORa}.off ] && [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/power.${SENSORa}.off)) -ge 300 ] && rm-f ${PW_TMPFOLDER}/power.${SENSORa}.off t=1 else SENSORS_CHECK=(${SENSORa}) fi if [ "${SENSORS_CHECK}" != "" ]; then for SENSOR in "${SENSORS_CHECK[@]}"; do if [ "${PW_THRESHOLDS[${SENSORa}]}" != "" ]; then echo ${PW_THRESHOLDS[${SENSORa}]} | cut -d',' -f 1 | read temp_warn echo ${PW_THRESHOLDS[${SENSORa}]} | cut -d',' -f 2 | read temp_crit [ "$(echo ${PW_THRESHOLDS[${SENSORa}]} | cut -d',' -f 3)" != "" ] && echo ${PW_THRESHOLDS[${SENSORa}]} | cut -d',' -f 3 | read temp_crit_sys || temp_crit_sys=${temp_crit} fi if [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "mqtt" ]; then mqtt_message=`${mqtt_conn} -t tele/${SENSOR}/SENSOR -C 1` echo ${mqtt_message} | cut -d':' -f 7 | cut -d',' -f 1 | read temp_h echo ${mqtt_message} | cut -d':' -f 6 | cut -d',' -f 1 | read temp_c elif [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "system" ]; then temp_c=$(vcgencmd measure_temp) temp_c=${temp_c%\'*}; temp_c=${temp_c#*=} temp_h='' elif [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "remotesystem" ]; then temp_c=$(ssh root@${PW_REMOTE_SENSORS[${SENSOR}]} vcgencmd measure_temp) temp_c=${temp_c%\'*}; temp_c=${temp_c#*=} temp_h='' elif [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "esxi" ]; then temp_c=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSORa}]} .1.3.6.1.4.1.674.10892.5.4.700.20.1.6.1.${t} -O vq | sed -e 's/"//g') temp_c=`echo "scale=1; ${temp_c}/10" | bc` temp_warn=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSORa}]} .1.3.6.1.4.1.674.10892.5.4.700.20.1.11.1.${t} -O vq | sed -e 's/"//g') temp_warn=`echo "scale=1; ${temp_warn}/10" | bc` temp_warn=$(echo "scale=2; ${temp_warn}*1.8 + 32" | bc) temp_crit=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSORa}]} .1.3.6.1.4.1.674.10892.5.4.700.20.1.10.1.${t} -O vq | sed -e 's/"//g') temp_crit=`echo "scale=1; ${temp_crit}/10" | bc` temp_crit=$(echo "scale=2; ${temp_crit}*1.8 + 32" | bc) temp_crit_sys=${temp_crit} temp_h='' vSENSOR=${SENSOR} SENSOR="${SENSORa}-${vSENSOR// /_}" ((t++)) elif [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "cpu" ]; then if [ "${SENSORa}" == "Powerwall-CPU-Usage" ]; then temp_c=$(awk '{u=$2+$4; t=$2+$4+$5; if (NR==1){u1=u; t1=t;} else print ($2+$4-u1) * 100 / (t-t1) "%"; }' <(grep 'cpu ' /proc/stat) <(sleep 1;grep 'cpu ' /proc/stat) | sed -e 's/%//g') else temp_c=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 root@${PW_REMOTE_SENSORS[${SENSORa}]} "/opt/idssys/defaults/get-data.sh cpu-usage") fi temp_h='' fi [ "${last_temp[${SENSOR//-/}]}" == "" ] && last_temp[${SENSOR//-/}]=0 logtemp=${PW_LOGFOLDER}/log-temp-${SENSOR} if [ "${temp_c}" != "null" ] && [ "${temp_c}" != "" ]; then [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "cpu" ] && GAUGE="CPU-USAGE" || GAUGE="TEMP" [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "cpu" ] && GAUGESH='%' || GAUGESH="'F" if [ -f ${PW_TMPFOLDER}/${SENSOR}-error.reading ]; then SENDNOTICE "${SENSOR} Data" "${SENSOR} is reporting data again" echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${SENSOR} - Sensor is reporting data again" >> ${logtemp} rm -f ${PW_TMPFOLDER}/${SENSOR}-error.reading fi [ "${PW_SENSOR_TYPE[${SENSOR}]}" == "cpu" ] && temp_f=$(echo "scale=2; $temp_c/1" | bc -l) || temp_f=$(echo "scale=2; ${temp_c}*1.8 + 32" | bc) [ "${SENSOR}" == "ServerRoomTH" ] && temp_f=`echo "scale=2; ${temp_f}+${PW_ServerRoomTH_Dev}" | bc` # echo "HERE: [${SENSOR//-/}] - ${last_temp[${SENSOR//-/}]} - ${temp_c} - ${temp_f} - ${temp_warn} - ${temp_crit} - ${temp_crit_sys}" # [ ! "${temp_c}" ] || [ ! "${temp_f}" ] || [ ! "${temp_warn}" ] || [ ! "${temp_crit}" ] || [ ! "${temp_crit_sys}" ] && echo "VALUE NOT FOUND" if [ "${PW_SENSOR_TYPE[${SENSORa}]}" != "esxi" ]; then echo ${PW_THRESHOLDS[${SENSOR}]} | cut -d',' -f 1 | read temp_warn echo ${PW_THRESHOLDS[${SENSOR}]} | cut -d',' -f 2 | read temp_crit echo ${PW_THRESHOLDS[${SENSOR}]} | cut -d',' -f 3 | read temp_crit_sys fi if (( $(bc <<< "${temp_f} < ${temp_warn}") )); then if (( $(bc <<< "${last_temp[${SENSOR//-/}]} > 1") )); then SENDNOTICE "${SENSOR} BACK TO NORMAL" "NORMAL TEMP: ${temp_f}${GAUGESH} Previous Temp: ${last_temp[${SENSOR//-/}]}${GAUGESH}" echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${temp_f}${GAUGESH} - Back to NORMAL ${GAUGE} - Previous ${GAUGE}: ${last_temp[${SENSOR//-/}]}${GAUGESH}" >> ${logtemp} echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${temp_f}${GAUGESH} - ${SENSOR} - Back to NORMAL ${GAUGE}" >> ${PW_LOGFILE} # [ "$(compgen -G "${PW_TMPFOLDER}/power.*.off")" != "" ] && rm -f ${PW_TMPFOLDER}/power.*.off elif [ "${last_temp[${SENSOR//-/}]}" == "0" ]; then # SENDNOTICE "${SENSOR} TEMP NORMAL" "Service Startup # NORMAL TEMP: ${temp_f}${GAUGESH}" echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${temp_f}${GAUGESH} - Service Startup - NORMAL ${GAUGE}" >> ${logtemp} echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${temp_f}${GAUGESH} - ${SENSOR} - Service Startup" >> ${PW_LOGFILE} # [ "$(compgen -G "${PW_TMPFOLDER}/power.*.off")" != "" ] && rm -f ${PW_TMPFOLDER}/power.*.off elif [ "${relog}" == "1" ]; then echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${temp_f}${GAUGESH} - Normal ${GAUGE}" >> ${logtemp} fi rm -f ${PW_TMPFOLDER}/temp.* rm -f ${PW_TMPFOLDER}/power.${SENSORa}.off last_temp[${SENSOR//-/}]=1 # iDS-vMS-Offsite Fan Issue Workaround if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ]; then vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSORa}]} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.3 -O vq) # vHOSTFAN=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${SENSORa}]} -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1) if [ "${vHOSTFAN}" != "" ]; then FanSpeed=`echo "scale=2; ${vHOSTFAN}/21200" | bc`; FanSpeed=`echo "scale=0; ${FanSpeed}*100" | bc | sed -e 's/.00//g'` # FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g') if [ ${FanSpeed} -lt 26 ] || [ ${FanSpeed} -gt 34 ]; then # if [ ${FanSpeed} -ne 30 ]; then SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} Fan Issue" "Settings fans back to normal 30%25" ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00 >/dev/null 2>&1 ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0x1E >/dev/null 2>&1 fi fi fi else ([ ! "${last_temp[${SENSOR//-/}]}" ] || (( $(bc <<< "${last_temp[${SENSOR//-/}]} < 2") ))) && last_temp[${SENSOR//-/}]=${temp_f} temp_diff=`echo "scale=2; ${last_temp[${SENSOR//-/}]}-${temp_f}" | bc` [ $(bc -l <<< "${temp_diff} < 0") -eq 1 ] && temp_diff=`echo "scale=2; ${temp_diff}*-1" | bc` if [ $(bc -l <<< "${temp_f} >= ${temp_warn}") -eq 1 ] && [ $(bc -l <<< "${temp_f} < ${temp_crit}") -eq 1 ]; then touch ${PW_TMPFOLDER}/temp.warn if (( $(bc <<< "${temp_diff} > 1") )) || (( $(bc <<< "${temp_diff} = 1") )); then SENDNOTICE "${SENSOR} ${GAUGE} WARNING" "WARNING ${GAUGE}: ${temp_f}${GAUGESH} - (Difference of ${temp_diff}')" 1 last_temp[${SENSOR//-/}]=${temp_f} echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${temp_f}${GAUGESH} - WARNING ${GAUGE} - (Difference of ${temp_diff}')" >> ${logtemp} # iDS-vMS-Offsite Fan Issue Workaround if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ] && [ ${FanSpeed} -ne 80 ]; then SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} SERVER WARM" "Setting fan speeds to 80%25" 1 ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00 >/dev/null 2>&1 ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0x50 >/dev/null 2>&1 fi fi elif [ $(bc -l <<< "${temp_f} >= ${temp_crit}") -eq 1 ] && [ $(bc -l <<< "${temp_f} < ${temp_crit_sys}") -eq 1 ]; then if (( $(bc <<< "${temp_diff} > 1") )) || (( $(bc <<< "${temp_diff} = 1") )); then SENDNOTICE "${SENSOR} ${GAUGE} CRITICAL" "CRITICAL ${GAUGE}: ${temp_f}${GAUGESH} - (Difference of ${temp_diff}')" 1 echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${temp_f}${GAUGESH} - CRITICAL - (Difference of ${temp_diff}${GAUGESH})" >> ${logtemp} echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${SENSOR} - ${temp_f}${GAUGESH} - CRITICAL ${GAUGE} - (Difference of ${temp_diff}')" >> ${PW_LOGFILE} last_temp[${SENSOR//-/}]=${temp_f} if [ "${SENSOR}" == "ServerRoomTH" ] && [ ! -f touch ${PW_TMPFOLDER}/temp.crit ]; then touch ${PW_TMPFOLDER}/temp.crit SHUTDOWN_MAIN ${SENSOR} & echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${temp_f}${GAUGESH} - Shutting down MAIN servers" >> ${logtemp} # elif [ ! -f ${PW_TMPFOLDER}/power.${SENSORa}.off ]; then # SENDNOTICE "${SENSORa} TEMP CRITICAL" "Host system and VMs shutting down!!" 1 # SHUTDOWN_SERVER ${SENSORa} & # touch ${PW_TMPFOLDER}/power.${SENSORa}.off fi fi elif [ $(bc -l <<< "${temp_f} >= ${temp_crit_sys}") -eq 1 ]; then if (( $(bc <<< "${temp_diff} > 1") )) || (( $(bc <<< "${temp_diff} = 1") )); then SENDNOTICE "${SENSOR} TEMP CRITICAL" "SYSTEM CRITICAL ${GAUGE}: ${temp_f}${GAUGESH} - (Difference of ${temp_diff}')" 1 echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${temp_f}${GAUGESH} - SYSTEM CRITICAL - (Difference of ${temp_diff})" >> ${logtemp} echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${temp_f}${GAUGESH} - ${SENSOR} - CRITICAL ${GAUGE} SYSTEM - (Difference of ${temp_diff}')" >> ${PW_LOGFILE} last_temp[${SENSOR//-/}]=${temp_f} if [ ! -f touch ${PW_TMPFOLDER}/temp.critsys ]; then touch ${PW_TMPFOLDER}/temp.critsys [ "${SENSOR}" == "ServerRoomTH" ] && SHUTDOWN_SYS ${SENSOR} TEMP & SHUTDOWN_CRIT ${SENSOR} & echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${temp_f}${GAUGESH} - Sending system shutdown signals, if applicable. Check main Powerwall Logs" >> ${logtemp} fi fi fi fi [ -f ${PW_TMPFOLDER}/${SENSOR}.insert ] && lastinsert=$(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/${SENSOR}.insert)) || lastinsert=100000 if [ "$(compgen -G "${PW_TMPFOLDER}/temp.*")" != "" ] || [ "$(compgen -G "${PW_TMPFOLDER}/power.ac.*")" != "" ] || [ "$(compgen -G "${PW_TMPFOLDER}/power.dc.*")" != "" ]; then wait=$(echo "scale=0; ${PW_MYSQL_LOG_INTERVAL_ABNORMAL}*60" | bc) else wait=$(echo "scale=0; ${PW_MYSQL_LOG_INTERVAL_NORMAL}*60" | bc) fi if [ "${PW_SENSOR_ID[${SENSORa}]}" != "" ] && [ ${lastinsert} -ge ${wait} ]; then if [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "esxi" ]; then entityid=($(${mysql_conn} -e "SELECT id FROM servermonitor.entities WHERE BINARY name='${vSENSOR// /_}' AND sensorid='${PW_SENSOR_ID[${SENSORa}]}'")) if [ "${entityid[1]}" == "" ]; then ${mysql_conn} -e "USE servermonitor; INSERT INTO entities (\`sensorid\`, \`name\`) VALUES ('${PW_SENSOR_ID[${SENSORa}]}','${vSENSOR// /_}')" entityid=($(${mysql_conn} -e "SELECT id FROM servermonitor.entities WHERE BINARY name='${vSENSOR// /_}' AND sensorid='${PW_SENSOR_ID[${SENSORa}]}'")) fi entityid=${entityid[1]} QRY="USE servermonitor; INSERT INTO sensor_data (\`sensorid\`, \`entity\`, \`date\`, \`temp\`) VALUES ('${PW_SENSOR_ID[${SENSORa}]}','${entityid}','$(date +'%Y-%m-%d %H:%M:%S')','${temp_f}')" if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ] && [ "${vSENSOR// /_}" == "System_Board_Inlet" ] && [ "${vHOSTFAN}" != "" ]; then ${mysql_conn} -e "USE servermonitor; INSERT INTO sensor_data (\`sensorid\`, \`date\`, \`speed\`) VALUES ('14','$(date +'%Y-%m-%d %H:%M:%S')','${FanSpeed}')" fi elif [ "${temp_h}" != "" ]; then QRY="USE servermonitor; INSERT INTO sensor_data (\`sensorid\`, \`date\`, \`temp\`, \`hum\`) VALUES ('${PW_SENSOR_ID[${SENSORa}]}','$(date +'%Y-%m-%d %H:%M:%S')','${temp_f}','${temp_h}')" else QRY="USE servermonitor; INSERT INTO sensor_data (\`sensorid\`, \`date\`, \`temp\`) VALUES ('${PW_SENSOR_ID[${SENSORa}]}','$(date +'%Y-%m-%d %H:%M:%S')','${temp_f}')" fi ${mysql_conn} -e "${QRY}" touch ${PW_TMPFOLDER}/${SENSOR}.insert fi else if [ ! -f ${PW_TMPFOLDER}/${SENSOR}-error.reading ] || [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/${SENSOR}-error.reading)) -ge 1800 ]; then SENDNOTICE "${SENSOR} Sensor ERROR" "ERROR reading sensor data" 1 echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${SENSOR} Sensor - ERROR reading sensor data" >> ${logtemp} touch ${PW_TMPFOLDER}/${SENSOR}-error.reading fi fi done fi elif [ "${PW_HOST_ADDRESSES[${SENSORa}]}" == "" ]; then #sensor down if [ ! -f ${PW_TMPFOLDER}/${SENSORa}.down ] || [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/${SENSORa}.down)) -ge 1800 ]; then SENDNOTICE "${SENSORa} ERROR" "${SENSORa} Sensor is down" 1 echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${SENSORa} - ${SENSORa} Sensor is down" >> ${logtemp} touch ${PW_TMPFOLDER}/${SENSORa}.down fi fi done # end=`date +%s`; runtime=$((end-start)); echo "runtime: ${runtime}, pausing for 60secs..." sleep 10 done # & } DAILYTEMP(){ cw=35; echo echo -e "Sensor Temperature(s) Now / 1DayAVG / 7DayAVG" DIVIDER . . 60 for SENSORa in ${PW_SENSOR_ORD[@]}; do if [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "esxi" ]; then vHOST_TEMPNAMES=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSORa}]} .1.3.6.1.4.1.674.10892.5.4.700.20.1.8 -O vq | sed -e 's/"//g' | sed -e 's/ Temp//g') IFS=$'\n' read -rd '' -a SENSORS_CHECK <<<"${vHOST_TEMPNAMES}" unset IFS t=1 else SENSORS_CHECK=(${SENSORa}) fi for SENSOR in "${SENSORS_CHECK[@]}"; do if [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "mqtt" ]; then mqtt_message=`${mqtt_conn} -t tele/${SENSOR}/SENSOR -C 1` temp_c=$(echo ${mqtt_message} | cut -d':' -f 6 | cut -d',' -f 1) elif [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "system" ]; then temp_c=$(vcgencmd measure_temp) temp_c=${temp_c%\'*}; temp_c=${temp_c#*=} elif [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "remotesystem" ]; then temp_c=$(ssh root@${PW_REMOTE_SENSORS[${SENSOR}]} vcgencmd measure_temp) temp_c=${temp_c%\'*}; temp_c=${temp_c#*=} elif [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "esxi" ]; then temp_c=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSORa}]} .1.3.6.1.4.1.674.10892.5.4.700.20.1.6.1.${t} -O vq | sed -e 's/"//g') temp_c=`echo "scale=1; ${temp_c}/10" | bc` vSENSOR=${SENSOR} SENSOR="${SENSORa}-${vSENSOR// /_}" ((t++)) else temp_c='' fi if [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "esxi" ]; then average1=$(AVERAGETEMP ${PW_SENSOR_ID[${SENSORa}]} 1 ${vSENSOR// /_}) average7=$(AVERAGETEMP ${PW_SENSOR_ID[${SENSORa}]} 7 ${vSENSOR// /_}) else average1=$(AVERAGETEMP ${PW_SENSOR_ID[${SENSORa}]} 1) average7=$(AVERAGETEMP ${PW_SENSOR_ID[${SENSORa}]} 7) fi c=0; spc=''; spc1=`expr ${cw} - ${#SENSOR}`; until [ ${c} = ${spc1} ]; do spc="${spc} "; c=`expr ${c} + 1`; done if [ "${temp_c}" != "null" ] && [ "${temp_c}" != "" ]; then temp_f=`echo "scale=2; ${temp_c}*1.8 + 32" | bc` echo -e "${SENSOR}${spc}${temp_f}'F / ${average1}'F / ${average7}'F" else echo -e "${SENSOR}${spc}No Data" fi done [ "${temp_c}" != "null" ] && [ "${temp_c}" != "" ] && echo done } AVERAGEPOWER(){ watttotal=0 sensorid=${1} daysback=${2} logsfound=0; while IFS=$'\t' read date watt ;do watttotal=$(bc <<< "scale=2; ${watttotal}+${watt}") ((logsfound++)) done < <(${mysql_conn} -se "USE servermonitor; SELECT date,watt from power_data WHERE sensorid=${sensorid} AND date BETWEEN DATE_SUB(DATE(NOW()), INTERVAL ${daysback} DAY) AND NOW() ORDER BY id DESC;") [ "${logsfound}" != "0" ] && average=$(bc <<< "scale=2; ${watttotal}/${logsfound}") || average=0 # echo "$watttotal-$logsfound=${average}" # echo "${average}-(${logsfound})" echo ${average} } CHECKPOWER(){ start=`date +%s` rm -f ${PW_TMPFOLDER}/*.hostpower* while [ $# -gt 0 ]; do case "$1" in -a|-avg) avgdays=${2};; -o|-offsite) STYPE=offsite;; -m|-mainsite) STYPE=mainsite;; -e|-esxi) PTYPE=esxi;; -p|-power) PTYPE=power;; esac shift 1 done [ "${avgdays}" = "0" ] && unset avgdays [ "${avgdays}" != "" ] && avgdayshdr="${avgdays}-Day-Avg" || avgdayshdr="" if ([ "${STYPE}" == "" ] || [ "${STYPE}" == "mainsite" ]) && [ "${PTYPE}" != "esxi" ]; then echo DIVIDER . yellow 75 echo -e "${idsCL[Yellow]}Mainsite Power Information ${idsCL[LightYellow]}${avgdayshdr}" DIVIDER . yellow 75 echo -en "${idsCL[Yellow]}Pulling data from 'Powerwall' ... " INVSTATSINFO=$(curl -s "http://${PW_INVERTER_IP}/stats.json") if [ "${INVSTATSINFO}" != "" ]; then INPUTV=`echo ${INVSTATSINFO} | jq '.inputs .inV'` INPUTA=`echo ${INVSTATSINFO} | jq '.inputs .inA'` INV_ALARM=`echo ${INVSTATSINFO} | jq '.errors .Alms'` [ "${INV_ALARM}" == "0" ] && INV_ALARM_disp="${idsCL[Green]}No Alarms (${INV_ALARM})" || INV_ALARM_disp="${idsCL[LightRed]}${PW_INVERTER_ALARMS[${INV_ALARM}]}" INV_ERROR=`echo ${INVSTATSINFO} | jq '.errors .Err'` [ "${INV_ERROR}" == "0" ] && INV_ERROR_disp="${idsCL[Green]}No Errors (${INV_ERROR})" || INV_ERROR_disp="${idsCL[LightRed]}${PW_INVERTER_ERRORS[${INV_ERROR}]}" INV_STATE=`echo ${INVSTATSINFO} | jq '.stats .invSTATES'` [ "${INV_STATE}" != "0" ] && INV_STATE_disp="${idsCL[Green]}${PW_INVERTER_STATES[${INV_STATE}]}" || INV_STATE_disp="${idsCL[LightRed]}${PW_INVERTER_STATES[${INV_STATE}]}" INV_MODE=`echo ${INVSTATSINFO} | jq '.stats .power'` ([ "${INV_MODE}" != "3" ] && [ "${INV_MODE}" != "4" ] && [ "${INV_MODE}" != "E" ]) && INV_MODE_disp="${idsCL[Green]}${PW_INVERTER_MODES[${INV_MODE}]}" || INV_MODE_disp="${idsCL[LightRed]}${PW_INVERTER_MODES[${INV_MODE}]}" OUTPUTV=`echo ${INVSTATSINFO} | jq '.outputs .outV'` OUTPUTV2=`echo "scale=2; ${OUTPUTV}/2" | bc` OUTPUTA=`echo ${INVSTATSINFO} | jq '.outputs .outA'` OUTPUTA2=`echo "scale=2; ${OUTPUTA}*2" | bc` OUTPUTW=`echo ${INVSTATSINFO} | jq '.outputs .outW'` BATTV=`echo ${INVSTATSINFO} | jq '.inputs .battV'` BATTA=`echo ${INVSTATSINFO} | jq '.inputs .xfA'` BATTLIFE=`echo "scale=2; (${BATTV}*100)/${BATT_FULL}" | bc` if (( $(bc <<<"${BATTV} > ${FLOAT_CHARGE}") )); then if (( $(bc <<<"${BATTV} > ${BULK_CHARGE}") )); then BATTA_disp="${idsCL[Green]}`IDS_NUMBER_FORMAT ${BATTA}`'amps ${idsCL[LightCyan]}- Bulk Charging" else BATTA_disp="${idsCL[Green]}`IDS_NUMBER_FORMAT ${BATTA}`'amps ${idsCL[LightCyan]}- Float Charging" fi elif [ "${BATTA}" == "-0.1" ] || [ "${BATTA}" == "-0.2" ] || [ "${BATTA}" == "-0.3" ]; then BATTA_disp="${idsCL[LightCyan]}`IDS_NUMBER_FORMAT ${BATTA}`'amps ${idsCL[LightCyan]}- Standby" else BATTA_disp="${idsCL[LightRed]}`IDS_NUMBER_FORMAT ${BATTA}`'amps ${idsCL[LightCyan]}- Discharging" fi fi echo -en "\r\033[K" echo -e "${idsCL[White]}Inverter State ${idsCL[Default]}: ${INV_STATE_disp}" echo -e "${idsCL[White]}Inverter Mode ${idsCL[Default]}: ${INV_MODE_disp}" echo -e "${idsCL[White]}Inverter Alarms ${idsCL[Default]}: ${INV_ALARM_disp}" echo -e "${idsCL[White]}Inverter Errors ${idsCL[Default]}: ${INV_ERROR_disp}" echo echo -e "${idsCL[White]}Inverter Input Volts ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${INPUTV}`'volts" echo -e "${idsCL[White]}Inverter Input Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${INPUTA}`'amps" echo echo -e "${idsCL[White]}Inverter Output Volts ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OUTPUTV}`'volts / `IDS_NUMBER_FORMAT ${OUTPUTV2}`'volts" echo -e "${idsCL[White]}Inverter Output Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OUTPUTA}`'amps / `IDS_NUMBER_FORMAT ${OUTPUTA2}`'amps" echo -e "${idsCL[White]}Inverter Output Watts ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OUTPUTW}`'watts" echo echo -e "${idsCL[White]}Battery Voltage ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${BATTV}`'volts ~ `IDS_NUMBER_FORMAT ${BATTLIFE}`%" echo -e "${idsCL[White]}Battery Amps Chg/DChg ${idsCL[Default]}: ${BATTA_disp}${idsCL[Default]}" # echo DIVIDER . lightCyan 75 echo -en "${idsCL[Yellow]}Pulling data from 'ServerRoom' ... " # if [ "$(CHECK_HOST ${PW_UPS_IP})" != "false" ]; then SVRRM_VOLTIN=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.2.2.1.3.1.1 | sed 's/.*: //') SVRRM_VOLTIN=`echo "scale=2; ${SVRRM_VOLTIN}/10" | bc` SVRRM_VOLTOUT=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.3.2.1.2.1.1 | sed 's/.*: //') SVRRM_VOLTOUT=`echo "scale=2; ${SVRRM_VOLTOUT}/10" | bc` SVRRM_WATT=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.3.2.1.4.1.1 | sed 's/.*: //') SVRRM_AMP=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.3.2.1.3.1.1 | sed 's/.*: //') SVRRM_AMP=`echo "scale=2; ${SVRRM_AMP}/100" | bc` # fi # # if [ "$(CHECK_HOST ${PW_APCPDU_IP})" != "false" ]; then APCPDU_AMP=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.2.3.1.1.2.1 | sed 's/.*: //') APCPDU_AMP=`echo "scale=2; ${APCPDU_AMP}/10" | bc` APCPDU_WATT2=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.1.16.0 | sed 's/.*: //') APCPDU_WATT=`echo "scale=2; ${APCPDU_AMP}*${SVRRM_VOLTOUT}" | bc` # fi if [ "${SVRRM_VOLTOUT}" != "" ]; then if [ "${APCPDU_AMP}" != "" ]; then NETRK_AMP=`echo "scale=2; ${SVRRM_AMP}-${APCPDU_AMP}" | bc` NETRK_WATT=`echo "scale=2; ${SVRRM_WATT}-${APCPDU_WATT}" | bc` NETRK_WATT2=`echo "scale=2; ${SVRRM_WATT}-${APCPDU_WATT2}" | bc` fi VOLT_DROP=`echo "scale=1; ${OUTPUTV2}-${SVRRM_VOLTIN}" | bc` fi echo -en "\r\033[K" echo -e "${idsCL[White]}ServerRack Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${APCPDU_AMP}`'amps${idsCL[Default]}" MSG="${idsCL[White]}ServerRack Wattage ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${APCPDU_WATT}`'watts ${idsCL[Default]}~ estimate" echo -en "${MSG}" if [ "${avgdays}" != "" ]; then echo -en "${idsCL[LightYellow]} Calculating average ...${idsCL[Default]}" average=$(AVERAGEPOWER ${PW_POWERSENSOR_ID['server-rack']} ${avgdays}); average_disp="${idsCL[LightYellow]} `IDS_NUMBER_FORMAT ${average}`'watts" echo -en "\r\033[K"; echo -en "${MSG}${idsCL[LightYellow]}${average_disp}" else echo -en " ${idsCL[LightCyan]}(`IDS_NUMBER_FORMAT ${APCPDU_WATT2}` watts)" fi echo -e "${idsCL[Default]}" DIVIDER . lightCyan 75 echo -e "${idsCL[White]}NetworkRack Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${NETRK_AMP}`'amps ${idsCL[Default]}~ estimate${idsCL[Green]}${idsCL[Default]}" MSG="${idsCL[White]}NetworkRack Wattage ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${NETRK_WATT} 2 true`'watts ${idsCL[Default]}~ estimate" echo -en "${MSG}" if [ "${avgdays}" != "" ]; then echo -en "${idsCL[LightYellow]} Calculating average ...${idsCL[Default]}" average=$(AVERAGEPOWER ${PW_POWERSENSOR_ID['network-rack']} ${avgdays}); average_disp="${idsCL[LightYellow]} `IDS_NUMBER_FORMAT ${average}`'watts" echo -en "\r\033[K"; echo -en "${MSG}${idsCL[LightYellow]}${average_disp}" else echo -en " ${idsCL[LightCyan]}(`IDS_NUMBER_FORMAT ${NETRK_WATT2}` watts)" fi echo -e "${idsCL[Default]}" # echo DIVIDER . lightCyan 75 echo -e "${idsCL[White]}Server Room Voltage IN ${idsCL[Default]}: ${idsCL[Green]}${SVRRM_VOLTIN}'volts${idsCL[Default]}" echo -e "${idsCL[White]}Server Room Voltage OUT ${idsCL[Default]}: ${idsCL[Green]}${SVRRM_VOLTOUT}'volts${idsCL[Default]}" echo -e "${idsCL[LightCyan]}Voltage Drop ${idsCL[Default]}: ${idsCL[LightRed]}${VOLT_DROP}'volts${idsCL[Default]}" echo -e "${idsCL[White]}Server Room Amps ${idsCL[Default]}: ${idsCL[Green]}${SVRRM_AMP}'amps${idsCL[Default]}" MSG="${idsCL[White]}Server Room Wattage ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${SVRRM_WATT}`'watts" echo -en "${MSG}" if [ "${avgdays}" != "" ]; then echo -en "${idsCL[LightYellow]} Calculating average ...${idsCL[Default]}" average=$(AVERAGEPOWER ${PW_POWERSENSOR_ID['total']} ${avgdays}); average_disp="${idsCL[LightYellow]} `IDS_NUMBER_FORMAT ${average}`'watts" echo -en "\r\033[K"; echo -e "${MSG}${idsCL[LightYellow]}${average_disp}${idsCL[Default]}" else echo -e "${idsCL[Default]}" fi echo fi if ([ "${STYPE}" == "" ] || [ "${STYPE}" == "offsite" ]) && [ "${PTYPE}" != "esxi" ]; then DIVIDER . yellow 75 echo -e "${idsCL[Yellow]}Offsite Power Information ${idsCL[LightYellow]}${avgdayshdr}" DIVIDER . yellow 75 echo -en "${idsCL[Yellow]}Pulling data from 'Offsite' ... " upsinfo=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 admin@10.2.1.1 'upsc CP1500PFCLCD') if [ "$(echo "${upsinfo}" | grep 'input.voltage:')" != "" ]; then OFFSITE_VOLTIN=$(echo "${upsinfo}" | grep 'input.voltage:' | sed 's/.*: //') OFFSITE_VOLTOUT=$(echo "${upsinfo}" | grep 'output.voltage:' | sed 's/.*: //') OFFSITE_LOAD=$(echo "${upsinfo}" | grep 'ups.load:' | sed 's/.*: //') OFFSITE_LOAD=`echo "scale=2; ${OFFSITE_LOAD}/100" | bc` OFFSITE_WATTS=`echo "scale=2; ${OFFSITE_LOAD}*$(echo "${upsinfo}" | grep 'ups.realpower.nominal:' | sed 's/.*: //')" | bc` OFFSITE_AMPS=`echo "scale=2; ${OFFSITE_WATTS}/${OFFSITE_VOLTOUT}" | bc` (( $(bc <<<"${OFFSITE_AMPS} < 1") )) && [[ "${OFFSITE_AMPS}" = *"."* ]] && OFFSITE_AMPS="0${OFFSITE_AMPS}" OFFSITE_BATT_RUNTIME=$(echo "${upsinfo}" | grep 'battery.runtime:' | sed 's/.*: //') OFFSITE_BATT_RUNTIME=`echo "scale=2; ${OFFSITE_BATT_RUNTIME}/60" | bc` OFFSITE_BATT_CAP=$(echo "${upsinfo}" | grep 'battery.charge:' | sed 's/.*: //') # vHOSTFAN=$(ssh root@${PW_RACADM_ACCESS} racadm -r 10.2.1.21 -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1) # FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g') # OFFSITE_VOLTIN=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.4.1.3808.1.1.1.3.2.1.0 | sed 's/.*: //') # OFFSITE_VOLTIN=`echo "scale=2; ${OFFSITE_VOLTIN}/10" | bc` # OFFSITE_VOLTOUT=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.4.1.3808.1.1.1.4.2.1.0 | sed 's/.*: //') # OFFSITE_VOLTOUT=`echo "scale=2; ${OFFSITE_VOLTOUT}/10" | bc` # OFFSITE_LOAD=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.4.1.3808.1.1.1.4.2.3.0 | sed 's/.*: //') # OFFSITE_LOAD=`echo "scale=2; ${OFFSITE_LOAD}/100" | bc` # OFFSITE_WATTS=`echo "scale=2; ${OFFSITE_LOAD}*900" | bc` # OFFSITE_AMPS=`echo "scale=2; ${OFFSITE_WATTS}/${OFFSITE_VOLTOUT}" | bc` # OFFSITE_BATT_RUNTIME=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.2.1.33.1.2.3.0 | sed 's/.*: //') # OFFSITE_BATT_CAP=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.2.1.33.1.2.4.0 | sed 's/.*: //') fi echo -en "\r\033[K" echo -e "${idsCL[White]}UPS Voltage In ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OFFSITE_VOLTIN}`'volts${idsCL[Default]}" echo -e "${idsCL[White]}UPS Voltage Out ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OFFSITE_VOLTOUT}`'volts${idsCL[Default]}" echo echo -e "${idsCL[White]}Battery Capacity ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OFFSITE_BATT_CAP}`%${idsCL[Default]}" echo -e "${idsCL[White]}Battery Runtime ${idsCL[Default]}: ${idsCL[Green]}${OFFSITE_BATT_RUNTIME}'Mins${idsCL[Default]}" echo echo -e "${idsCL[White]}Total Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OFFSITE_AMPS}`'amps ${idsCL[Default]}~ estimate${idsCL[Green]}${idsCL[Default]}" MSG="${idsCL[White]}Total Wattage ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OFFSITE_WATTS}`'watts ${idsCL[Default]}~ estimate" echo -en "${MSG}" if [ "${avgdays}" != "" ]; then echo -en "${idsCL[LightYellow]} Calculating average ...${idsCL[Default]}" average=$(AVERAGEPOWER ${PW_POWERSENSOR_ID['offsite-ups']} ${avgdays}); average_disp="${idsCL[LightYellow]} `IDS_NUMBER_FORMAT ${average}`'watts" echo -en "\r\033[K"; echo -e "${MSG}${idsCL[LightYellow]}${average_disp}" fi echo -e "${idsCL[Default]}\n" # echo -e "${idsCL[LightCyan]}Current Fan Speed ${idsCL[Default]}: ${idsCL[Green]}${FanSpeed}'%${idsCL[Default]}" # echo fi if [ "${PTYPE}" != "power" ]; then DIVIDER . yellow 75 echo -e "${idsCL[Yellow]}ESXi Host Power Information ${avgdayshdr}" DIVIDER . yellow 75 for SENSOR in ${PW_SENSOR_ORD[@]}; do if [ "${PW_HOST_IDRACS[${SENSOR}]}" != "" ]; then gochk=0 if [ "${STYPE}" == "" ] || ([ "${STYPE}" == "mainsite" ] && [[ "${PW_HOST_IDRACS[${SENSOR}]}" = *"10.10."* ]]) || ([ "${STYPE}" == "offsite" ] && [[ "${PW_HOST_IDRACS[${SENSOR}]}" = *"10.2.1."* ]]); then gochk=1 fi if [ ${gochk} -eq 1 ]; then echo -en "${idsCL[Yellow]}Pulling data for '${SENSOR}' ... " HOST_WATT_SENSORS=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.8.1 -O vq 2> /dev/null | sed -e 's/"//g') IFS=$'\n' read -rd '' -a HOST_WATT_SENSORS <<<"${HOST_WATT_SENSORS}" unset IFS PS1='0.0'; PS2='0.0'; HOST_WATTS=0 if [ "${HOST_WATT_SENSORS}" != "" ]; then found=0 for s in {1..5}; do DP=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.8.1.${s} | sed 's/.*: //') if [[ "${DP}" = *"System Board"* ]]; then found=1 HOST_WATTS=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.6.1.${s} | sed 's/.*: //') elif [[ "${DP}" = *"PS1"* ]]; then PS1=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.6.1.${s} | sed 's/.*: //') elif [[ "${DP}" = *"PS2"* ]]; then PS2=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.6.1.${s} | sed 's/.*: //') fi done if [ ${found} -eq 1 ] && [ "${HOST_WATTS}" != "0" ] && [ "${HOST_WATTS}" != "" ]; then [ "${PS1}" != "0.0" ] && PS1=`echo "scale=1; ${PS1}/10" | bc` && (( $(bc <<<"${PS1} < 1") )) && [[ "${PS1}" = *"."* ]] && PS1="0${PS1}" [ "${PS2}" != "0.0" ] && PS2=`echo "scale=1; ${PS2}/10" | bc` && (( $(bc <<<"${PS2} < 1") )) && [[ "${PS2}" = *"."* ]] && PS2="0${PS2}" HOST_AMPS=`echo "scale=1; ${PS1}+${PS2}" | bc` HOST_WATTS_disp="${idsCL[Green]}${HOST_AMPS}'amps - `IDS_NUMBER_FORMAT ${HOST_WATTS}`'watts" elif [ "$(ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSOR}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" chassis power status | grep off)" != "" ]; then HOST_WATTS_disp="${idsCL[LightRed]}Host powered down" HOST_WATTS=-1 elif [ "${HOST_WATTS}" == "0" ]; then HOST_WATTS_disp="${idsCL[Yellow]}Host PSU not capable" else HOST_WATTS_disp="${idsCL[LightRed]}Could not pull data" fi [ "${HOST_WATTS}" == "" ] && HOST_WATTS=0 else HOST_WATTS_disp="${idsCL[LightRed]}Host offline" fi MSG="${idsCL[White]}${SENSOR} ${idsCL[Default]}: ${HOST_WATTS_disp}" echo -en "\r\033[K${MSG}" if [ "${avgdays}" != "" ] && [ ${HOST_WATTS} -gt 0 ]; then echo -en "${idsCL[LightYellow]} Calculating average ...${idsCL[Default]}" average=$(AVERAGEPOWER ${PW_POWERSENSOR_ID[${SENSOR}]} ${avgdays}); average_disp="${idsCL[LightYellow]} `IDS_NUMBER_FORMAT ${average}`'watts" echo -en "\r\033[K"; echo -en "${MSG}${idsCL[LightYellow]}${average_disp}" elif [ ${HOST_WATTS} -gt 0 ]; then echo -en "${idsCL[Cyan]} [PS1=${idsCL[LightCyan]}${PS1}'A${idsCL[Cyan]}, PS2=${idsCL[LightCyan]}${PS2}'A${idsCL[Cyan]}]" fi if [ "${PW_HOST_IDRACS[${SENSOR}]}" == "10.2.1.21" ] && [ ${HOST_WATTS} -ge 0 ]; then vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSOR}]} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.3 -O vq) FanSpeed=`echo "scale=2; ${vHOSTFAN}/21200" | bc`; FanSpeed=`echo "scale=0; ${FanSpeed}*100/1" | bc` # vHOSTFAN=$(ssh root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${SENSOR}]} -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1) # FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g') echo -en "${idsCL[LightCyan]} [FanSpeed=${FanSpeed}'%]" fi echo -e "${idsCL[Default]}" fi fi done fi end=`date +%s`; runtime=$((end-start)); echo -e "\nruntime: ${runtime}" [ "${PW_ACTION}" != "" ] && echo } CHECKPOWER_SERVICE(){ touch ${PW_TMPFOLDER}/power.ac.start touch ${PW_TMPFOLDER}/power.dc.start while true; do INVSTATSINFO=$(curl -s "http://${PW_INVERTER_IP}/stats.json") SVRRM_UPS_INPUTACV=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.2.2.1.3.1.1 | sed 's/.*: //') if (( $(bc <<<"${SVRRM_UPS_INPUTACV} < ${min_acvolt}") )); then if [ ! -f ${PW_TMPFOLDER}/power.ups.low ]; then touch ${PW_TMPFOLDER}/power.ups.low elif [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/power.ups.low)) -ge 60 ]; then SENDNOTICE "POWER ALERT - UPS POWER OFF/LOW POWER!!" "UPS has no power for 1min, shutting all servers down!" 1 ######################### FINISH fi elif [ -f ${PW_TMPFOLDER}/power.ups.low ]; then rm -f ${PW_TMPFOLDER}/power.ups.low fi if [ "${INVSTATSINFO}" != "" ]; then INPUTACV=$(echo ${INVSTATSINFO} | jq '.inputs .inV') BATTVOLT=$(echo ${INVSTATSINFO} | jq '.inputs .battV') [ ! "${last_battvolt}" ] && last_battvolt=${BATTVOLT} if (( $(bc <<<"${INPUTACV} >= ${min_acvolt}") )); then [ "${last_battvolt}" != "${BATTVOLT}" ] && last_battvolt=${BATTVOLT} if [ -f ${PW_TMPFOLDER}/power.ac.low ]; then echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${INPUTACV}'volts / ${BATTVOLT}'volts - Back to Normal Voltage" >> ${PW_LOGPOWER} SENDNOTICE "POWER NOMINAL AGAIN" "Normal voltage detected VOLTAGE: ${INPUTACV}'volts" else [ $(expr `date +%s` - $(stat -c %Y ${PW_LOGPOWER})) -ge $(echo "scale=0; ${PW_LOG_INTERVAL_NORMAL}*60" | bc) ] && echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${INPUTACV}'volts - Normal Voltage" >> ${PW_LOGPOWER} if [ -f ${PW_TMPFOLDER}/power.ac.start ]; then SENDNOTICE "Power Nominal" "Service Startup Normal voltage detected VOLTAGE: ${INPUTACV}'volts BATT VOLTAGE: ${BATTVOLT}'volts" echo "($(date +'%Y-%m-%d %H:%M:%S')) - Input: ${INPUTACV}'volts - 'Check Power' Service Startup - Normal voltage detected" >> ${PW_LOGFILE} echo "($(date +'%Y-%m-%d %H:%M:%S')) - Input: ${INPUTACV}'volts - 'Check Power' Service Startup - Normal voltage detected" >> ${PW_LOGPOWER} rm -f ${PW_TMPFOLDER}/power.ac.start fi fi if [ ! -f ${PW_TMPFOLDER}/power.ac.good ]; then if [ -f ${PW_TMPFOLDER}/power.sys.off ] || [ -f ${PW_TMPFOLDER}/power.main.off ] || [ -f ${PW_TMPFOLDER}/power.ac.conserve ]; then SENDNOTICE "HOSTS POWER" "Power restored! Will wait ${PW_WAIT_TO_POWER_SERVERS}'mins before turning host(s) back on" touch ${PW_TMPFOLDER}/.power.restored fi rm -f ${PW_TMPFOLDER}/power.ac.* touch ${PW_TMPFOLDER}/power.ac.good elif [ -f ${PW_TMPFOLDER}/.power.restored ] && [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/.power.restored)) -ge $(echo "scale=0; ${PW_WAIT_TO_POWER_SERVERS}*60" | bc) ]; then HOSTMGMT mainsite -p on >/dev/null 2>&1 rm -f ${PW_TMPFOLDER}/.power.restored fi # UPDATE APC-PDU LINE TO LINE VOLTAGE CURRENT_VOLTAGE=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.1.15.0 | sed 's/.*: //') SET_VOLTAGE=`echo "scale=2; $(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.3.2.1.2.1.1 | sed 's/.*: //')/10" | bc | awk '{print int($1+0.5)}'` [ "${SET_VOLTAGE}" ] && [ ${CURRENT_VOLTAGE} -ne ${SET_VOLTAGE} ] && run=$(snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.1.15.0 i ${SET_VOLTAGE} >/dev/null 2>&1) && echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${CURRENT_VOLTAGE}'volts --> ${SET_VOLTAGE}'volts - LINE-TO-LINE VOLTAGE UPDATED ON APC-PDU" >> ${PW_LOGPOWER} else [ $(expr `date +%s` - $(stat -c %Y ${PW_LOGPOWER})) -ge 300 ] && echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${INPUTACV}'volts / ${BATTVOLT}'volts - Power OFF or LOW" >> ${PW_LOGPOWER} if [ -f ${PW_TMPFOLDER}/power.ac.good ]; then echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${INPUTACV}'volts / ${BATTVOLT}'volts - Power OFF or LOW voltage detected" >> ${PW_LOGPOWER} SENDNOTICE "POWER ALERT - POWER OFF/LOW!!" "Power off or low voltage detected VOLTAGE: ${INPUTACV}'volts BATT VOLTAGE: ${BATTVOLT}'volts" 1 rm -f ${PW_TMPFOLDER}/power.ac.good touch ${PW_TMPFOLDER}/power.ac.low ##### SHUTDOWN OFFSITE SERVER WHILE ITS AT MAINSITE SHUTDOWN_SERVERS2 10.2.1.11 & fi if [ ! -f ${PW_TMPFOLDER}/power.ac.conserve ] && [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/power.ac.low)) -ge $(echo "scale=0; ${PW_CONSERVE_AFTER}*60" | bc) ]; then echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${INPUTACV}'volts / ${BATTVOLT}'volts - Shutting down iSCSI VM's and Host to conserve power" >> ${PW_LOGPOWER} SENDNOTICE "POWER ALERT - Conserving Power" "Shutting down iSCSI VM's and Host to conserve power" 1 SHUTDOWN_SERVERS2 ${PW_HOST_IDRACS['iDS-vMS-Host0']} & touch ${PW_TMPFOLDER}/power.ac.conserve fi fi if (( $(bc <<<"${BATTVOLT} >= ${min_battvolt}") )); then [ $(expr `date +%s` - $(stat -c %Y ${PW_LOGPOWER})) -ge $(echo "scale=0; ${PW_LOG_INTERVAL_NORMAL}*60" | bc) ] && echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - Battery Voltage" >> ${PW_LOGPOWER} if [ -f ${PW_TMPFOLDER}/power.dc.start ]; then echo "($(date +'%Y-%m-%d %H:%M:%S')) - Battery: ${BATTVOLT}'volts - Service Startup - Normal voltage detected" >> ${PW_LOGPOWER} rm -f ${PW_TMPFOLDER}/power.dc.start fi if [ ! -f ${PW_TMPFOLDER}/power.dc.good ]; then rm -f ${PW_TMPFOLDER}/power.dc.* touch ${PW_TMPFOLDER}/power.dc.good fi else [ -f ${PW_TMPFOLDER}/power.dc.good ] && rm -f ${PW_TMPFOLDER}/power.dc.good [ $(expr `date +%s` - $(stat -c %Y ${PW_LOGPOWER})) -ge $(echo "scale=0; ${PW_LOG_INTERVAL_ABNORMAL}*60" | bc) ] && echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - LOW BATTERY Voltage" >> ${PW_LOGPOWER} if (( $(bc <<<"${BATTVOLT} <= ${min_battvolt_sys}") )); then [ ! -f ${PW_TMPFOLDER}/power.dc.critlow ] && touch ${PW_TMPFOLDER}/power.dc.critlow if [ ! -f ${PW_TMPFOLDER}/power.sys.off ] && (( $(bc <<<"${INPUTACV} < ${min_acvolt}") )); then echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - Shutting down all remaining servers..." >> ${PW_LOGFILE} echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - Shutting down all remaining servers..." >> ${PW_LOGPOWER} SENDNOTICE "BATT-VOLT REALLY LOW: SHUTDOWN SYS SERVERS" "Battery Voltage REALLY LOW: ${BATTVOLT}'volts Shutting down all remaining servers" 1 SHUTDOWN_SYS POWER & fi elif (( $(bc <<<"${BATTVOLT} < ${min_battvolt}") )); then [ ! -f ${PW_TMPFOLDER}/power.dc.low ] && touch ${PW_TMPFOLDER}/power.dc.low if [ ! -f ${PW_TMPFOLDER}/power.main.off ] && (( $(bc <<<"${INPUTACV} < ${min_acvolt}") )); then echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - Shutting down main servers..." >> ${PW_LOGFILE} echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - Shutting down main servers..." >> ${PW_LOGPOWER} SENDNOTICE "BATT-VOLT LOW: SHUTDOWN MAIN SERVERS" "Battery Voltage LOW: ${BATTVOLT}'volts Shutting down main servers" 1 SHUTDOWN_MAIN POWER & fi elif [ ! -f ${PW_TMPFOLDER}/power.main.off ] && [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/power.dc.low)) -ge $(echo "scale=0; ${PW_SHUTDOWN_MAINSERVERS_AFTER}*60" | bc) ]; then echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - Shutting down main servers..." >> ${PW_LOGFILE} echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - Shutting down main servers..." >> ${PW_LOGPOWER} SENDNOTICE "BATT-VOLT LOW: SHUTDOWN MAIN SERVERS" "Battery Voltage LOW: ${BATTVOLT}'volts Shutting down main servers" 1 SHUTDOWN_MAIN POWER & fi volt_diff=`echo "scale=1; ${last_battvolt}-${BATTVOLT}" | bc` (( $(bc <<<"${volt_diff} < 0") )) && volt_diff=`echo "scale=1; ${volt_diff} * -1" | bc` if (( $(bc <<<"${volt_diff} > 0.5") )); then SENDNOTICE "BATTERY VOLTAGE CHANGE" "Battery Voltage: ${BATTVOLT}'volts" echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${BATTVOLT}'volts - Battery Voltage Change" >> ${PW_LOGPOWER} last_battvolt=${BATTVOLT} fi fi else sleep 20s fi ######offsite check # if [ "$(CHECK_HOST 10.2.1.1)" != "false" ]; then # upsinfo=$(ssh admin@10.2.1.1 'upsc CP1500PFCLCD') # OFFSITE_VOLTIN=$(echo "${upsinfo}" | grep 'input.voltage:' | sed 's/.*: //') # OFFSITE_BATT_RUNTIME=$(echo "${upsinfo}" | grep 'battery.runtime:' | sed 's/.*: //') # OFFSITE_BATT_RUNTIME=`echo "scale=2; ${OFFSITE_BATT_RUNTIME}/60" | bc` # OFFSITE_BATT_CAP=$(echo "${upsinfo}" | grep 'battery.charge:' | sed 's/.*: //') # # if (( $(bc <<<"${OFFSITE_VOLTIN} >= ${min_acvolt}") )); then # if [ -f ${PW_TMPFOLDER}/power.offsite.ac.low ]; then # echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${OFFSITE_VOLTIN}'volts - Offsite Back to Normal Voltage" >> ${PW_LOGPOWER} # echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${OFFSITE_VOLTIN}'volts - OFFSITE POWER NOMINAL AGAIN" >> ${PW_LOGFILE} # SENDNOTICE "OFFSITE POWER NOMINAL AGAIN" "Normal voltage detected # VOLTAGE: ${OFFSITE_VOLTIN}'volts" # rm -f ${PW_TMPFOLDER}/power.offsite.ac.* # fi # if [ -f ${PW_TMPFOLDER}/power.offsite.off ]; then # if [ ! -f ${PW_TMPFOLDER}/power.offsite.restored ]; then # touch ${PW_TMPFOLDER}/power.offsite.restored # # elif [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/power.offsite.restored)) -ge 60 ]; then # SENDNOTICE "OFFSITE HOST POWER" "Powering offsite host(s) back on after power was restored" # for offsite_host in "${PW_OFFSITEHOSTS[@]}"; do # HOSTPOWER ${offsite_host} on >/dev/null 2>&1 # done # rm -f ${PW_TMPFOLDER}/power.offsite.* # fi # # else # [ $(expr `date +%s` - $(stat -c %Y ${PW_LOGPOWER})) -le 300 ] && echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${OFFSITE_VOLTIN}'volts - Offsite Normal Voltage" >> ${PW_LOGPOWER} # fi # else # echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${OFFSITE_VOLTIN}'volts - OFFSITE POWER OFF/LOW POWER" >> ${PW_LOGPOWER} # echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${OFFSITE_VOLTIN}'volts - OFFSITE POWER OFF/LOW POWER" >> ${PW_LOGFILE} # # if [ ! -f ${PW_TMPFOLDER}/power.offsite.ac.low ] || [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/power.offsite.ac.low)) -ge 240 ]; then # SENDNOTICE "OFFSITE POWER ALERT - POWER OFF/LOW!!" "Power off or low voltage detected # BATT CAPACITY: ${OFFSITE_BATT_CAP}'%25 # BATT RUNTIME: ${OFFSITE_BATT_RUNTIME}'Mins" 1 # touch ${PW_TMPFOLDER}/power.offsite.ac.low # fi # # if (( $(bc <<<"${OFFSITE_BATT_CAP} <= 95") )) && [ ! -f ${PW_TMPFOLDER}/power.offsite.off ]; then # SENDNOTICE "OFFSITE HOST POWER" "Powering DOWN offsite host(s) due to power outage" 1 # SHUTDOWN_OFFSITE & # touch ${PW_TMPFOLDER}/power.offsite.off # fi # fi # # # fi sleep 10s done # & } POWERLOGGER_SERVICE(){ while true; do LogDataTime=`date +'%Y-%m-%d %H:%M:%S'` INVSTATSINFO=$(curl -s "http://${PW_INVERTER_IP}/stats.json") if [ "${INVSTATSINFO}" != "" ]; then INPUTV=`echo ${INVSTATSINFO} | jq '.inputs .inV'` INPUTA=`echo ${INVSTATSINFO} | jq '.inputs .inA'` OUTPUTV=`echo ${INVSTATSINFO} | jq '.outputs .outV'` OUTPUTA=`echo ${INVSTATSINFO} | jq '.outputs .outA'` OUTPUTW=`echo ${INVSTATSINFO} | jq '.outputs .outW'` BATTV=`echo ${INVSTATSINFO} | jq '.inputs .battV'` BATTA=`echo ${INVSTATSINFO} | jq '.inputs .xfA'` QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`volt\`, \`amp\`) VALUES ('${PW_POWERSENSOR_ID['inv-in']}','${LogDataTime}','${INPUTV}','${INPUTA}')" ${mysql_conn} -e "USE servermonitor; ${QRY}" QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`volt\`, \`amp\`, \`watt\`) VALUES ('${PW_POWERSENSOR_ID['inv-out']}','${LogDataTime}','${OUTPUTV}','${OUTPUTA}','${OUTPUTW}')" ${mysql_conn} -e "USE servermonitor; ${QRY}" QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`volt\`, \`amp\`) VALUES ('${PW_POWERSENSOR_ID['battery']}','${LogDataTime}','${BATTV}','${BATTA}')" ${mysql_conn} -e "USE servermonitor; ${QRY}" QRY="INSERT INTO inv_jsonstats (\`date\`, \`data\`) VALUES ('${LogDataTime}','${INVSTATSINFO}')" ${mysql_conn} -e "USE servermonitor; ${QRY}" fi if [ "$(CHECK_HOST ${PW_UPS_IP})" != "false" ]; then SVRRM_VOLT=$(snmpwalk -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.3.2.1.2.1.1 | sed 's/.*: //') SVRRM_VOLT=`echo "scale=1; ${SVRRM_VOLT}/10" | bc` SVRRM_WATT=$(snmpwalk -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.3.2.1.4.1.1 | sed 's/.*: //') SVRRM_AMP=$(snmpwalk -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.3.2.1.3.1.1 | sed 's/.*: //') SVRRM_AMP=`echo "scale=2; ${SVRRM_AMP}/100" | bc` QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`volt\`, \`amp\`, \`watt\`) VALUES ('${PW_POWERSENSOR_ID['total']}','${LogDataTime}','${SVRRM_VOLT}','${SVRRM_AMP}','${SVRRM_WATT}')" ${mysql_conn} -e "USE servermonitor; ${QRY}" fi if [ "$(CHECK_HOST ${PW_APCPDU_IP})" != "false" ]; then APCPDU_AMP=$(snmpwalk -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.2.3.1.1.2.1 | sed 's/.*: //') APCPDU_AMP=`echo "scale=1; ${APCPDU_AMP}/10" | bc` if [ "${SVRRM_VOLT}" != "" ]; then APCPDU_WATT=`echo "scale=2; ${APCPDU_AMP}*${SVRRM_VOLT}" | bc` QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`volt\`, \`amp\`, \`watt\`) VALUES ('${PW_POWERSENSOR_ID['server-rack']}','${LogDataTime}','${SVRRM_VOLT}','${APCPDU_AMP}','${APCPDU_WATT}')" else QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`amp\`) VALUES ('12','${LogDataTime}','${APCPDU_AMP}')" fi ${mysql_conn} -e "USE servermonitor; ${QRY}" fi if [ "${SVRRM_VOLT}" != "" ] && [ "${APCPDU_AMP}" != "" ]; then NETRK_AMP=`echo "scale=2; ${SVRRM_AMP}-${APCPDU_AMP}" | bc` NETRK_WATT=`echo "scale=0; ${SVRRM_WATT}-${APCPDU_WATT}" | bc` QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`volt\`, \`amp\`, \`watt\`) VALUES ('${PW_POWERSENSOR_ID['network-rack']}','${LogDataTime}','${SVRRM_VOLT}','${NETRK_AMP}','${NETRK_WATT}')" ${mysql_conn} -e "USE servermonitor; ${QRY}" fi upsinfo=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 admin@10.2.1.1 'upsc CP1500PFCLCD') if [ "$(echo "${upsinfo}" | grep 'input.voltage:')" != "" ]; then OFFSITE_VOLTOUT=$(echo "${upsinfo}" | grep 'output.voltage:' | sed 's/.*: //') OFFSITE_LOAD=$(echo "${upsinfo}" | grep 'ups.load:' | sed 's/.*: //') OFFSITE_LOAD=`echo "scale=2; ${OFFSITE_LOAD}/100" | bc` OFFSITE_WATTS=`echo "scale=2; ${OFFSITE_LOAD}*$(echo "${upsinfo}" | grep 'ups.realpower.nominal:' | sed 's/.*: //')" | bc` OFFSITE_AMPS=`echo "scale=2; ${OFFSITE_WATTS}/${OFFSITE_VOLTOUT}" | bc` QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`volt\`, \`amp\`, \`watt\`) VALUES ('${PW_POWERSENSOR_ID['offsite-ups']}','${LogDataTime}','${OFFSITE_VOLTOUT}','${OFFSITE_AMPS}','${OFFSITE_WATTS}')" ${mysql_conn} -e "USE servermonitor; ${QRY}" fi for SENSOR in ${PW_SENSOR_ORD[@]}; do if [ "${PW_HOST_IDRACS[${SENSOR}]}" != "" ]; then HOST_WATT_SENSORS=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.8.1 -O vq | sed -e 's/"//g') if [ "${HOST_WATT_SENSORS}" != "" ]; then IFS=$'\n' read -rd '' -a HOST_WATT_SENSORS <<<"${HOST_WATT_SENSORS}" unset IFS for s in {1..5}; do if [[ "$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.8.1.${s} | sed 's/.*: //')" = *"System Board"* ]]; then HOST_WATTS=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.6.1.${s} | sed 's/.*: //') if [[ "${HOST_WATTS}" != *"Timeout"* ]] && [ "${HOST_WATTS}" != "0" ]; then QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`watt\`) VALUES ('${PW_POWERSENSOR_ID[${SENSOR}]}','${LogDataTime}','${HOST_WATTS}')" ${mysql_conn} -e "USE servermonitor; ${QRY}" fi break fi done fi fi done if [ "$(compgen -G "${PW_TMPFOLDER}/temp.*")" != "" ] || [ "$(compgen -G "${PW_TMPFOLDER}/power.*")" != "" ]; then sleep ${PW_MYSQL_LOG_INTERVAL_ABNORMAL}m else sleep ${PW_MYSQL_LOG_INTERVAL_NORMAL}m fi done } RESTARTALL_SERVICES(){ STOPALL_SERVICES sleep 10s STARTALL_SERVICES } STOPALL_SERVICES(){ for srvc in "${!PW_POWERWALL_SERVICES[@]}"; do SERVICE_MNG ${srvc} stop done } STARTALL_SERVICES(){ for srvc in "${!PW_POWERWALL_SERVICES[@]}"; do SERVICE_MNG ${srvc} start done } SERVICE_MNG(){ if [ "${2}" = "start" ]; then sa=Starting elif [ "${2}" = "stop" ]; then sa=Stopping elif [ "${2}" = "restart" ]; then sa=Restarting elif [ "${2}" = "status" ]; then sa='Status for' fi echo -en "${idsCL[LightCyan]}${sa} ${PW_POWERWALL_SERVICES[${1}]} Service ... " /bin/systemctl ${2} ${PW_POWERWALL_SERVICES[${1}]} echo -e "${idsCL[Green]}Done${idsCL[Default]}" } STOP_SERVICE(){ echo "stop: ${1}" ps -ef | grep "powerwall.*service ${1} start" | grep -v "grep" | awk '{print $2}' | xargs kill } CHECK_SERVICES(){ echo echo -e "${idsCL[Yellow]}PowerWall Monitor Service Status" DIVIDER . yellow 75 for srvc in "${PW_POWERWALL_SERVICES[@]}"; do c=0; spc=''; spc1=`expr 25 - ${#srvc}`; until [ ${c} = ${spc1} ]; do spc="${spc} "; c=`expr ${c} + 1`; done echo -en "${idsCL[LightCyan]}${srvc}${spc}: " [ "$(systemctl is-active ${srvc})" == "active" ] && echo -en "${idsCL[Green]}Running" || echo -en "${idsCL[Yellow]}Not Running" echo -e "${idsCL[Default]}" done echo } SHUTDOWN_MAIN(){ if [ "${1}" == "ServerRoomTH" ] || [ "${1}" == "TEMP" ]; then # SHUTDOWN_SERVERS MAIN ${1} SHUTDOWN_SERVER2 main # HOSTMGMT main -e off >/dev/null 2>&1 reason='Server Room Overheated!' sendnotice=true elif [ "${1}" == "POWER" ]; then # SHUTDOWN_SERVERS MAIN ${1} SHUTDOWN_SERVER2 main # HOSTMGMT main -e off >/dev/null 2>&1 reason='Low Power!' sendnotice=true else sendnotice=false fi if [ "${sendnotice}" == "true" ]; then SENDNOTICE "MAIN SERVERS SHUTDOWN" "MAIN servers have been shutdown ${reason}" 1 echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - Main servers have been shutdown, ${reason}" >> ${PW_LOGFILE} fi echo } SHUTDOWN_SYS(){ if [ "${1}" == "ServerRoomTH" ] || [ "${1}" == "TEMP" ]; then # SHUTDOWN_SERVERS SYS ${1} [ ! -f ${PW_TMPFOLDER}/shutdown.MAIN ] && SHUTDOWN_SERVER2 mainsite || SHUTDOWN_SERVER2 sys # HOSTMGMT sys -e off >/dev/null 2>&1 reason='Server Room Overheated!' sendnotice=true elif [ "${1}" == "POWER" ]; then # SHUTDOWN_SERVERS SYS ${1} [ ! -f ${PW_TMPFOLDER}/shutdown.MAIN ] && SHUTDOWN_SERVER2 mainsite || SHUTDOWN_SERVER2 sys # HOSTMGMT sys -e off >/dev/null 2>&1 reason='Low Power!' sendnotice=true else sendnotice=false fi if [ "${sendnotice}" == "true" ]; then SENDNOTICE "SYS SERVERS SHUTDOWN" "SYS servers have been shutdown ${reason}" 1 echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - SYS servers have been shutdown, ${reason}" >> ${PW_LOGFILE} echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${temp_f}'F - Shutting down SYS servers" >> ${logtemp} fi # curl --data "cmd=PWRoff" http://${PW_INVERTER_IP}/cmd echo } SHUTDOWN_CRIT(){ if [ "${1}" == "Powerwall-CPU" ]; then SENDNOTICE "${1} TEMP CRITICAL" "Powerwall System shutting down" 1 echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - CRITICAL TEMP - Powerwall System shutting down" >> ${PW_LOGFOLDER}/log-temp-${1} echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${1} TEMP CRITICAL - Powerwall System shutting down" >> ${PW_LOGFILE} sleep 1s /sbin/poweroff elif [ "${1}" == "OctoPi-CPU" ]; then SENDNOTICE "${1} TEMP CRITICAL" "OctoPi System shutting down" 1 echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - CRITICAL TEMP - OctoPi System shutting down" >> ${PW_LOGFOLDER}/log-temp-${1} echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${1} TEMP CRITICAL - OctoPi System shutting down" >> ${PW_LOGFILE} sleep 1s ssh root@${PW_REMOTE_SENSORS[${1}]} /sbin/poweroff elif [ "${1}" == "OctoPi-CPU-Usage" ]; then SENDNOTICE "${1} USAGE CRITICAL" "OctoPi System rebooting" 1 echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - CRITICAL USAGE - OctoPi System rebooting" >> ${PW_LOGFOLDER}/log-temp-${1} echo -e "($(date +'%Y-%m-%d %H:%M:%S')) - ${1} USAGE CRITICAL - OctoPi System rebooting" >> ${PW_LOGFILE} ssh root@${PW_REMOTE_SENSORS[${1}]} /sbin/reboot fi } SHUTDOWN_OFFSITE(){ if [ ! -f ${PW_TMPFOLDER}/power.offsite.off ]; then SENDNOTICE "OFFSITE SHUTDOWN - POWER OFF/LOW!!" "Shutting down offsite host(s)" 1 for offsite_host in "${PW_OFFSITEHOSTS[@]}"; do SHUTDOWN_SERVER ${offsite_host} & done touch ${PW_TMPFOLDER}/power.offsite.off fi } SHUTDOWN_SERVERS(){ echo "($(date +'%Y-%m-%d %H:%M:%S')) - Shutting down ${1} servers" >> ${PW_LOGFILE} [ "${TEST}" == "true" ] && echo "RUNNING IN TEST MODE">>${PW_LOGFILE} if [ "${1^^}" == "MAIN" ]; then if [ ! -f ${PW_TMPFOLDER}/power.main.off ]; then touch ${PW_TMPFOLDER}/power.main.off if [ "${2}" != "maintenance" ]; then MSG="Disabling CLS in vCenter" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(ssh root@${PW_VCENTERHOST} "sed -i '//{n;s/.*<\/enabled>/False<\/enabled>/}' /etc/vmware-vpx/vpxd.cfg >/dev/null 2>&1" >/dev/null 2>&1) run=$(ssh root@${PW_VCENTERHOST} "service-control --stop vmware-vpxd >/dev/null 2>&1" >/dev/null 2>&1) run=$(ssh root@${PW_VCENTERHOST} "service-control --start vmware-vpxd >/dev/null & 2>&1" >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}\n" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi echo fi for ESXIHOST in "${PW_MAINHOSTS[@]}"; do MSG="Stopping iSCSI-PRI VM's on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo for ESXIHOST in "${PW_MAINHOSTS[@]}"; do MSG="Enabling Maintenance Mode on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(${PW_FOLDER}/esxi-scripts/host-maintenance_mode.ps1 ${ESXIHOST} & >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo for ESXIHOST in "${PW_MAINHOSTS[@]}"; do MSG="Verifying iSCSI-PRI VM's stopped on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown-verify.ps1 ${ESXIHOST} >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo for ESXIHOST in "${PW_MAINHOSTS[@]}"; do MSG="Stopping Remaining VM's on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(${PW_FOLDER}/esxi-scripts/vm-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1) run=$(${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo if [ "${2}" != "maintenance" ]; then for ESXIHOST in "${PW_MAINHOSTS[@]}"; do MSG="Wait for VM's to power off, then shutdown '${PW_ESXI_HOST_NAMES[${ESXIHOST}]}'" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then MAINT_MODE_VERIFY_SHUTDOWN ${ESXIHOST} & echo -e "${idsCL[Green]}Continuing in background\n" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo MSG="Waiting for iSCSI-PRI Host to shutdown" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then while ping -qw 10 -c3 "10.10.2.10">/dev/null 2>&1; do sleep 1; done echo -e "${idsCL[Green]}Done${idsCL[Default]}\n" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi MSG="Powering OFF the SAS Enclosure" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then if [ "$(CHECK_HOST 10.10.2.10)" == "false" ]; then run=$(snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.14 i 2 >/dev/null 2>&1) sleep 3s echo -e "${idsCL[Green]}Done${idsCL[Default]}\n" else echo -e "${idsCL[LightRed]}'${PW_iDRACHOST_SHORTNAMES[${idracip}]}' is not offline, not powering down\n" fi else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi echo fi fi elif [ "${1^^}" == "SYS" ]; then [ ! -f ${PW_TMPFOLDER}/power.main.off ] && [ "${2}" == "TEMP" ] && SHUTDOWN_SERVERS MAIN TEMP if [ ! -f ${PW_TMPFOLDER}/power.sys.off ]; then touch ${PW_TMPFOLDER}/power.sys.off if [ "${2}" != "maintenance" ]; then MSG="Disabling CLS in vCenter" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(ssh root@${PW_VCENTERHOST} "sed -i '//{n;s/.*<\/enabled>/False<\/enabled>/}' /etc/vmware-vpx/vpxd.cfg >/dev/null 2>&1" >/dev/null 2>&1) run=$(ssh root@${PW_VCENTERHOST} "service-control --stop vmware-vpxd >/dev/null 2>&1" >/dev/null 2>&1) run=$(ssh root@${PW_VCENTERHOST} "service-control --start vmware-vpxd >/dev/null 2>&1" >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi echo fi for ESXIHOST in "${PW_SYSHOSTS[@]}"; do MSG="Stopping iSCSI-SYS VM's on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then ${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1 echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo for ESXIHOST in "${PW_SYSHOSTS[@]}"; do MSG="Enabling Maintenance Mode on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(${PW_FOLDER}/esxi-scripts/host-maintenance_mode.ps1 ${ESXIHOST} & >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo for ESXIHOST in "${PW_SYSHOSTS[@]}"; do MSG="Verifying iSCSI-SYS VM's stopped on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown-verify.ps1 ${ESXIHOST} >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo for ESXIHOST in "${PW_SYSHOSTS[@]}"; do MSG="Stopping Remaining VM's on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then ${PW_FOLDER}/esxi-scripts/vm-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1 ${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1 echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo if [ "${2}" != "maintenance" ]; then for ESXIHOST in "${PW_SYSHOSTS[@]}"; do MSG="Wait for VM's to power off, then shutdown '${PW_ESXI_HOST_NAMES[${ESXIHOST}]}'" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then MAINT_MODE_VERIFY_SHUTDOWN ${ESXIHOST} & echo -e "${idsCL[Green]}Continuing in background\n" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo fi fi elif [ "${1^^}" == "ALL" ]; then if [ ! -f ${PW_TMPFOLDER}/power.all.off ]; then touch ${PW_TMPFOLDER}/power.all.off if [ "${2}" != "maintenance" ]; then MSG="Disabling CLS in vCenter" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(ssh root@${PW_VCENTERHOST} "sed -i '//{n;s/.*<\/enabled>/False<\/enabled>/}' /etc/vmware-vpx/vpxd.cfg >/dev/null 2>&1" >/dev/null 2>&1) run=$(ssh root@${PW_VCENTERHOST} "sed -i '//{n;s/.*<\/enabled>/False<\/enabled>/}' /etc/vmware-vpx/vpxd.cfg >/dev/null 2>&1" >/dev/null 2>&1) run=$(ssh root@${PW_VCENTERHOST} "service-control --stop vmware-vpxd >/dev/null 2>&1" >/dev/null 2>&1) run=$(ssh root@${PW_VCENTERHOST} "service-control --start vmware-vpxd >/dev/null 2>&1" >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi echo fi for ESXIHOST in "${PW_ALLHOSTS[@]}"; do MSG="Stopping all iSCSI VM's on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then ${PW_FOLDER}/esxi-scripts/iscsi-all-vm-shutdown.ps1 ${ESXIHOST} & >/dev/null 2>&1 echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo for ESXIHOST in "${PW_ALLHOSTS[@]}"; do MSG="Enabling Maintenance Mode on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(${PW_FOLDER}/esxi-scripts/host-maintenance_mode.ps1 ${ESXIHOST} & >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo for ESXIHOST in "${PW_ALLHOSTS[@]}"; do MSG="Verifying iSCSI VM's stopped on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(${PW_FOLDER}/esxi-scripts/iscsi-all-vm-shutdown-verify.ps1 ${ESXIHOST} >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo for ESXIHOST in "${PW_ALLHOSTS[@]}"; do MSG="Stopping Remaining VM's on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then ${PW_FOLDER}/esxi-scripts/vm-shutdown.ps1 ${ESXIHOST} & >/dev/null 2>&1 ${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${ESXIHOST} & >/dev/null 2>&1 echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo if [ "${2}" != "maintenance" ]; then for ESXIHOST in "${PW_ALLHOSTS[@]}"; do MSG="Wait for VM's to power off, then shutdown '${PW_ESXI_HOST_NAMES[${ESXIHOST}]}'" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then MAINT_MODE_VERIFY_SHUTDOWN ${ESXIHOST} & echo -e "${idsCL[Green]}Continuing in background\n" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo MSG="Waiting for iSCSI-PRI Host to shutdown" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then while ping -qw 10 -c3 "10.10.2.10">/dev/null 2>&1; do sleep 1; done echo -e "${idsCL[Green]}Done${idsCL[Default]}\n" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi MSG="Powering OFF the SAS Enclosure" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then if [ "$(CHECK_HOST 10.10.2.10)" == "false" ]; then run=$(snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.14 i 2 >/dev/null 2>&1) sleep 3s echo -e "${idsCL[Green]}Done${idsCL[Default]}\n" else echo -e "${idsCL[LightRed]}'${PW_iDRACHOST_SHORTNAMES[${idracip}]}' is not offline, not powering down\n" fi else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi echo fi fi elif [ "${1^^}" == "MAINSITE" ]; then if [ ! -f ${PW_TMPFOLDER}/power.main.offsite ]; then touch ${PW_TMPFOLDER}/power.main.offsite if [ "${2}" != "maintenance" ]; then MSG="Disabling CLS in vCenter" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(ssh root@${PW_VCENTERHOST} "sed -i '//{n;s/.*<\/enabled>/False<\/enabled>/}' /etc/vmware-vpx/vpxd.cfg >/dev/null 2>&1" >/dev/null 2>&1) run=$(ssh root@${PW_VCENTERHOST} "service-control --stop vmware-vpxd >/dev/null 2>&1" >/dev/null 2>&1) run=$(ssh root@${PW_VCENTERHOST} "service-control --start vmware-vpxd >/dev/null & 2>&1" >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}\n" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi echo fi for ESXIHOST in "${PW_MAINSITEHOSTS[@]}"; do MSG="Stopping iSCSI VM's on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(${PW_FOLDER}/esxi-scripts/iscsi-all-vm-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo for ESXIHOST in "${PW_MAINSITEHOSTS[@]}"; do MSG="Enabling Maintenance Mode on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(${PW_FOLDER}/esxi-scripts/host-maintenance_mode.ps1 ${ESXIHOST} & >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo for ESXIHOST in "${PW_MAINSITEHOSTS[@]}"; do MSG="Verifying iSCSI VM's stopped on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(${PW_FOLDER}/esxi-scripts/iscsi-all-shutdown-verify.ps1 ${ESXIHOST} >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo for ESXIHOST in "${PW_MAINSITEHOSTS[@]}"; do MSG="Stopping Remaining VM's on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(${PW_FOLDER}/esxi-scripts/vm-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1) run=$(${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo if [ "${2}" != "maintenance" ]; then for ESXIHOST in "${PW_MAINSITEHOSTS[@]}"; do MSG="Wait for VM's to power off, then shutdown '${PW_ESXI_HOST_NAMES[${ESXIHOST}]}'" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then MAINT_MODE_VERIFY_SHUTDOWN ${ESXIHOST} & echo -e "${idsCL[Green]}Continuing in background\n" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo MSG="Waiting for iSCSI-PRI Host to shutdown" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then while ping -qw 10 -c3 "10.10.2.10">/dev/null 2>&1; do sleep 1; done echo -e "${idsCL[Green]}Done${idsCL[Default]}\n" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi MSG="Powering OFF the SAS Enclosure" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then if [ "$(CHECK_HOST 10.10.2.10)" == "false" ]; then run=$(snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.14 i 2 >/dev/null 2>&1) sleep 3s echo -e "${idsCL[Green]}Done${idsCL[Default]}\n" else echo -e "${idsCL[LightRed]}'${PW_iDRACHOST_SHORTNAMES[${idracip}]}' is not offline, not powering down\n" fi else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi echo fi fi elif [ "${1^^}" == "OFFSITE" ]; then if [ ! -f ${PW_TMPFOLDER}/power.offsite.off ]; then touch ${PW_TMPFOLDER}/power.offsite.off if [ "${2}" != "maintenance" ]; then MSG="Disabling CLS in vCenter" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(ssh root@${PW_VCENTERHOST} "sed -i '//{n;s/.*<\/enabled>/False<\/enabled>/}' /etc/vmware-vpx/vpxd.cfg >/dev/null 2>&1" >/dev/null 2>&1) run=$(ssh root@${PW_VCENTERHOST} "service-control --stop vmware-vpxd >/dev/null 2>&1" >/dev/null 2>&1) run=$(ssh root@${PW_VCENTERHOST} "service-control --start vmware-vpxd >/dev/null & 2>&1" >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi echo fi for ESXIHOST in "${PW_OFFSITEHOSTS[@]}"; do MSG="Enabling Maintenance Mode on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(${PW_FOLDER}/esxi-scripts/host-maintenance_mode.ps1 ${ESXIHOST} & >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo for ESXIHOST in "${PW_OFFSITEHOSTS[@]}"; do MSG="Stopping Remaining VM's on: ${PW_ESXI_HOST_NAMES[${ESXIHOST}]}" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(${PW_FOLDER}/esxi-scripts/vm-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo if [ "${2}" != "maintenance" ]; then for ESXIHOST in "${PW_OFFSITEHOSTS[@]}"; do MSG="Wait for VM's to power off, then shutdown '${PW_ESXI_HOST_NAMES[${ESXIHOST}]}'" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then MAINT_MODE_VERIFY_SHUTDOWN ${ESXIHOST} & echo -e "${idsCL[Green]}Continuing in background\n" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo fi fi fi } MAINT_MODE_VERIFY_SHUTDOWN(){ ESXIHOST=${1} MaintMode="" until [ "${MaintMode}" == "Enabled" ]; do sleep 3s MaintMode=$(ssh root@${ESXIHOST} 'esxcli system maintenanceMode get') done ssh root@${ESXIHOST} 'esxcli system shutdown poweroff -d 10 -r "Power-Monitor script initiated system shutdown"' ssh root@${ESXIHOST} 'esxcli system maintenanceMode set -e false -t 0' # if [ "${ESXIHOST}" == "10.10.2.10" ]; then # while ping -qw 10 -c3 "${ESXIHOST}">/dev/null 2>&1; do sleep 1; done # "$(CHECK_HOST ${ESXIHOST})" == "false" ] && snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.14 i 2 # fi } SHUTDOWN_SERVER(){ if [ "${PW_iDRACHOST_SHORTNAMES[${1}]}" != "" ]; then tmp=${PW_iDRACHOST_SHORTNAMES[${1}]} ESXIHOST=${PW_HOST_ADDRESSES[${tmp}]} elif [ "${PW_ESXI_HOST_NAMES[${1}]}" != "" ]; then ESXIHOST=${1} elif [ "${PW_HOST_IDRACS[iDS-vMS-Host${1}]}" != "" ]; then ESXIHOST=${PW_HOST_ADDRESSES[iDS-vMS-Host${1}]} elif [ "${PW_HOST_IDRACS[${1}]}" != "" ]; then tmp=${PW_HOST_IDRACS[${1}]} ESXIHOST=${PW_HOST_ADDRESSES[${tmp}]} else ESXIHOST='' fi if [ "${ESXIHOST}" != "" ]; then host=${PW_ESXI_HOST_NAMES[${ESXIHOST}]} if [ "${2}" == "maintenance" ]; then echo "($(date +'%Y-%m-%d %H:%M:%S')) - Putting ${host} [${ESXIHOST}] into maintenance mode" >> ${PW_LOGFILE} else echo "($(date +'%Y-%m-%d %H:%M:%S')) - Shutting down ${host} [${ESXIHOST}]" >> ${PW_LOGFILE} fi if [ "${ESXIHOST}" == "10.10.2.10" ]; then echo -e "${idsCL[LightYellow]}Since this is the iSCSI-PRI host server, all iSCSI-PRI VM's are being shutdown ... " for ehost in "${PW_MAINSITEHOSTS[@]}"; do MSG="Stopping iSCSI-PRI VM's on: ${PW_ESXI_HOST_NAMES[${ehost}]} [${ehost}]" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then ${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown.ps1 ${ehost} >/dev/null 2>&1 & echo -e "${idsCL[Green]}Commands sent${idsCL[Default]}" sleep 5s else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo [ "${TEST}" != "true" ] && sleep 10s elif [ "${ESXIHOST}" == "10.10.2.17" ]; then echo -e "${idsCL[LightYellow]}Since this is the iSCSI-SYS host server, all iSCSI-SYS VM's are being shutdown ... " for ehost in "${PW_MAINSITEHOSTS[@]}"; do MSG="Stopping iSCSI-SYS VM's on: ${PW_ESXI_HOST_NAMES[${ehost}]} [${ehost}]" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then ${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown.ps1 ${ehost} >/dev/null 2>&1 & echo -e "${idsCL[Green]}Commands sent${idsCL[Default]}" sleep 5s else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi done echo [ "${TEST}" != "true" ] && sleep 10s fi MSG="Enabling maintenance mode & starting iSCSI VM migrations" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then ${PW_FOLDER}/esxi-scripts/host-maintenance_mode.ps1 ${PW_VCENTER_HOST_NAMES[${ESXIHOST}]} >/dev/null 2>&1 & sleep 25s echo -e "${idsCL[Green]}Done${idsCL[Default]}\n" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi MSG="Shutting down remaining VM's" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(${PW_FOLDER}/esxi-scripts/vm-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1) if [ "${ESXIHOST}" == "10.10.2.10" ] || [ "${ESXIHOST}" == "10.10.2.17" ]; then if [ "${ESXIHOST}" == "10.10.2.10" ]; then run=$(${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown-verify.ps1 ${ESXIHOST} >/dev/null 2>&1) elif [ "${ESXIHOST}" == "10.10.2.17" ]; then run=$(${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown-verify.ps1 ${ESXIHOST} >/dev/null 2>&1) fi run=$(${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1) fi run=$(${PW_FOLDER}/esxi-scripts/cls-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}\n" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi if [ "${2}" != "maintenance" ]; then MSG="Waiting for VM's to power off or migrate" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then MAINT_MODE_VERIFY_SHUTDOWN ${ESXIHOST} & echo -e "${idsCL[Green]}Continuing in background\n" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi if [ "${ESXIHOST}" == "10.10.2.10" ]; then MSG="Waiting for Host ${host} [${ESXIHOST}] to shutdown" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then while ping -qw 10 -c3 "${ESXIHOST}">/dev/null 2>&1; do sleep 1; done echo -e "${idsCL[Green]}Done${idsCL[Default]}\n" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi MSG="Powering off SAS Enclosure" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ] && [ "$(CHECK_HOST 10.10.2.10)" == "false" ]; then run=$(snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.14 i 2) sleep 3s echo -e "${idsCL[Green]}Done${idsCL[Default]}\n" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi else echo -e "\n${idsCL[LightCyan]}The host ${host} [${ESXIHOST}] will be shutdown momentarily ... \n" fi else echo -e "\n${idsCL[LightCyan]}The host ${host} [${ESXIHOST}] will be in maintenance mode momentarily ... \n" fi else echo -e "${idsCL[LightRed]}Host cannot be found for '${1}'${idsCL[Default]}" fi echo } HOSTMGMT(){ echo -e "\n${idsCL[Yellow]}Host Controls${idsCL[Default]}" DIVIDER . yellow 75 if [ "${1}" != "-h" ]; then HOST=${1}; MN=0 if [ "${PW_iDRACHOST_SHORTNAMES[${HOST}]}" != "" ]; then tmp=${PW_iDRACHOST_SHORTNAMES[${HOST}]} ESXI_HOST=${PW_HOST_ADDRESSES[${tmp}]} elif [ "${PW_ESXI_HOST_NAMES[${HOST}]}" != "" ]; then ESXI_HOST=${HOST} elif [ "${PW_HOST_ADDRESSES[iDS-vMS-Host${HOST}]}" != "" ]; then ESXI_HOST=${PW_HOST_ADDRESSES[iDS-vMS-Host${HOST}]} elif ([ "${HOST::1}" == "o" ] || [ "${HOST::1}" == "O" ]) && [ "${PW_HOST_ADDRESSES[OFF-vMS-Host${HOST: -1}]}" != "" ]; then ESXI_HOST=${PW_HOST_ADDRESSES[OFF-vMS-Host${HOST: -1}]} elif [ "${PW_HOST_ADDRESSES[${HOST}]}" != "" ]; then ESXI_HOST=${PW_HOST_ADDRESSES[${HOST}]} elif [ "${1^^}" == "ALL" ] || [ "${1^^}" == "MAINSITE" ] || [ "${1^^}" == "OFFSITE" ] || [ "${1^^}" == "MAIN" ] || [ "${1^^}" == "SYS" ]; then ESXI_HOST=${HOST^^} MN=1 else ESXI_HOST='' fi [ "${ESXI_HOST}" == "" ] && echo -e "Invalid host\n" && exit 1 if [ ${MN} -eq 1 ]; then [ "${ESXI_HOST}" == "ALL" ] && hostname="All Host Servers" || hostname="All ${ESXI_HOST} Host Servers" else tmp=${PW_ESXI_HOST_NAMES[${ESXI_HOST}]} idracip=${PW_HOST_IDRACS[${tmp}]} hostname=${PW_iDRACHOST_SHORTNAMES[${idracip}]} fi if [ "${PW_ESXI_HOST_NAMES[${ESXI_HOST}]}" != "" ]; then tmp=${PW_ESXI_HOST_NAMES[${ESXI_HOST}]} idracip=${PW_HOST_IDRACS[${tmp}]} hostname=${PW_iDRACHOST_SHORTNAMES[${idracip}]} fi fi while [ $# -gt 0 ]; do case "$1" in -p|-power) POWER=${2}; MODE="power";; -e|-esxi) ESXI=${2}; MODE="esxi";; -h) echo -e "Usage: ${idsCL[Yellow]}pw host {host} {flags}${idsCL[Default]} {" width=35 printf "%-${width}s- %s\n" " {host}" "(*required, can either be esxiIP,idracIP or Host#)" printf "%-${width}s- %s\n" " -p|-power {on / off}" "Controls Host Power" printf "%-${width}s- %s\n" " -e|-esxi {off / mm}" "Shuts down ESXi or puts into maintenance mode" echo -e "}\n" exit 0 ;; esac shift 1 done c=0; spcA=''; spc1=`expr 21 - ${#hostname} - 1`; until [ ${c} = ${spc1} ]; do spcA="${spcA} "; c=`expr ${c} + 1`; done echo -en "${idsCL[LightCyan]} Host: ${idsCL[Green]}${hostname}${spcA}" if [ "${HOST^^}" == "ALL" ] || [ "${HOST^^}" == "MAINSITE" ] || [ "${HOST^^}" == "OFFSITE" ] || [ "${HOST^^}" == "MAIN" ] || [ "${HOST^^}" == "SYS" ]; then echo -e "" else c=0; spcB=''; spc1=`expr 18 - ${#ESXI_HOST} - 1`; until [ ${c} = ${spc1} ]; do spcB="${spcB} "; c=`expr ${c} + 1`; done echo -en "${idsCL[LightCyan]}Host IP: ${idsCL[Green]}${ESXI_HOST}${spcB}" echo -e "${idsCL[LightCyan]}iDrac IP: ${idsCL[Green]}${idracip}${idsCL[Default]}" fi DIVIDER . yellow 75 if [ "${HOST^^}" == "ALL" ] || [ "${HOST^^}" == "MAINSITE" ] || [ "${HOST^^}" == "OFFSITE" ] || [ "${HOST^^}" == "MAIN" ] || [ "${HOST^^}" == "SYS" ]; then var=PW_${HOST^^}HOSTS[@]; v=1 for vhost in "${!var}"; do echo -e " ${v})${idsCL[LightCyan]} ${PW_ESXI_HOST_NAMES[${vhost}]} [${vhost}]${idsCL[Default]}" ((v++)) done DIVIDER . yellow 75 fi echo ([ "${HOST}" == "" ] || ([ "${POWER}" == "" ] && [ "${ESXI}" == "" ])) && echo -e "Invalid command arguments\n" && exit 1 if [ "${MODE}" == "esxi" ]; then if [ "${HOST^^}" == "ALL" ] || [ "${HOST^^}" == "MAINSITE" ] || [ "${HOST^^}" == "OFFSITE" ] || [ "${HOST^^}" == "MAIN" ] || [ "${HOST^^}" == "SYS" ]; then if [ "${ESXI}" == "maint" ] || [ "${ESXI}" == "maintenance" ] || [ "${ESXI}" == "mm" ]; then echo -e "${idsCL[LightGreen]}PUTTING '${ESXI_HOST}' HOSTS INTO MAINTENANCE MODE${idsCL[Default]}\n" # SHUTDOWN_SERVERS ${ESXI_HOST,,} maintenance SHUTDOWN_SERVERS2 ${ESXI_HOST,,} maintenance else echo -e "${idsCL[LightGreen]}SHUTTING DOWN '${ESXI_HOST}' HOSTS${idsCL[Default]}\n" # SHUTDOWN_SERVERS ${ESXI_HOST,,} SHUTDOWN_SERVERS2 ${ESXI_HOST,,} fi else if [ "${ESXI}" == "maint" ] || [ "${ESXI}" == "maintenance" ] || [ "${ESXI}" == "mm" ]; then echo -e "${idsCL[LightGreen]}PUTTING HOST INTO MAINTENANCE MODE${idsCL[Default]}\n" # SHUTDOWN_SERVER ${HOST} maintenance SHUTDOWN_SERVER2 ${HOST} maintenance else echo -e "${idsCL[LightGreen]}SHUTTING DOWN HOST${idsCL[Default]}\n" # SHUTDOWN_SERVER ${HOST} SHUTDOWN_SERVER2 ${HOST} fi fi elif [ "${MODE}" == "power" ]; then if [ "${HOST^^}" == "ALL" ] || [ "${HOST^^}" == "MAINSITE" ] || [ "${HOST^^}" == "OFFSITE" ] || [ "${HOST^^}" == "MAIN" ] || [ "${HOST^^}" == "SYS" ]; then var=PW_${HOST^^}HOSTS[@]; v=1 for vhost in "${!var}"; do HOSTPOWER ${vhost} ${POWER} done else HOSTPOWER ${HOST} ${POWER} fi fi echo } ISCSIVMSHUTDOWN(){ for ESXIHOST in "${PW_MAINSITEHOSTS[@]}"; do echo -en "${idsCL[LightCyan]}Shutting down any VM's on '${ESXIHOST}' that are running on an iSCSI-PRI drive ... " ${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1 & echo -e "${idsCL[Green]}Commands sent${idsCL[Default]}" echo done echo -e "${idsCL[LightCyan]}Please wait a few minutes while all iSCSI guests are shutdown ..." echo } ISCSISYSVMSHUTDOWN(){ for ESXIHOST in "${PW_MAINSITEHOSTS[@]}"; do echo -en "${idsCL[LightCyan]}Shutting down any VM's on '${ESXIHOST}' that are running on an iSCSI-SYS drive ... " ${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown.ps1 ${ESXIHOST} >/dev/null 2>&1 & echo -e "${idsCL[Green]}Commands sent${idsCL[Default]}" echo done echo -e "${idsCL[LightCyan]}Please wait a few minutes while all iSCSI guests are shutdown ..." echo } HOSTPOWER(){ if [ "${PW_iDRACHOST_SHORTNAMES[${1}]}" != "" ]; then idracip=${1} elif [ "${PW_ESXI_HOST_NAMES[${1}]}" != "" ]; then tmp=${PW_ESXI_HOST_NAMES[${1}]} idracip=${PW_HOST_IDRACS[${tmp}]} elif [ "${PW_HOST_IDRACS[iDS-vMS-Host${1}]}" != "" ]; then idracip=${PW_HOST_IDRACS[iDS-vMS-Host${1}]} elif [ "${PW_HOST_IDRACS[${1}]}" != "" ]; then idracip=${PW_HOST_IDRACS[${1}]} else idracip='' fi echo -e "\n${idsCL[Yellow]}POWERING ${2^^} '${PW_iDRACHOST_SHORTNAMES[${idracip}]}'" DIVIDER . yellow 75 if [ "${idracip}" != "" ]; then # host=${PW_iDRACHOST_SHORTNAMES[${idracip}]} # c=0; spcA=''; spc1=`expr 21 - ${#host} - 1`; until [ ${c} = ${spc1} ]; do spcA="${spcA} "; c=`expr ${c} + 1`; done # c=0; spcB=''; spc1=`expr 18 - ${#PW_HOST_ADDRESSES[${host}]} - 1`; until [ ${c} = ${spc1} ]; do spcB="${spcB} "; c=`expr ${c} + 1`; done # echo -en "${idsCL[LightCyan]} Host: ${idsCL[Green]}${host}${spcA}" # echo -en "${idsCL[LightCyan]}Host IP: ${idsCL[Green]}${PW_HOST_ADDRESSES[${host}]}${spcB}" # echo -e "${idsCL[LightCyan]}iDrac IP: ${idsCL[Green]}${idracip}${idsCL[Default]}" # DIVIDER . yellow 75 # echo if [ "${2^^}" == "ON" ] || [ "${2^^}" == "OFF" ] || [ "${2^^}" == "STATUS" ]; then if [ "${idracip}" == "10.10.2.20" ] && [ "${2^^}" == "ON" ]; then MSG="Powering ON the SAS Enclosure" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "\n${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then run=$(snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.14 i 1 >/dev/null 2>&1) sleep 3s echo -e "${idsCL[Green]}Done${idsCL[Default]}\n" else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi fi if [ "${TEST}" != "true" ]; then echo -e "${idsCL[Green]}" ipmitool -I lanplus -H ${idracip} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" chassis power ${2,,} else echo -e "\n${idsCL[Yellow]}(TEST MODE)" fi echo -e "${idsCL[Default]}" if [ "${idracip}" == "10.10.2.20" ] && [ "${2^^}" == "OFF" ]; then MSG="Powering OFF the SAS Enclosure" c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: " if [ "${TEST}" != "true" ]; then if [ "$(CHECK_HOST 10.10.2.10)" == "false" ]; then run=$(snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.14 i 2 >/dev/null 2>&1) sleep 3s echo -e "${idsCL[Green]}Done${idsCL[Default]}\n" else echo -e "${idsCL[LightRed]}'${PW_iDRACHOST_SHORTNAMES[${idracip}]}' is not offline, not powering down\n" fi else echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}" fi fi else echo -e "${idsCL[LightRed]}'${2^^}' command is not recognized${idsCL[Default]}" fi else echo -e "${idsCL[LightRed]}Host cannot be found for '${1}'${idsCL[Default]}" fi echo -e "${idsCL[Default]}\n" } PDUCONTROL(){ function exitspacing { echo -e "\n\033[K\n\033[K" exit 0 } trap exitspacing EXIT while [ $# -gt 0 ]; do case "$1" in -port) PORT_SEL=${2};; esac shift 1 done echo DIVIDER . yellow 75 echo -e "${idsCL[Yellow]}APC-PDU Power Control" DIVIDER true yellow 75 [ "${PORT_SEL}" != "" ] && PORTSEL=${PORT_SEL} if [ "${PORTSEL}" == "" ]; then PORT_DESC=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.2 -O vq 2> /dev/null | sed -e 's/"//g') IFS=$'\n' read -rd '' -a PORT_DESC <<<"${PORT_DESC}" unset IFS p=1 for port in "${PORT_DESC[@]}"; do portpower=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.${p} -O vq 2> /dev/null | sed -e 's/"//g') [ ${portpower} -eq 1 ] && portpower_disp="${idsCL[Green]}ON" || portpower_disp="${idsCL[LightRed]}OFF" [ ${p} -lt 10 ] && pp=" ${p}" || pp=${p} c=0; spc=''; spc1=`expr 28 - ${#port}`; until [ ${c} = ${spc1} ]; do spc="${spc} "; c=`expr ${c} + 1`; done echo -e "${pp}) ${idsCL[LightCyan]}${port}${spc}${idsCL[Default]}: ${portpower_disp}${idsCL[Default]}" ((p++)) done echo -e "" echo -e "" echo -e "(${idsCL[Yellow]}E${idsCL[Default]})xit" echo -e "" echo -e "\033[5A" until [ "${PORTSEL}" != "" ]; do echo -en "\n${idsCL[LightCyan]}Enter the port number to control: ${idsCL[Default]}" read PORTSEL echo done fi [ "${PORTSEL^^}" == "E" ] && exit 0 portsel_power=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.${PORTSEL} -O vq 2> /dev/null | sed -e 's/"//g') [ ${portsel_power} -eq 1 ] && portsel_power_disp="${idsCL[Green]}ON" || portsel_power_disp="${idsCL[LightRed]}OFF" [ ${portsel_power} -eq 2 ] && portsel_change_power_disp="${idsCL[Green]}ON" || portsel_change_power_disp="${idsCL[LightRed]}OFF" if [ "${PORT_SEL}" != "" ]; then portdesc=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.2.${PORT_SEL} -O vq 2> /dev/null | sed -e 's/"//g') echo -e "${idsCL[Yellow]}Port ${PORT_SEL}${idsCL[Default]}) ${idsCL[LightCyan]}${portdesc} ${idsCL[Default]}: ${portsel_power_disp}${idsCL[Default]}\n" fi echo -en "${idsCL[LightCyan]}Are you sure you wish to turn ${portsel_change_power_disp}${idsCL[LightCyan]} port ${idsCL[Yellow]}${PORTSEL}${idsCL[Default]} (y/N): " read -n 1 portchange_confirm case "${portchange_confirm}" in [Yy]) [ ${portsel_power} -eq 1 ] && portsel_change=2 || portsel_change=1 echo -en "\n\n${idsCL[LightCyan]}Turning ${portsel_change_power_disp}${idsCL[LightCyan]} port ${idsCL[Yellow]}${PORTSEL}${idsCL[Default]} ... " run=$(snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.${PORTSEL} i ${portsel_change} >/dev/null 2>&1) echo -e "${idsCL[Green]}Done${idsCL[Default]}" echo if [ "${PORT_SEL}" == "" ]; then sleep 1s unset PORTSEL PDUCONTROL exit 0 fi ;; *) if [ "${PORT_SEL}" == "" ]; then unset PORTSEL PDUCONTROL exit 0 fi ;; esac } LOGROTATE(){ STOPALL_SERVICES lm=`expr $(date +'%m') - 1` if [ ${lm} = 0 ]; then lm=12 ly=`expr $(date +'%Y') - 1` else ly=$(date +'%Y') fi [ ${lm} -lt 10 ] && lm="0${lm}" ARCHIVEFOLDER=${PW_LOGARCHIVE}/${ly}-${lm} mkdir -p ${ARCHIVEFOLDER} sleep 5s mv ${PW_LOGFOLDER}/log* ${ARCHIVEFOLDER}/ 2> /dev/null mv ${PW_LOGFOLDER}/service.* ${ARCHIVEFOLDER}/ 2> /dev/null # source ${PW_FOLDER}/defaults.inc STARTALL_SERVICES backupstokeep=(`ls -d ${PW_LOGARCHIVE}/* 2> /dev/null | sort | tail -12`) for folder in $(ls -d ${PW_LOGARCHIVE}/* | sort -r); do keep=0 for filetokeep in ${backupstokeep[@]}; do if [ "${folder}" == "${filetokeep}" ]; then keep=1; break fi done; [ ${keep} == 0 ] && rm -Rf ${folder} done } GET_SNAPSHOTS(){ echo for SENSOR in ${PW_SENSOR_ORD[@]}; do if [ "${PW_HOST_ADDRESSES[${SENSOR}]}" != "" ]; then ESXIHOST=${PW_HOST_ADDRESSES[${SENSOR}]} echo -e "${idsCL[LightGreen]}${PW_ESXI_HOST_NAMES[${ESXIHOST}]} [${ESXIHOST}] " DIVIDER . lightGreen 70 echo -en "${idsCL[LighGreen]}Looking for snapshots...${idsCL[Default]}" snapshots=`${PW_FOLDER}/esxi-scripts/get-snapshots.ps1 ${ESXIHOST}` if [ "${snapshots}" != "" ]; then echo -en "\033[2K\033[1A" echo -e "${snapshots}" # for snapshot in $(echo ${snapshots} | jq -r '.[] | @base64'); do # vm=`echo ${snapshot} | base64 --decode | jq -r '.VM'` # name=`echo ${snapshot} | base64 --decode | jq -r '.Name'` # created=`echo ${snapshot} | base64 --decode | jq -r '.Created'` # size=`echo ${snapshot} | base64 --decode | jq -r '.SizeGB'` # echo "$vm - $name - ${c}reated - $size" # done else echo -e "\033[2K\e[0K\r No snapshots found" fi DIVIDER true lightGreen 70 fi done } CONFSYNC(){ rsync -az --timeout=3 ${PW_FOLDER}/settings.conf root@10.2.1.1:${PW_FOLDER}/ & >/dev/null 2>&1 } TEST(){ start=`date +%s` temptotal=0 daysback=${1} logsfound=0; while IFS=$'\t' read date sensorid temp hum ;do # echo date:$date sensorid:$sensorid temp:$temp hum:$hum temptotal=$(bc <<< "scale=2; ${temptotal}+${temp}") # echo "- ${temptotal} + ${temp}" ((logsfound++)) done < <(${mysql_conn} -se "USE servermonitor; SELECT date,sensorid,temp,hum from sensor_data WHERE sensorid=2 AND date BETWEEN DATE_SUB(DATE(NOW()), INTERVAL ${daysback} DAY) AND NOW() ORDER BY id DESC;") average=$(bc <<< "scale=2; ${temptotal}/${logsfound}") echo "Logs found: ${logsfound}" echo "Average: ${average}'F" echo # QRY="INSERT INTO inv_jsonstats (\`date\`, \`data\`) VALUES ('$(date +'%Y-%m-%d %H:%M:%S')','${INVSTATSINFO}')" # ${mysql_conn} -e "USE servermonitor; ${QRY}" end=`date +%s` runtime=$((end-start)) echo "runtime: ${runtime}" echo } ######################################################### if [[ "${1}" != *"_service" ]] && [[ "${noheader}" != *" ${1} "* ]] && [[ "${noheader}" != *" ${2} "* ]]; then echo DIVIDER . lightGreen 70 msg="| PowerWall Management ${idsCL[Default]} ${idsCL[DarkGray]}(ver-${VERS})" c=0; spc=''; spc1=`expr 81 - ${#msg}`; until [ ${c} = ${spc1} ]; do spc="${spc} "; c=`expr ${c} + 1`; done echo -e "${idsCL[LightGreen]}${msg}${spc}${idsCL[LightGreen]}|${idsCL[Default]}" DIVIDER . lightGreen 70 fi # if [ ${PW_ACTION-x} ]; then case ${PW_ACTION} in services) [ "${2}" == "stop" ] && STOPALL_SERVICES [ "${2}" == "start" ] && STARTALL_SERVICES [ "${2}" == "restart" ] && RESTARTALL_SERVICES [ "${2}" == "status" ] && CHECK_SERVICES ;; dailytemp) start=`date +%s` DAILYTEMP # SENDNOTICE "Daily Temp Readings" "$(DAILYTEMP)" end=`date +%s`; runtime=$((end-start)) echo -e "\nruntime: ${runtime}\n" ;; checktemp) CHECKTEMP ${2} ${3} ${4} ${5} ${6} ${7} ${8} ${9} ${10};; checkpower) CHECKPOWER ${2} ${3} ${4} ${5} ${6} ${7} ${8} ${9} ${10};; check) ([ "${2}" == "" ] || ([ "${2}" != "power" ] && [ "${2}" != "temp" ])) && checkrun="-help" || checkrun=${2} case ${checkrun} in power) CHECKPOWER ${3} ${4} ${5} ${6} ${7} ${8} ${9} ${10};; temp) CHECKTEMP ${3} ${4} ${5} ${6} ${7} ${8} ${9} ${10};; -h|-help) echo -e "\nUsage: ${idsCL[Yellow]}[powerwall or pw] ${idsCL[LightYellow]}check ${idsCL[LightCyan]}{type} {flags} ${idsCL[Default]} {\n" width=35 printf "%-${width}s- %s\n" " {type}" "{power or temp} To check either power or temperatures" echo -e "\n ${idsCL[LightCyan]}power${idsCL[Default]} {flag} options" printf "%-${width}s- %s\n" " -a|-avg {#days}" "Show average values for X number of days" printf "%-${width}s- %s\n" " -m|-mainsite" "Narrow to Mainsite Equipment" printf "%-${width}s- %s\n" " -o|-offsite" "Narrow to Offsite Equipment" printf "%-${width}s- %s\n" " -p|-power" "Narrow to Power Equipment" printf "%-${width}s- %s\n" " -e|-esxi" "Narrow to ESXi Hosts" echo -e "\n ${idsCL[LightCyan]}temp${idsCL[Default]} {flag} options" printf "%-${width}s- %s\n" " -a|-avg {#days}" "Show average values for X number of days" printf "%-${width}s- %s\n" " -S|-sensors" "Narrow to Sensors Only" printf "%-${width}s- %s\n" " -e|-esxi" "Narrow to ESXi Hosts Only" printf "%-${width}s- %s\n" " -s|-search" "Narrow to search of sensor name" echo -e "}\n" exit 0 ;; esac ;; test) CHECKTEMP ${2} ${3};; iscsi-vm-shutdown) [ "${2^^}" == "SYS" ] && ISCSISYSVMSHUTDOWN || ISCSIVMSHUTDOWN ;; shutdownhost) SHUTDOWN_SERVER ${2} ${3};; shutdowntest) SHUTDOWN_SERVER2 ${2} ${3};; shutdown_servers) SHUTDOWN_SERVERS ${2} ${3};; hostpower) HOSTPOWER ${2} ${3};; host) HOSTMGMT ${2} ${3} ${4} ${5} ${6} ${7};; pdu) PDUCONTROL ${2} ${3};; get-snapshots) GET_SNAPSHOTS;; service) if [ "${2}" = "all" ]; then if [ "${3}" == "stop" ]; then STOPALL_SERVICES elif [ "${3}" == "start" ]; then STARTALL_SERVICES elif [ "${3}" == "restart" ]; then RESTARTALL_SERVICES elif [ "${3}" == "status" ]; then CHECK_SERVICES fi else if [ "${3}" = "start" ] || [ "${3}" = "" ]; then echo "start: ${1}" if [ "${2}" = "temp" ]; then # SENDNOTICE "Temp Monitor Startup" "$(DAILYTEMP)" & CHECKTEMP_SERVICE elif [ "${2}" = "power" ]; then CHECKPOWER_SERVICE elif [ "${2}" = "powerlogger" ]; then POWERLOGGER_SERVICE fi elif [ "${3}" = "stop" ]; then if [ "${2}" = "temp" ]; then STOP_SERVICE temp for SENSOR in ${!PW_SENSOR_ID[@]}; do logtemp=${PW_LOGFOLDER}/log-temp-${SENSOR} echo "(`date +'%Y-%m-%d %H:%M:%S'`) - ${SENSOR} - Service Stopped" >> ${logtemp} done elif [ "${2}" = "power" ]; then STOP_SERVICE power echo "(`date +'%Y-%m-%d %H:%M:%S'`) Service Stopped" >> ${PW_LOGPOWER} elif [ "${2}" = "powerlogger" ]; then STOP_SERVICE powerlogger fi elif [ "${3}" = "restart" ]; then SERVICE_MNG ${2} stop sleep 2s SERVICE_MNG ${2} start elif [ "${3}" = "status" ]; then srvc=${PW_POWERWALL_SERVICES[${2}]} c=0; spc=''; spc1=`expr 25 - ${#srvc}`; until [ ${c} = ${spc1} ]; do spc="${spc} "; c=`expr ${c} + 1`; done echo -e "${idsCL[LightCyan]}${srvc}${spc}: " [ "$(systemctl is-active ${srvc})" == "active" ] && echo -en "${idsCL[Green]}Running" || echo -en "${idsCL[Yellow]}Not Running" echo -e "${idsCL[Default]}" echo fi fi ;; logrotate) LOGROTATE;; confsync) CONFSYNC;; status) CHECKPOWER -p ${2} ${3} CHECKTEMP -S ${2} ${3} CHECK_SERVICES ;; average) AVERAGETEMP ${2} ${3} ${4};; oldhelp) echo -e "${idsCL[White]} Usage: ${idsCL[LightYellow]}[powerwall or pw]${idsCL[LightCyan]} {option}" echo echo -e " ${idsCL[LightCyan]}status ${idsCL[Default]}--> PowerWall Status Information" echo echo -e " ${idsCL[LightCyan]}check${idsCL[Yellow]} {type} {opts} ${idsCL[Default]}--> Check Sensors" echo -e " ${idsCL[Yellow]} type = { power / temp }" echo -e " ${idsCL[Yellow]} opts =" echo -e " ${idsCL[Yellow]} power { all / mainsite / offsite } ${idsCL[Default]}--> Defaults to All" echo -e " ${idsCL[Yellow]} temp { avg for # of days to show } ${idsCL[Default]}--> Defaults to not showing averages" echo echo -e " ${idsCL[LightCyan]}host${idsCL[Yellow]} {host} {flags} ${idsCL[Default]}--> Host Power/ESXi Control" echo -e " ${idsCL[Yellow]} host = individual {esxi-ip}, {idrac-ip}, {hostname} or {host-number;0-9}" echo -e " ${idsCL[Yellow]} host = groups { all / mainsite / offsite / main / sys }" echo -e " ${idsCL[Yellow]} flags =" echo -e " ${idsCL[Yellow]} -p|-power { on / off } ${idsCL[Default]}--> Controls Host Power" echo -e " ${idsCL[Yellow]} -e|-esxi { off / mm } ${idsCL[Default]}--> Shuts down ESXi or puts into maintenance mode" echo # echo -e " ${idsCL[Yellow]}shutdownhost {host} ${idsCL[Default]}--> Shutdown ESXI host and its VMs" # echo -e " ${idsCL[LightYellow]} host = {esxi-ip}, {idrac-ip}, {hostname} or {host-number;0-9}" # echo # echo -e " ${idsCL[LightCyan]}shutdown_servers${idsCL[Yellow]} {type} ${idsCL[Default]}--> Shutdown selection of servers" # echo -e " ${idsCL[Yellow]} type = { main / sys / all }" # echo echo -e " ${idsCL[LightCyan]}iscsi-vm-shutdown${idsCL[Yellow]} {type} ${idsCL[Default]}--> Shutdown VM's running on iSCSI-(PRI or SYS) Datastore(s)" echo -e " ${idsCL[Yellow]} type = { sys / main }" echo -e " ${idsCL[Yellow]} sys='iSCSI-SYS' / main='iSCSI-PRI' ${idsCL[Default]}--> Defaults to main (iSCSI-PRI)" echo # echo -e " ${idsCL[Yellow]}hostpower {host} {on/off} ${idsCL[Default]}--> Control host chassis power" # echo -e " ${idsCL[LightYellow]} host = {esxi-ip}, {idrac-ip}, {hostname} or {host-number;0-9}" # echo echo -e " ${idsCL[LightCyan]}service${idsCL[Yellow]} {srvc} {cmd} ${idsCL[Default]}--> Manage an individual monitor service" echo -e " ${idsCL[Yellow]} srvc = { all / temp / power / powerlogger }" echo -e " ${idsCL[Yellow]} cmd = { start / stop / restart / status }" echo echo -e " ${idsCL[LightCyan]}update ${idsCL[Default]}--> Check for and install new PowerWall Script updates" echo ;; *) echo -e "\n${idsCL[Yellow]}Commands followed by '-h' will show specific command help. {work-in-progress}${idsCL[Default]}" echo echo -e "Usage: ${idsCL[LightCyan]}[powerwall or pw] ${idsCL[Yellow]}{COMMAND} ${idsCL[LightYellow]}{FLAGS}${idsCL[Default]} {" echo echo -e " ${idsCL[Yellow]}status${idsCL[Default]} - PowerWall Status Information" echo -e " ${idsCL[Yellow]}check${idsCL[Default]} - Check Power or Temperature Sensors" echo echo -e " ${idsCL[Yellow]}host${idsCL[Default]} - Host Power/ESXi Control" echo -e " ${idsCL[Yellow]}iscsi-vm-shutdown${idsCL[Default]} - Shutdown VM's running on iSCSI-(PRI or SYS) Datastore(s)" echo echo -e " ${idsCL[Yellow]}service${idsCL[Default]} - Manage an individual monitor service across multiple nodes" echo echo -e " ${idsCL[Yellow]}update${idsCL[Default]} - Check for and install new PowerWall Script updates" echo echo -e "}" echo echo exit 0 ;; esac # fi exit 0