This commit is contained in:
2024-11-16 16:42:23 -06:00
parent 1b1b9f3119
commit b1c8927b9b
3 changed files with 26 additions and 50 deletions

View File

@@ -160,30 +160,7 @@ CONSERVE_POWER(){
SHUTDOWN_SERVER ${PW_MAIN_ISCSI} -esxi off
SHUTDOWN_SERVER 10.10.2.16 -esxi off
}
COOLDOWN_SRVRM(){
# ${PW_FOLDER}/esxi-scripts/cooldown.ps1
sleep 20
SHUTDOWN_SERVER 10.10.2.16 -esxi off
SHUTDOWN_SERVER 10.10.2.10 -esxi off
${PW_FOLDER}/esxi-scripts/set-drs.ps1 2
}
COOLDOWN_SRVRM_OVERNIGHT(){
if [ "${1}" == "OFF" ]; then
echo "Cooling off server room for the night"
${PW_FOLDER}/esxi-scripts/cooldown.overnight.ps1
sleep 20
SHUTDOWN_SERVER 10.10.2.16 -esxi off
sleep 60
${PW_FOLDER}/esxi-scripts/set-drs.ps1 2
elif [ "${1}" == "ON" ]; then
echo "opposite of Cooling off server room for the night"
${PW_SCRIPT} host 6 -p on
sleep 420
${PW_FOLDER}/esxi-scripts/coolup.overnight.ps1
fi
}
MAINT_MODE_VERIFY_SHUTDOWN(){
ESXIHOST=${1}
MaintMode=""
@@ -282,10 +259,10 @@ SHUTDOWN_SERVER(){
fi
fi
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ] || [ "${ESXI_HOST}" == "SYS" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ] || [ "${ESXI_HOST}" == "SYS" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
MSG="Stopping all iSCSI-PRI VM's"
elif [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "SYS" ]; then
elif [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "SYS" ]; then
MSG="Stopping all iSCSI-SYS VM's"
elif [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ]; then
MSG="Stopping all iSCSI VM's"
@@ -293,9 +270,9 @@ SHUTDOWN_SERVER(){
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
echo -en "${idsCL[White]}${MSG}${idsCL[White]}${MSG_SPC}: "
if [ "${TEST}" != "true" ]; then
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown.ps1 >/dev/null 2>&1 &
elif [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "SYS" ]; then
elif [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "SYS" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown.ps1 >/dev/null 2>&1 &
elif [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-all-vm-shutdown.ps1 >/dev/null 2>&1 &
@@ -378,15 +355,15 @@ SHUTDOWN_SERVER(){
echo
fi
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ] || [ "${ESXI_HOST}" == "SYS" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ] || [ "${ESXI_HOST}" == "SYS" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
MSG="Waiting for iSCSI VM's to power down"
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
echo -en "${idsCL[White]}${MSG}${idsCL[White]}${MSG_SPC}: "
# for ESXIHOST in "${PW_MAINSITEHOSTS[@]}"; do
if [ "${TEST}" != "true" ]; then
if [ "${1}" == "10.10.2.10" ] || [ "${1}" == "MAIN" ]; then
if [ "${1}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${1}" == "MAIN" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown-verify.ps1 >/dev/null 2>&1
elif [ "${1}" == "10.10.2.17" ] || [ "${1}" == "SYS" ]; then
elif [ "${1}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${1}" == "SYS" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown-verify.ps1 >/dev/null 2>&1
elif [ "${1}" == "MAINSITE" ] || [ "${1}" == "ALL" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-all-shutdown-verify.ps1 >/dev/null 2>&1
@@ -412,9 +389,9 @@ SHUTDOWN_SERVER(){
# echo -e "${idsCL[Yellow]}(TEST MODE)${idsCL[Default]}"
# fi
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
MSG="Shutting down iSCSI-PRI Server"
elif [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "SYS" ]; then
elif [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "SYS" ]; then
MSG="Shutting down iSCSI-SYS Server"
elif [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ]; then
MSG="Shutting down both iSCSI-PRI & iSCSI-SYS Servers"
@@ -422,13 +399,13 @@ SHUTDOWN_SERVER(){
c=0; MSG_SPC=''; spc1=`expr ${HC_CW} - ${#MSG}`; until [ ${c} = ${spc1} ]; do MSG_SPC="${MSG_SPC} "; ((c++)); done
echo -en "${idsCL[White]}${MSG}${MSG_SPC}: "
if [ "${TEST}" != "true" ]; then
if [ "${ESXI_HOST}" == "10.10.2.10" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 10.10.2.10 >/dev/null 2>&1 &
elif [ "${ESXI_HOST}" == "10.10.2.17" ] || [ "${ESXI_HOST}" == "SYS" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 10.10.2.17 >/dev/null 2>&1 &
if [ "${ESXI_HOST}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${ESXI_HOST}" == "MAIN" ] || [ "${ESXI_HOST}" == "CONSERVE" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${PW_ISCSI-PRI_HOST} >/dev/null 2>&1 &
elif [ "${ESXI_HOST}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${ESXI_HOST}" == "SYS" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${PW_ISCSI-SYS_HOST} >/dev/null 2>&1 &
elif [ "${ESXI_HOST}" == "MAINSITE" ] || [ "${ESXI_HOST}" == "ALL" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 10.10.2.10 >/dev/null 2>&1 &
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 10.10.2.17 >/dev/null 2>&1 &
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${PW_ISCSI-PRI_HOST} >/dev/null 2>&1 &
${PW_FOLDER}/esxi-scripts/iscsi-server-shutdown.ps1 ${PW_ISCSI-SYS_HOST} >/dev/null 2>&1 &
fi
echo -e "${idsCL[Green]}Command sent${idsCL[Default]}"
else
@@ -521,9 +498,9 @@ SHUTDOWN_SERVER(){
}
VERIFY_ISCSI_VM_DOWN(){
if [ "${1}" == "10.10.2.10" ] || [ "${1}" == "MAIN" ]; then
if [ "${1}" == "${PW_ISCSI-PRI_HOST}" ] || [ "${1}" == "MAIN" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-vm-shutdown-verify.ps1 >/dev/null 2>&1
elif [ "${1}" == "10.10.2.17" ] || [ "${1}" == "SYS" ]; then
elif [ "${1}" == "${PW_ISCSI-SYS_HOST}" ] || [ "${1}" == "SYS" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-sys-vm-shutdown-verify.ps1 >/dev/null 2>&1
elif [ "${1}" == "MAINSITE" ] || [ "${1}" == "ALL" ]; then
${PW_FOLDER}/esxi-scripts/iscsi-all-shutdown-verify.ps1 >/dev/null 2>&1
@@ -1042,9 +1019,6 @@ fi
dl|downlist) DOWNLIST;;
cooldown) COOLDOWN_SRVRM;;
cooldown-overnight) COOLDOWN_SRVRM_OVERNIGHT ${2};;
oldhelp)
echo -e "${idsCL[White]} Usage: ${idsCL[LightYellow]}[powerwall or pw]${idsCL[LightCyan]} {option}"
echo