Update offsite-power-check.sh

This commit is contained in:
2023-11-05 14:21:41 -06:00
parent ccc3b34291
commit 83b426c084

View File

@@ -31,7 +31,7 @@ if [ "$(CHECK_HOST 10.2.1.1)" != "false" ]; then
OFFSITE_BATT_RUNTIME=`echo "scale=2; ${OFFSITE_BATT_RUNTIME}/60" | bc`
OFFSITE_BATT_CAP=$(echo "${upsinfo}" | grep 'battery.charge:' | sed 's/.*: //')
if (( $(bc <<<"${OFFSITE_VOLTIN} > 105") )); then
if [ ${OFFSITE_VOLTIN%.*} > 105 ]; then
if [ -f ${PW_TMPFOLDER}/power.offsite.ac.low ]; then
echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${OFFSITE_VOLTIN}'Volts - Offsite Back to Normal Voltage" >> ${PW_LOGPOWER}
echo "($(date +'%Y-%m-%d %H:%M:%S')) - ${OFFSITE_VOLTIN}'Volts - OFFSITE POWER NOMINAL AGAIN" >> ${PW_LOGFILE}
@@ -65,7 +65,7 @@ BATT RUNTIME: ${OFFSITE_BATT_RUNTIME}'Mins" 1
touch ${PW_TMPFOLDER}/power.offsite.ac.low
fi
if (( $(bc <<<"${OFFSITE_BATT_CAP} <= 95") )) && [ ! -f ${PW_TMPFOLDER}/power.offsite.off ]; then
if [ ${OFFSITE_BATT_CAP%.*} < 95 ] && [ ! -f ${PW_TMPFOLDER}/power.offsite.off ]; then
SENDNOTICE2 "OFFSITE HOST POWER" "Powering DOWN offsite host(s) due to power outage" 1
# SHUTDOWN_OFFSITE &
touch ${PW_TMPFOLDER}/power.offsite.off