Update powerwall.sh
This commit is contained in:
30
powerwall.sh
30
powerwall.sh
@@ -740,20 +740,18 @@ CHECKPOWER(){
|
||||
if [ ${gochk} -eq 1 ]; then
|
||||
echo -en "${idsCL[Yellow]}Pulling data for '${SENSOR}' ... "
|
||||
|
||||
# HOST_WATTS=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.6.1.3 | sed 's/.*: //')
|
||||
# if [ "${HOST_WATTS}" = "" ]; then
|
||||
HOST_WATT_SENSORS=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.8.1 -O vq | sed -e 's/"//g')
|
||||
IFS=$'\n'
|
||||
read -rd '' -a HOST_WATT_SENSORS <<<"${HOST_WATT_SENSORS}"
|
||||
unset IFS
|
||||
HOST_WATT_SENSORS=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.8.1 -O vq | sed -e 's/"//g')
|
||||
IFS=$'\n'
|
||||
read -rd '' -a HOST_WATT_SENSORS <<<"${HOST_WATT_SENSORS}"
|
||||
unset IFS
|
||||
if [[ "${HOST_WATT_SENSORS}" != *"Timeout"* ]]; then
|
||||
found=0; PS1='0.0'; PS2='0.0'
|
||||
for s in {1..5}; do
|
||||
DP=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.8.1.${s} | sed 's/.*: //')
|
||||
if [[ "${DP}" = *"System Board"* ]]; then
|
||||
found=1
|
||||
HOST_WATTS=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.6.1.${s} | sed 's/.*: //')
|
||||
# break
|
||||
|
||||
|
||||
elif [[ "${DP}" = *"PS1"* ]]; then
|
||||
PS1=$(snmpwalk -t 1 -r 0 -v 1 -c public ${PW_HOST_IDRACS[${SENSOR}]} iso.3.6.1.4.1.674.10892.5.4.600.30.1.6.1.${s} | sed 's/.*: //')
|
||||
elif [[ "${DP}" = *"PS2"* ]]; then
|
||||
@@ -765,18 +763,22 @@ CHECKPOWER(){
|
||||
[ "${PS2}" != "0.0" ] && PS2=`echo "scale=1; ${PS2}/10" | bc` && (( $(bc <<<"${PS2} < 1") )) && [[ "${PS2}" = *"."* ]] && PS2="0${PS2}"
|
||||
HOST_AMPS=`echo "scale=1; ${PS1}+${PS2}" | bc`
|
||||
[[ "${HOST_WATTS}" = *"Timeout"* ]] && HOST_WATTS_disp="${idsCL[LightRed]}Host Offline" || HOST_WATTS_disp="${idsCL[Green]}${HOST_AMPS}'amps - `IDS_NUMBER_FORMAT ${HOST_WATTS}`'watts"
|
||||
|
||||
|
||||
elif [ "$(ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSOR}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" chassis power status | grep off)" != "" ]; then
|
||||
HOST_WATTS_disp="${idsCL[LightRed]}Host offline"
|
||||
|
||||
HOST_WATTS_disp="${idsCL[LightRed]}Host powered down"
|
||||
|
||||
elif [ "${HOST_WATTS}" == "0" ]; then
|
||||
HOST_WATTS_disp="${idsCL[Yellow]}Host PSU not capable"
|
||||
|
||||
|
||||
else
|
||||
HOST_WATTS_disp="${idsCL[LightRed]}Could not pull data"
|
||||
|
||||
|
||||
fi
|
||||
# fi
|
||||
|
||||
else
|
||||
HOST_WATTS_disp="${idsCL[LightRed]}Host offline"
|
||||
fi
|
||||
|
||||
MSG="${idsCL[White]}${SENSOR} ${idsCL[Default]}: ${HOST_WATTS_disp}"
|
||||
echo -en "\r\033[K${MSG}"
|
||||
|
||||
|
||||
Reference in New Issue