Update powerwall.sh

This commit is contained in:
2023-12-10 12:56:37 -06:00
parent 399e32fed6
commit 0391525098

View File

@@ -1263,7 +1263,7 @@ SHUTDOWN_SERVERS(){
if [ ! -f ${PW_FOLDER}/shutdown.main ]; then
touch ${PW_FOLDER}/shutdown.main
if [ "${2}" == "TEMP" ]; then
if [ "${2}" == "TEMP" ] && [ "${2}" != "maintenance" ]; then
MSG="Disabling CLS in vCenter"
c=0; MSG_SPC=''; spc1=`expr ${hc_cw} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: "
@@ -1326,42 +1326,44 @@ SHUTDOWN_SERVERS(){
fi
done
echo
for ESXIHOST in "${PW_MAINHOSTS[@]}"; do
MSG="Wait for VM's to power off, then shutdown '${PW_ESXI_HOST_NAMES[${ESXIHOST}]}'"
if [ "${2}" == "maintenance" ]; then
for ESXIHOST in "${PW_MAINHOSTS[@]}"; do
MSG="Wait for VM's to power off, then shutdown '${PW_ESXI_HOST_NAMES[${ESXIHOST}]}'"
c=0; MSG_SPC=''; spc1=`expr ${hc_cw} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: "
if [ "${TEST}" != "true" ]; then
MAINT_MODE_VERIFY_SHUTDOWN ${ESXIHOST} &
echo -e "${idsCL[Green]}Continuing in background\n"
else
echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}"
fi
done
echo
MSG="Waiting for iSCSI-PRI Host to shutdown"
c=0; MSG_SPC=''; spc1=`expr ${hc_cw} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: "
if [ "${TEST}" != "true" ]; then
MAINT_MODE_VERIFY_SHUTDOWN ${ESXIHOST} &
echo -e "${idsCL[Green]}Continuing in background\n"
while ping -qw 10 -c3 "10.10.2.10">/dev/null 2>&1; do sleep 1; done
echo -e "${idsCL[Green]}Done${idsCL[Default]}\n"
else
echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}"
fi
done
echo
MSG="Waiting for iSCSI-PRI Host to shutdown"
c=0; MSG_SPC=''; spc1=`expr ${hc_cw} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: "
if [ "${TEST}" != "true" ]; then
while ping -qw 10 -c3 "10.10.2.10">/dev/null 2>&1; do sleep 1; done
echo -e "${idsCL[Green]}Done${idsCL[Default]}\n"
else
echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}"
fi
MSG="Powering OFF the SAS Enclosure"
c=0; MSG_SPC=''; spc1=`expr ${hc_cw} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: "
if [ "${TEST}" != "true" ]; then
if [ "$(CHECK_HOST 10.10.2.10)" == "false" ]; then
run=$(snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.14 i 2 >/dev/null 2>&1)
sleep 3s
echo -e "${idsCL[Green]}Done${idsCL[Default]}\n"
MSG="Powering OFF the SAS Enclosure"
c=0; MSG_SPC=''; spc1=`expr ${hc_cw} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: "
if [ "${TEST}" != "true" ]; then
if [ "$(CHECK_HOST 10.10.2.10)" == "false" ]; then
run=$(snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.14 i 2 >/dev/null 2>&1)
sleep 3s
echo -e "${idsCL[Green]}Done${idsCL[Default]}\n"
else
echo -e "${idsCL[LightRed]}'${PW_iDRACHOST_SHORTNAMES[${idracip}]}' is not offline, not powering down\n"
fi
else
echo -e "${idsCL[LightRed]}'${PW_iDRACHOST_SHORTNAMES[${idracip}]}' is not offline, not powering down\n"
echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}"
fi
else
echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}"
echo
fi
echo
fi
elif [ "${1^^}" == "SYS" ]; then