Update temp.inc.sh

This commit is contained in:
2024-06-30 12:05:53 -05:00
parent 80905e10a2
commit 1fea2f384f

View File

@@ -417,7 +417,7 @@ CHECKTEMP(){
if [ ${#vHOST_TEMPNAMES[@]} -gt 1 ]; then
t=1
for sensorname in "${vHOST_TEMPNAMES[@]}"; do
if [ "${TTYPE}" != "fans" ] || ([ "${TTYPE}" == "fans" ] && [[ "${sensorname}" = *"Exhaust"* ]]); then
if [ "${TTYPE}" != "fans" ] || ([ "${TTYPE}" == "fans" ] && ([[ "${sensorname}" = *"Exhaust"* ]] || ([ "${SENSOR}" == "iDS-vMS-Host6" ] && [[ "${sensorname}" = *"Inlet"* ]]))); then
temp_warn=$(snmpwalk -v 1 -c public -t 2 ${vHOSTiDRACIP} .1.3.6.1.4.1.674.10892.5.4.700.20.1.11.1.${t} -O vq | sed -e 's/"//g')
temp_warn=`echo "scale=1; ${temp_warn}/10" | bc`; temp_warn=`echo $(bc <<< "scale=2; ((${temp_warn}*(9/5))+32)/1") | awk '{print int($1+0.5)}'`
temp_crit=$(snmpwalk -v 1 -c public -t 2 ${vHOSTiDRACIP} .1.3.6.1.4.1.674.10892.5.4.700.20.1.10.1.${t} -O vq | sed -e 's/"//g')
@@ -616,8 +616,8 @@ CHECKTEMP(){
if [ "${TTYPE}" == "fans" ] && [ "${SENSOR}" == "iDS-vMS-Host6" ] && [ ! -f ${PW_TMPFOLDER}/${SENSOR}.down ]; then
if [[ "${PW_ESXI_FANSPEEDCONTROL_HOSTS}" = *"${PW_HOST_IDRACS[iDS-vMS-Host6]}"* ]]; then
echo -e "${idsCL[LightYellow]}${SENSOR} PSU is not compatible, Fans are instead synced with 'iDS-vMS-Host7'${idsCL[Default]}"
else
echo -e " xFans are not managed for this host"
# else
# echo -e " xFans are not managed for this host"
fi
fi
# ([ "${TTYPE}" != "fans" ] || ([ "${TTYPE}" == "fans" ] && [ "${SENSOR}" != "iDS-vMS-Host6" ])) && echo