Update power.inc.sh

This commit is contained in:
2023-12-30 16:12:12 -06:00
parent 8e77cc337f
commit 061a506ac9

View File

@@ -22,6 +22,7 @@ GET_OFFSITEHOST_FANSPEED(){
CHECKPOWER(){
start=`date +%s`
rm -f ${PW_TMPFOLDER}/*.hostpower*
REPORT=0
while [ $# -gt 0 ]; do
case "$1" in
-a|-avg) avgdays=${2};;
@@ -30,6 +31,7 @@ CHECKPOWER(){
-e|-esxi) PTYPE=esxi;;
-p|-power) PTYPE=power;;
-r|-report)
REPORT=1
unset idsCL idsBG idsST
idsCL=('')
idsBG=('')
@@ -48,7 +50,7 @@ CHECKPOWER(){
echo -e "${idsCL[Yellow]}Mainsite Power Information ${idsCL[LightYellow]}${avgdayshdr}"
DIVIDER . yellow 75
echo -en "${idsCL[Yellow]}Pulling data from 'Powerwall' ... "
[ ${REPORT} -eq 0 ] && echo -en "${idsCL[Yellow]}Pulling data from 'Powerwall' ... "
INVSTATSINFO=$(curl -s "http://${PW_INVERTER_IP}/stats.json")
if [ "${INVSTATSINFO}" != "" ]; then
@@ -83,7 +85,7 @@ CHECKPOWER(){
fi
fi
echo -en "\r\033[K"
[ ${REPORT} -eq 0 ] && echo -en "\r\033[K"
echo -e "${idsCL[White]}Inverter State ${idsCL[Default]}: ${INV_STATE_disp}"
echo -e "${idsCL[White]}Inverter Mode ${idsCL[Default]}: ${INV_MODE_disp}"
echo -e "${idsCL[White]}Inverter Alarms ${idsCL[Default]}: ${INV_ALARM_disp}"
@@ -104,7 +106,7 @@ CHECKPOWER(){
# echo
DIVIDER . lightCyan 75
echo -en "${idsCL[Yellow]}Pulling data from 'ServerRoom' ... "
[ ${REPORT} -eq 0 ] && echo -en "${idsCL[Yellow]}Pulling data from 'ServerRoom' ... "
# if [ "$(CHECK_HOST ${PW_UPS_IP})" != "false" ]; then
SVRRM_VOLTIN=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_UPS_IP} iso.3.6.1.4.1.850.1.1.3.1.3.2.2.1.3.1.1 | sed 's/.*: //')
@@ -133,7 +135,7 @@ CHECKPOWER(){
VOLT_DROP=`echo "scale=1; ${OUTPUTV2}-${SVRRM_VOLTIN}" | bc`
fi
echo -en "\r\033[K"
[ ${REPORT} -eq 0 ] && echo -en "\r\033[K"
echo -e "${idsCL[White]}ServerRack Amps ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${APCPDU_AMP}`'amps${idsCL[Default]}"
MSG="${idsCL[White]}ServerRack Wattage ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${APCPDU_WATT}`'watts ${idsCL[Default]}~ estimate"
@@ -188,7 +190,7 @@ CHECKPOWER(){
echo -e "${idsCL[Yellow]}Offsite Power Information ${idsCL[LightYellow]}${avgdayshdr}"
DIVIDER . yellow 75
echo -en "${idsCL[Yellow]}Pulling data from 'Offsite' ... "
[ ${REPORT} -eq 0 ] && echo -en "${idsCL[Yellow]}Pulling data from 'Offsite' ... "
upsinfo=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 admin@10.2.1.1 'upsc CP1500PFCLCD')
if [ "$(echo "${upsinfo}" | grep 'input.voltage:')" != "" ]; then
@@ -219,7 +221,7 @@ CHECKPOWER(){
fi
echo -en "\r\033[K"
[ ${REPORT} -eq 0 ] && echo -en "\r\033[K"
echo -e "${idsCL[White]}UPS Voltage In ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OFFSITE_VOLTIN}`'volts${idsCL[Default]}"
echo -e "${idsCL[White]}UPS Voltage Out ${idsCL[Default]}: ${idsCL[Green]}`IDS_NUMBER_FORMAT ${OFFSITE_VOLTOUT}`'volts${idsCL[Default]}"
echo
@@ -254,7 +256,7 @@ CHECKPOWER(){
gochk=1
fi
if [ ${gochk} -eq 1 ]; then
echo -en "${idsCL[Yellow]}Pulling data for '${SENSOR}' ... "
[ ${REPORT} -eq 0 ] && echo -en "${idsCL[Yellow]}Pulling data for '${SENSOR}' ... "
HOST_WATT_SENSORS=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.8.1 -O vq 2> /dev/null | sed -e 's/"//g')
IFS=$'\n'
@@ -300,7 +302,8 @@ CHECKPOWER(){
fi
MSG="${idsCL[White]}${SENSOR} ${idsCL[Default]}: ${HOST_WATTS_disp}"
echo -en "\r\033[K${MSG}"
[ ${REPORT} -eq 0 ] && echo -en "\r\033[K"
echo -en "${MSG}"
if [ "${HOST_WATT_SENSORS}" != "" ]; then
if [ "${avgdays}" != "" ] && [ ${HOST_WATTS} -gt 0 ]; then