Update powerwall.sh

This commit is contained in:
2023-12-11 17:40:36 -06:00
parent bd825ce756
commit e6501fb772

View File

@@ -339,20 +339,20 @@ Previous Temp: ${last_temp[${SENSOR}]}${GAUGESH}"
last_temp[${SENSOR}]=1
# iDS-vMS-Offsite Fan Issue Workaround
if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ]; then
vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSORa}]} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.3 -O vq)
# vHOSTFAN=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${SENSORa}]} -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1)
if [ "${vHOSTFAN}" != "" ]; then
FanSpeed=`echo "scale=2; ${vHOSTFAN}/21200" | bc`; FanSpeed=`echo "scale=0; ${FanSpeed}*100" | bc | sed -e 's/.00//g'`
# FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g')
if [ ${FanSpeed} -lt 26 ] || [ ${FanSpeed} -gt 34 ]; then
# if [ ${FanSpeed} -ne 30 ]; then
SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} Fan Issue" "Settings fans back to normal 30%25"
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00 >/dev/null 2>&1
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0x1E >/dev/null 2>&1
fi
fi
fi
# if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ]; then
# vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSORa}]} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.3 -O vq)
# # vHOSTFAN=$(ssh -q -o ConnectTimeout=1 -o ConnectionAttempts=1 root@${PW_RACADM_ACCESS} racadm -r ${PW_HOST_IDRACS[${SENSORa}]} -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1)
# if [ "${vHOSTFAN}" != "" ]; then
# FanSpeed=`echo "scale=2; ${vHOSTFAN}/21200" | bc`; FanSpeed=`echo "scale=0; ${FanSpeed}*100" | bc | sed -e 's/.00//g'`
# # FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g')
# if [ ${FanSpeed} -lt 26 ] || [ ${FanSpeed} -gt 34 ]; then
# # if [ ${FanSpeed} -ne 30 ]; then
# SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} Fan Issue" "Settings fans back to normal 30%25"
# ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00 >/dev/null 2>&1
# ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0x1E >/dev/null 2>&1
# fi
# fi
# fi
else
([ ! "${last_temp[${SENSOR}]}" ] || (( $(bc <<< "${last_temp[${SENSOR}]} < 2") ))) && last_temp[${SENSOR}]=${temp_f}