@@ -1456,19 +1456,19 @@ SHUTDOWN_SERVER(){
else
ESXIHOST=''
fi
echo -e "\n${idsCL[Yellow]}ESXi Host Powerdown"
DIVIDER . yellow 75
# echo -e "\n${idsCL[Yellow]}ESXi Host Powerdown"
# DIVIDER . yellow 75
if [ "${ESXIHOST}" != "" ]; then
host=${PW_ESXI_HOST_NAMES[${ESXIHOST}]}
c=0; spcA=''; spc1=`expr 21 - ${#host} - 1`; until [ ${c} = ${spc1} ]; do spcA="${spcA} "; c=`expr ${c} + 1`; done
c=0; spcB=''; spc1=`expr 18 - ${#ESXIHOST} - 1`; until [ ${c} = ${spc1} ]; do spcB="${spcB} "; c=`expr ${c} + 1`; done
echo -en "${idsCL[LightCyan]} Host: ${idsCL[Green]}${host}${spcA}"
echo -en "${idsCL[LightCyan]}Host IP: ${idsCL[Green]}${ESXIHOST}${spcB}"
echo -e "${idsCL[LightCyan]}iDrac IP: ${idsCL[Green]}${PW_HOST_IDRACS[${host}]}${idsCL[Default]}"
DIVIDER . yellow 75
echo
# c=0; spcA=''; spc1=`expr 21 - ${#host} - 1`; until [ ${c} = ${spc1} ]; do spcA="${spcA} "; c=`expr ${c} + 1`; done
# c=0; spcB=''; spc1=`expr 18 - ${#ESXIHOST} - 1`; until [ ${c} = ${spc1} ]; do spcB="${spcB} "; c=`expr ${c} + 1`; done
# echo -en "${idsCL[LightCyan]} Host: ${idsCL[Green]}${host}${spcA}"
# echo -en "${idsCL[LightCyan]}Host IP: ${idsCL[Green]}${ESXIHOST}${spcB}"
# echo -e "${idsCL[LightCyan]}iDrac IP: ${idsCL[Green]}${PW_HOST_IDRACS[${host}]}${idsCL[Default]}"
# DIVIDER . yellow 75
# echo
echo "($(date +'%Y-%m-%d %H:%M:%S')) - Shutting down ${host} (${ESXIHOST})" >> ${PW_LOGFILE}
@@ -1583,7 +1583,13 @@ HOSTMGMT(){
([ "${HOST}" == "" ] || ([ "${POWER}" == "" ] && [ "${ESXI}" == "" ])) && echo -e "Invalid command arguments\n" && exit 1
if [ "${MODE}" == "esxi" ]; then
([ "${ESXI}" == "maint" ] || [ "${ESXI}" == "maintenance" ] || [ "${ESXI}" == "mm" ]) && SHUTDOWN_SERVER ${HOST} maintenance || SHUTDOWN_SERVER ${HOST}
if [ "${ESXI}" == "maint" ] || [ "${ESXI}" == "maintenance" ] || [ "${ESXI}" == "mm" ]; then
echo -e "${idsCL[LightGreen]}PUTTING HOST INTO MAINTENANCE MODE${idsCL[Default]}\n"
SHUTDOWN_SERVER ${HOST} maintenance
else
echo -e "${idsCL[LightGreen]}SHUTTING DOWN HOST${idsCL[Default]}\n"
SHUTDOWN_SERVER ${HOST}
fi
elif [ "${MODE}" == "power" ]; then
HOSTPOWER ${HOST} ${POWER}
@@ -1631,14 +1637,14 @@ HOSTPOWER(){
fi
if [ "${idracip}" != "" ]; then
host=${PW_iDRACHOST_SHORTNAMES[${idracip}]}
c=0; spcA=''; spc1=`expr 21 - ${#host} - 1`; until [ ${c} = ${spc1} ]; do spcA="${spcA} "; c=`expr ${c} + 1`; done
c=0; spcB=''; spc1=`expr 18 - ${#PW_HOST_ADDRESSES[${host}]} - 1`; until [ ${c} = ${spc1} ]; do spcB="${spcB} "; c=`expr ${c} + 1`; done
echo -en "${idsCL[LightCyan]} Host: ${idsCL[Green]}${host}${spcA}"
echo -en "${idsCL[LightCyan]}Host IP: ${idsCL[Green]}${PW_HOST_ADDRESSES[${host}]}${spcB}"
echo -e "${idsCL[LightCyan]}iDrac IP: ${idsCL[Green]}${idracip}${idsCL[Default]}"
DIVIDER . yellow 75
echo
# host=${PW_iDRACHOST_SHORTNAMES[${idracip}]}
# c=0; spcA=''; spc1=`expr 21 - ${#host} - 1`; until [ ${c} = ${spc1} ]; do spcA="${spcA} "; c=`expr ${c} + 1`; done
# c=0; spcB=''; spc1=`expr 18 - ${#PW_HOST_ADDRESSES[${host}]} - 1`; until [ ${c} = ${spc1} ]; do spcB="${spcB} "; c=`expr ${c} + 1`; done
# echo -en "${idsCL[LightCyan]} Host: ${idsCL[Green]}${host}${spcA}"
# echo -en "${idsCL[LightCyan]}Host IP: ${idsCL[Green]}${PW_HOST_ADDRESSES[${host}]}${spcB}"
# echo -e "${idsCL[LightCyan]}iDrac IP: ${idsCL[Green]}${idracip}${idsCL[Default]}"
# DIVIDER . yellow 75
# echo
if [ "${2^^}" == "ON" ] || [ "${2^^}" == "OFF" ] || [ "${2^^}" == "STATUS" ]; then
if [ "${idracip}" == "10.10.2.20" ] && [ "${2^^}" == "ON" ]; then