Update powerwall.sh

This commit is contained in:
2023-11-06 18:51:40 -06:00
parent 445ee307f6
commit 6aeab7e7e8

View File

@@ -48,8 +48,8 @@ CHECKTEMP(){
FanSpeed=`echo "scale=2; ${vHOSTFAN}/21200" | bc`; FanSpeed=`echo "scale=0; ${FanSpeed}*100" | bc | sed -e 's/.00//g'`
if [ ${FanSpeed} -gt 92 ]; then
SENDNOTICE "${vHOSTiDRACIP} Fan Issue" "Workaround commands sent to set the Fans at 30%" 1
ipmitool -I lanplus -H ${vHOSTiDRACIP} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00
ipmitool -I lanplus -H ${vHOSTiDRACIP} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0x1E
ipmitool -I lanplus -H ${vHOSTiDRACIP} -U ${PW_ESXI_USER} -P "'${PW_ESXI_PASS}'" raw 0x30 0x30 0x01 0x00
ipmitool -I lanplus -H ${vHOSTiDRACIP} -U ${PW_ESXI_USER} -P "'${PW_ESXI_PASS}'" raw 0x30 0x30 0x02 0xff 0x1E
fi
fi
@@ -236,9 +236,9 @@ CHECKTEMP_SERVICE(){
echo "HERE: ${vHOSTFAN} - ${FanSpeed}"
if [ ${FanSpeed} -gt 92 ]; then
SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} Fan Issue" "Workaround commands sent to set the Fans at 30%25" 1
echo "ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00"
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0xff
echo "ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "'${PW_ESXI_PASS}'" raw 0x30 0x30 0x01 0x00"
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "'${PW_ESXI_PASS}'" raw 0x30 0x30 0x01 0x00
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "'${PW_ESXI_PASS}'" raw 0x30 0x30 0x02 0xff 0xff
FanSpeed=30
fi
fi
@@ -314,8 +314,8 @@ CHECKTEMP_SERVICE(){
# iDS-vMS-Offsite Fan Issue Workaround
if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ] && [ ${FanSpeed} -ne 80 ]; then
SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} SERVER WARM" "Setting fan speeds to 80%25" 1
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0x50
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "'${PW_ESXI_PASS}'" raw 0x30 0x30 0x01 0x00
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "'${PW_ESXI_PASS}'" raw 0x30 0x30 0x02 0xff 0x50
fi
fi
@@ -377,8 +377,8 @@ Previous Temp: ${last_temp[${SENSOR}]}'F"
# iDS-vMS-Offsite Fan Issue Workaround
if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ] && [ ${FanSpeed} -ne 30 ]; then
SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} Fan Issue" "Settings fans back to normal 30%25"
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0x1E
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "'${PW_ESXI_PASS}'" raw 0x30 0x30 0x01 0x00
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "'${PW_ESXI_PASS}'" raw 0x30 0x30 0x02 0xff 0x1E
fi
fi
@@ -1372,7 +1372,7 @@ HOSTPOWER(){
fi
echo -e "${idsCL[Green]}"
ipmitool -I lanplus -H ${idracip} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" chassis power ${2,,}
ipmitool -I lanplus -H ${idracip} -U ${PW_ESXI_USER} -P "'${PW_ESXI_PASS}'" chassis power ${2,,}
echo -e "${idsCL[Default]}"
if [ "${idracip}" == "10.10.2.20" ] && [ "${2,,}" == "off" ]; then