Update powerwall.sh

This commit is contained in:
2022-09-03 14:11:32 -05:00
parent e59d2fce19
commit 9eced6f0de

View File

@@ -35,6 +35,7 @@ CHECKTEMP(){
}
CHECKTEMP_SERVICE(){
last_temp=0
mqtt_message=`${mqtt_conn} -t tele/${1}/SENSOR -C 1`
while true
do
@@ -52,11 +53,11 @@ CHECKTEMP_SERVICE(){
echo ${TEMP_THRESHOLDS[${1}]} | cut -d',' -f 2 | read temp_crit
if [ $(bc -l <<< "$temp_f >= $temp_warn") -eq 1 ] && [ $(bc -l <<< "$temp_f < $temp_crit") -eq 1 ]; then
echo "WARNING TEMP: $temp_f°F" | mail -s "${1} TEMP WARNING" $email_alert
[ "$last_temp" != $"temp_c" ] && echo "WARNING TEMP: $temp_f°F" | mail -s "${1} TEMP WARNING" $email_alert
echo "($temp_d @ $temp_t) WARNING: $temp_f°F"
elif [ $(bc -l <<< "$temp_f >= $temp_crit") -eq 1 ]; then
echo "CRITICAL TEMP: $temp_f°F" | mail -s "${1} TEMP CRITICAL" $email_alert
[ "$last_temp" != $"temp_c" ] && echo "CRITICAL TEMP: $temp_f°F" | mail -s "${1} TEMP CRITICAL" $email_alert
echo "($temp_d @ $temp_t) CRITICAL: $temp_f°F"
else
@@ -66,6 +67,7 @@ CHECKTEMP_SERVICE(){
QRY="USE servermonitor; INSERT INTO sensor_data (\`sensorid\`, \`date\`, \`temp\`, \`hum\`) VALUES ('${SENSOR_ID[$1]}','${temp_d} ${temp_t}','${temp_f}','${temp_h}')"
# ${mysql_conn} -e "${QRY}"
last_temp=$temp_c
fi
done
sleep 10