This commit is contained in:
2025-07-13 22:02:06 -05:00
parent a5a7e1dcb2
commit bc4b996b3c
2 changed files with 13 additions and 7 deletions

View File

@@ -1,6 +1,6 @@
#!/usr/bin/env bash
PW_VERS='2.11.19-07122025'
PW_VERS='2.11.20-07132025'
noheader=' update service dailytemp confsync -r -report test '

View File

@@ -472,14 +472,18 @@ CHECKPOWER(){
OFFSITE_VOLTIN=$(echo "${upsinfo}" | grep 'input.voltage:' | sed 's/.*: //' | tr -d $'\r')
OFFSITE_VOLTOUT=$(echo "${upsinfo}" | grep 'output.voltage:' | sed 's/.*: //' | tr -d $'\r')
OFFSITE_LOAD=$(echo "${upsinfo}" | grep 'ups.load:' | sed 's/.*: //' | tr -d $'\r')
OFFSITE_WATTS=`echo "scale=2; $(echo "scale=2; ${OFFSITE_LOAD}/100" | tr -d $'\r' | bc)*$(echo "${upsinfo}" | grep 'ups.realpower.nominal:' | sed 's/.*: //')" | tr -d $'\r' | bc`
OFFSITE_AMPS=`echo "scale=2; ${OFFSITE_WATTS}/${OFFSITE_VOLTOUT}" | tr -d $'\r' | bc`
(( $(bc <<<"${OFFSITE_AMPS} < 1") )) && [[ "${OFFSITE_AMPS}" = *"."* ]] && OFFSITE_AMPS="0${OFFSITE_AMPS}"
# OFFSITE_WATTS=`echo "scale=2; $(echo "scale=2; ${OFFSITE_LOAD}/100" | tr -d $'\r' | bc)*$(echo "${upsinfo}" | grep 'ups.realpower.nominal:' | sed 's/.*: //')" | tr -d $'\r' | bc`
# OFFSITE_AMPS=`echo "scale=2; ${OFFSITE_WATTS}/${OFFSITE_VOLTOUT}" | tr -d $'\r' | bc`
# (( $(bc <<<"${OFFSITE_AMPS} < 1") )) && [[ "${OFFSITE_AMPS}" = *"."* ]] && OFFSITE_AMPS="0${OFFSITE_AMPS}"
OFFSITE_BATT_RUNTIME=$(echo "${upsinfo}" | grep 'battery.runtime:' | sed 's/.*: //' | tr -d $'\r')
OFFSITE_BATT_RUNTIME=`echo "scale=2; ${OFFSITE_BATT_RUNTIME}/60" | tr -d $'\r' | bc`
OFFSITE_BATT_VOLT=$(echo "${upsinfo}" | grep 'battery.voltage:' | sed 's/.*: //' | tr -d $'\r')
OFFSITE_BATT_CAP=$(echo "${upsinfo}" | grep 'battery.charge:' | sed 's/.*: //' | tr -d $'\r')
POWER_STRIP_DATA=$(kasa --type strip --json --host 10.2.1.234 energy)
OFFSITE_WATTS=$(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.power_mw')/1000" | tr -d $'\r' | bc -l)
OFFSITE_AMPS=$(echo $(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.current_ma')/1000" | tr -d $'\r' | bc -l))
declare -A OFFSITE_MISC
for mSENSOR in "${PW_POWERSENSOR_MISC[@]}"; do
OFFSITE_MISC[${mSENSOR}]=$(GET_TUYA_POWER ${mSENSOR})
@@ -1033,7 +1037,8 @@ OFFSITE_CHECKPOWER_SERVICE(){
OFFSITE_VOLTIN=$(echo "${upsinfo}" | grep 'input.voltage:' | sed 's/.*: //' | tr -d $'\r')
OFFSITE_LOAD=$(echo "${upsinfo}" | grep 'ups.load:' | sed 's/.*: //' | tr -d $'\r')
OFFSITE_LOAD=`echo "scale=2; ${OFFSITE_LOAD}/100" | tr -d $'\r' | bc`
OFFSITE_WATTS=`echo "scale=2; ${OFFSITE_LOAD}*$(echo "${upsinfo}" | grep 'ups.realpower.nominal:' | sed 's/.*: //')" | tr -d $'\r' | bc`
POWER_STRIP_DATA=$(kasa --type strip --json --host 10.2.1.234 energy)
OFFSITE_WATTS=$(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.power_mw')/1000" | tr -d $'\r' | bc -l)
OFFSITE_BATT_RUNTIME=$(echo "${upsinfo}" | grep 'battery.runtime:' | sed 's/.*: //' | tr -d $'\r')
OFFSITE_BATT_RUNTIME=`echo "scale=2; ${OFFSITE_BATT_RUNTIME}/60" | tr -d $'\r' | bc`
OFFSITE_BATT_CAP=$(echo "${upsinfo}" | grep 'battery.charge:' | sed 's/.*: //' | tr -d $'\r')
@@ -1325,8 +1330,9 @@ POWERLOGGER_SERVICE(){
OFFSITE_VOLTOUT=$(echo "${upsinfo}" | grep 'output.voltage:' | sed 's/.*: //' | tr -d $'\r')
OFFSITE_LOAD=$(echo "${upsinfo}" | grep 'ups.load:' | sed 's/.*: //' | tr -d $'\r')
OFFSITE_LOAD=`echo "scale=2; ${OFFSITE_LOAD}/100" | tr -d $'\r' | bc`
OFFSITE_WATTS=`echo "scale=2; ${OFFSITE_LOAD}*$(echo "${upsinfo}" | grep 'ups.realpower.nominal:' | sed 's/.*: //')" | tr -d $'\r' | bc`
OFFSITE_AMPS=`echo "scale=2; ${OFFSITE_WATTS}/${OFFSITE_VOLTOUT}" | tr -d $'\r' | bc`
POWER_STRIP_DATA=$(kasa --type strip --json --host 10.2.1.234 energy)
OFFSITE_WATTS=$(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.power_mw')/1000" | tr -d $'\r' | bc -l)
OFFSITE_AMPS=$(echo $(echo "scale=2; $(echo ${POWER_STRIP_DATA} | jq '.current_ma')/1000" | tr -d $'\r' | bc -l))
if (( $(bc <<<"${OFFSITE_WATTS} < 100") )); then
TOTAL_MISC_WATTS=0; TOTAL_MISC_AMPS=0