This commit is contained in:
2024-05-15 20:52:51 -05:00
parent c9a07446c7
commit 3d7afa0d01
2 changed files with 29 additions and 3 deletions

View File

@@ -1,6 +1,6 @@
#!/usr/bin/env bash
VERS='2.7.48-05132024'
VERS='2.7.49-05152024'
noheader=' update service dailytemp confsync -r -report '

View File

@@ -375,8 +375,13 @@ CHECKPOWER(){
[ "${avgdays}" != "" ] && echo -e " --${idsCL[LightYellow]}${avgdays_disp}-Averages---"
echo -en "${idsCL[LightCyan]}Totals Amps Watts"
[ "${avgdays}" != "" ] && echo -e " Amps Watts" || echo
(( $(bc <<<"${OFFSITE_AMPS} < ${TOTAL_MISC_WATTS}") )) && AD=${TOTAL_MISC_AMPS} || AD=${OFFSITE_AMPS}
(( $(bc <<<"${OFFSITE_WATTS} < ${TOTAL_MISC_WATTS}") )) && AW=${TOTAL_MISC_WATTS} || AW=${OFFSITE_WATTS}
if (( $(bc <<<"${OFFSITE_WATTS} < ${TOTAL_MISC_WATTS}") )); then
AW=${TOTAL_MISC_WATTS}
AD=${TOTAL_MISC_AMPS}
else
AW=${OFFSITE_WATTS}
AD=${OFFSITE_AMPS}
fi
AD=$(IDS_NUMBER_FORMAT ${AD} 2 yes); c=0; spc=''; spc1=`expr ${wspc} - ${#AD}`; until [ ${c} = ${spc1} ]; do spc="${spc} "; ((c++)); done
echo -en "${idsCL[White]}Offsite Equipment ${idsCL[Default]}: ${idsCL[Green]}${AD}'A${spc}`IDS_NUMBER_FORMAT ${AW} 0`'W"
if [ "${avgdays}" != "" ]; then
@@ -779,6 +784,15 @@ OFFSITE_CHECKPOWER_SERVICE(){
OFFSITE_BATT_RUNTIME=`echo "scale=2; ${OFFSITE_BATT_RUNTIME}/60" | bc`
OFFSITE_BATT_CAP=$(echo "${upsinfo}" | grep 'battery.charge:' | sed 's/.*: //')
if [ ${OFFSITE_WATTS} < 100 ]; then
TOTAL_MISC_WATTS=0
for mSENSOR in "${!OFFSITE_MISC[@]}"; do
IFS=: read -r AMP WATT VOLT <<< ${OFFSITE_MISC[${mSENSOR}]}; unset IFS
TOTAL_MISC_WATTS=`echo "scale=2; ${TOTAL_MISC_WATTS}+${WATT}" | bc`
done
(( $(bc <<<"${OFFSITE_WATTS} < ${TOTAL_MISC_WATTS}") )) && OFFSITE_WATTS=${TOTAL_MISC_WATTS}
fi
if [ ! -d /sys/bus/w1/devices/${PW_SENSOR_DEVICEID['Offsite-ServerRoom']} ]; then
/bin/dtoverlay w1-gpio gpiopin=4
sleep 2s
@@ -981,6 +995,18 @@ POWERLOGGER_SERVICE(){
OFFSITE_WATTS=`echo "scale=2; ${OFFSITE_LOAD}*$(echo "${upsinfo}" | grep 'ups.realpower.nominal:' | sed 's/.*: //')" | bc`
OFFSITE_AMPS=`echo "scale=2; ${OFFSITE_WATTS}/${OFFSITE_VOLTOUT}" | bc`
if [ ${OFFSITE_WATTS} < 100 ]; then
TOTAL_MISC_WATTS=0; TOTAL_MISC_AMPS=0
for mSENSOR in "${!OFFSITE_MISC[@]}"; do
IFS=: read -r AMP WATT VOLT <<< ${OFFSITE_MISC[${mSENSOR}]}; unset IFS
TOTAL_MISC_WATTS=`echo "scale=2; ${TOTAL_MISC_WATTS}+${WATT}" | bc`
TOTAL_MISC_AMPS=`echo "scale=2; ${TOTAL_MISC_AMPS}+${AMP}" | bc`
done
if (( $(bc <<<"${OFFSITE_WATTS} < ${TOTAL_MISC_WATTS}") )); then
OFFSITE_WATTS=${TOTAL_MISC_WATTS}
OFFSITE_AMPS=${TOTAL_MISC_AMPS}
fi
fi
QRY="INSERT INTO power_data (\`sensorid\`, \`date\`, \`volt\`, \`amp\`, \`watt\`) VALUES ('${PW_POWERSENSOR_ID['offsite-ups']}','${LogDataTime}','${OFFSITE_VOLTOUT}','${OFFSITE_AMPS}','${OFFSITE_WATTS}')"
${mysql_conn} -e "USE servermonitor; ${QRY}"
fi