update
This commit is contained in:
@@ -1,6 +1,6 @@
|
||||
#!/usr/bin/env bash
|
||||
|
||||
VERS='2.8.2-11102024'
|
||||
VERS='2.8.3-11162024'
|
||||
|
||||
noheader=' update service dailytemp confsync -r -report test '
|
||||
|
||||
@@ -57,11 +57,13 @@ PW_MAINHOSTS=(${PW_MAIN_HOSTS})
|
||||
PW_SYSHOSTS=(${PW_SYS_HOSTS})
|
||||
PW_OFFSITEHOSTS=(${PW_OFFSITE_HOSTS})
|
||||
PW_ALLHOSTS=(${PW_ALL_HOSTS})
|
||||
PW_CONSERVEHOSTS=(${PW_CONSERVE_HOSTS})
|
||||
PW_ESXI_FANSPEEDCONTROLHOSTS=(${PW_ESXI_FANSPEEDCONTROL_HOSTS})
|
||||
[ "${PW_TEMPIND_RANGE}" != "" ] && PW_TEMPIND_RANGE=(${PW_TEMPIND_RANGE})
|
||||
unset IFS
|
||||
|
||||
[ ! -f ${PW_ISCSI-PRI_HOST} ] && PW_ISCSI-PRI_HOST=10.10.2.10
|
||||
[ ! -f ${PW_ISCSI-SYS_HOST} ] && PW_ISCSI-PRI_HOST=10.10.2.16
|
||||
|
||||
if [ -f ${PW_FOLDER}/conf/settings.local.conf ]; then
|
||||
declare -A PW_POWERWALL_SERVICES
|
||||
declare -A PW_THRESHOLDS
|
||||
|
||||
@@ -1241,7 +1241,7 @@ HOSTPOWER(){
|
||||
if [ "${idracip}" != "" ]; then
|
||||
|
||||
if [ "${2^^}" = "ON" ] || [ "${2^^}" = "OFF" ] || [ "${2^^}" = "STATUS" ]; then
|
||||
if [ "${idracip}" = "10.10.2.20" ] && [ "${2^^}" = "ON" ]; then
|
||||
if [ "${idracip}" = "${PW_HOST_IDRACS[${PW_ESXI_HOST_NAMES[${PW_ISCSI-PRI_HOST}]}" ] && [ "${2^^}" = "ON" ]; then
|
||||
MSG="Powering ON the SAS Enclosure"
|
||||
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
|
||||
echo -en "\n${idsCL[LightCyan]}${MSG}${MSG_SPC}: "
|
||||
@@ -1273,12 +1273,12 @@ HOSTPOWER(){
|
||||
fi
|
||||
echo -e "${idsCL[Default]}"
|
||||
|
||||
if [ "${idracip}" = "10.10.2.20" ] && [ "${2^^}" = "OFF" ]; then
|
||||
if [ "${idracip}" = "${PW_HOST_IDRACS[${PW_ESXI_HOST_NAMES[${PW_ISCSI-PRI_HOST}]}]}" ] && [ "${2^^}" = "OFF" ]; then
|
||||
MSG="Powering OFF the SAS Enclosure"
|
||||
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
|
||||
echo -en "${idsCL[LightCyan]}${MSG}${MSG_SPC}: "
|
||||
if [ "${TEST}" != "true" ]; then
|
||||
if [ "$(CHECK_HOST 10.10.2.10)" = "false" ]; then
|
||||
if [ "$(CHECK_HOST ${PW_ISCSI-PRI_HOST})" = "false" ]; then
|
||||
run=$(snmpset -v 1 -c private ${PW_APCPDU_IP} .1.3.6.1.4.1.318.1.1.12.3.3.1.1.4.14 i 2 >/dev/null 2>&1)
|
||||
sleep 3s
|
||||
echo -e "${idsCL[Green]}Done${idsCL[Default]}\n"
|
||||
|
||||
64
powerwall.sh
64
powerwall.sh
@@ -160,30 +160,7 @@ CONSERVE_POWER(){
|
||||
SHUTDOWN_SERVER ${PW_MAIN_ISCSI} -esxi off
|
||||
SHUTDOWN_SERVER 10.10.2.16 -esxi off
|
||||
}
|
||||
COOLDOWN_SRVRM(){
|
||||
# ${PW_FOLDER}/esxi-scripts/cooldown.ps1
|
||||
sleep 20
|
||||
SHUTDOWN_SERVER 10.10.2.16 -esxi off
|
||||
SHUTDOWN_SERVER 10.10.2.10 -esxi off
|
||||
${PW_FOLDER}/esxi-scripts/set-drs.ps1 2
|
||||
}
|
||||
COOLDOWN_SRVRM_OVERNIGHT(){
|
||||
if [ "${1}" == "OFF" ]; then
|
||||
echo "Cooling off server room for the night"
|
||||
${PW_FOLDER}/esxi-scripts/cooldown.overnight.ps1
|
||||
sleep 20
|
||||
SHUTDOWN_SERVER 10.10.2.16 -esxi off
|
||||
sleep 60
|
||||
${PW_FOLDER}/esxi-scripts/set-drs.ps1 2
|
||||
|
||||
elif [ "${1}" == "ON" ]; then
|
||||
echo "opposite of Cooling off server room for the night"
|
||||
${PW_SCRIPT} host 6 -p on
|
||||
sleep 420
|
||||
${PW_FOLDER}/esxi-scripts/coolup.overnight.ps1
|
||||
fi
|
||||
|
||||
}
|
||||
|
||||
MAINT_MODE_VERIFY_SHUTDOWN(){
|
||||
ESXIHOST=${1}
|
||||
MaintMode=""
|
||||
@@ -282,10 +259,10 @@ SHUTDOWN_SERVER(){
|
||||
fi
|
||||
fi
|
||||
|
||||
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ] || [ "${ESXI_HOST}" == "SYS" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
||||
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
||||
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ] || [ "${ESXI_HOST}" == "SYS" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
||||
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
||||
MSG="Stopping all iSCSI-PRI VM's"
|
||||
elif [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "SYS" ]; then
|
||||
elif [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "SYS" ]; then
|
||||
MSG="Stopping all iSCSI-SYS VM's"
|
||||
elif [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ]; then
|
||||
MSG="Stopping all iSCSI VM's"
|
||||
@@ -293,9 +270,9 @@ SHUTDOWN_SERVER(){
|
||||
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
|
||||
echo -en "${idsCL[White]}${MSG}${idsCL[White]}${MSG_SPC}: "
|
||||
if [ "${TEST}" != "true" ]; then
|
||||
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
||||
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
||||
${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown.ps1 >/dev/null 2>&1 &
|
||||
elif [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "SYS" ]; then
|
||||
elif [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "SYS" ]; then
|
||||
${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown.ps1 >/dev/null 2>&1 &
|
||||
elif [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ]; then
|
||||
${PW_FOLDER}/esxi-scripts/iscsi-all-vm-shutdown.ps1 >/dev/null 2>&1 &
|
||||
@@ -378,15 +355,15 @@ SHUTDOWN_SERVER(){
|
||||
echo
|
||||
fi
|
||||
|
||||
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ] || [ "${ESXI_HOST}" == "SYS" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
||||
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ] || [ "${ESXI_HOST}" == "SYS" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
||||
MSG="Waiting for iSCSI VM's to power down"
|
||||
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
|
||||
echo -en "${idsCL[White]}${MSG}${idsCL[White]}${MSG_SPC}: "
|
||||
# for ESXIHOST in "${PW_MAINSITEHOSTS[@]}"; do
|
||||
if [ "${TEST}" != "true" ]; then
|
||||
if [ "${1}" == "10.10.2.10" ] || [ "${1}" == "MAIN" ]; then
|
||||
if [ "${1}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${1}" == "MAIN" ]; then
|
||||
${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown-verify.ps1 >/dev/null 2>&1
|
||||
elif [ "${1}" == "10.10.2.17" ] || [ "${1}" == "SYS" ]; then
|
||||
elif [ "${1}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${1}" == "SYS" ]; then
|
||||
${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown-verify.ps1 >/dev/null 2>&1
|
||||
elif [ "${1}" == "MAINSITE" ] || [ "${1}" == "ALL" ]; then
|
||||
${PW_FOLDER}/esxi-scripts/iscsi-all-shutdown-verify.ps1 >/dev/null 2>&1
|
||||
@@ -412,9 +389,9 @@ SHUTDOWN_SERVER(){
|
||||
# echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}"
|
||||
# fi
|
||||
|
||||
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
||||
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
||||
MSG="Shutting down iSCSI-PRI Server"
|
||||
elif [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "SYS" ]; then
|
||||
elif [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "SYS" ]; then
|
||||
MSG="Shutting down iSCSI-SYS Server"
|
||||
elif [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ]; then
|
||||
MSG="Shutting down both iSCSI-PRI & iSCSI-SYS Servers"
|
||||
@@ -422,13 +399,13 @@ SHUTDOWN_SERVER(){
|
||||
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
|
||||
echo -en "${idsCL[White]}${MSG}${MSG_SPC}: "
|
||||
if [ "${TEST}" != "true" ]; then
|
||||
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
||||
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 10.10.2.10 >/dev/null 2>&1 &
|
||||
elif [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "SYS" ]; then
|
||||
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 10.10.2.17 >/dev/null 2>&1 &
|
||||
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
|
||||
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${PW_ISCSI-PRI_HOST} >/dev/null 2>&1 &
|
||||
elif [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "SYS" ]; then
|
||||
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${PW_ISCSI-SYS_HOST} >/dev/null 2>&1 &
|
||||
elif [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ]; then
|
||||
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 10.10.2.10 >/dev/null 2>&1 &
|
||||
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 10.10.2.17 >/dev/null 2>&1 &
|
||||
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${PW_ISCSI-PRI_HOST} >/dev/null 2>&1 &
|
||||
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${PW_ISCSI-SYS_HOST} >/dev/null 2>&1 &
|
||||
fi
|
||||
echo -e "${idsCL[Green]}Command sent${idsCL[Default]}"
|
||||
else
|
||||
@@ -521,9 +498,9 @@ SHUTDOWN_SERVER(){
|
||||
}
|
||||
|
||||
VERIFY_ISCSI_VM_DOWN(){
|
||||
if [ "${1}" == "10.10.2.10" ] || [ "${1}" == "MAIN" ]; then
|
||||
if [ "${1}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${1}" == "MAIN" ]; then
|
||||
${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown-verify.ps1 >/dev/null 2>&1
|
||||
elif [ "${1}" == "10.10.2.17" ] || [ "${1}" == "SYS" ]; then
|
||||
elif [ "${1}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${1}" == "SYS" ]; then
|
||||
${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown-verify.ps1 >/dev/null 2>&1
|
||||
elif [ "${1}" == "MAINSITE" ] || [ "${1}" == "ALL" ]; then
|
||||
${PW_FOLDER}/esxi-scripts/iscsi-all-shutdown-verify.ps1 >/dev/null 2>&1
|
||||
@@ -1042,9 +1019,6 @@ fi
|
||||
|
||||
dl|downlist) DOWNLIST;;
|
||||
|
||||
cooldown) COOLDOWN_SRVRM;;
|
||||
cooldown-overnight) COOLDOWN_SRVRM_OVERNIGHT ${2};;
|
||||
|
||||
oldhelp)
|
||||
echo -e "${idsCL[White]} Usage: ${idsCL[LightYellow]}[powerwall or pw]${idsCL[LightCyan]} {option}"
|
||||
echo
|
||||
|
||||