@@ -221,13 +221,13 @@ CHECKTEMP_SERVICE(){
rm -f ${PW_TMPFOLDER}/${SENSORa}.down
fi
if [ "${PW_SENSOR_TYPE[${SENSORa}]}" == "esxi" ]; then
vHOST_TEMPNAMES=$(snmpwalk -v 1 -c public -t 2 ${vHOSTiDRACIP} .1.3.6.1.4.1.674.10892.5.4.700.20.1.8 -O vq | sed -e 's/"//g' | sed -e 's/ Temp//g')
vHOST_TEMPNAMES=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSORa}]} .1.3.6.1.4.1.674.10892.5.4.700.20.1.8 -O vq | sed -e 's/"//g' | sed -e 's/ Temp//g')
IFS=$'\n'
read -rd '' -a SENSORS_CHECK <<<"${vHOST_TEMPNAMES}"
unset IFS
[ -f ${PW_TMPFOLDER}/power.${SENSORa}.off ] && [ $(expr `date +%s` - $(stat -c %Y ${PW_TMPFOLDER}/power.${SENSORa}.off)) -ge 300 ] && rm-f ${PW_TMPFOLDER}/power.${SENSORa}.off
t=1
echo "HOST: ${PW_HOST_IDRACS[${SENSORa}]}"
# iDS-vMS-Offsite Fan Issue Workaround
if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ]; then
vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSORa}]} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.1 -O vq)
@@ -235,8 +235,8 @@ CHECKTEMP_SERVICE(){
echo "HERE: ${vHOSTFAN} - ${FanSpeed}"
if [ ${FanSpeed} -gt 92 ]; then
SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} Fan Issue" "Workaround commands sent to set the Fans at 30%25" 1
run=$(ipmitool -I lanplus -H ${vHOSTiDRACIP} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00)
run=$(ipmitool -I lanplus -H ${vHOSTiDRACIP} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0xff)
run=$(ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00)
run=$(ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0xff)
FanSpeed=30
fi
fi
@@ -312,8 +312,8 @@ CHECKTEMP_SERVICE(){
# iDS-vMS-Offsite Fan Issue Workaround
if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ] && [ ${FanSpeed} -ne 80 ]; then
SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} SERVER WARM" "Setting fan speeds to 80%25" 1
run=$(ipmitool -I lanplus -H ${vHOSTiDRACIP} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00)
run=$(ipmitool -I lanplus -H ${vHOSTiDRACIP} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0x50)
run=$(ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00)
run=$(ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0x50)
fi
fi
@@ -375,8 +375,8 @@ Previous Temp: ${last_temp[${SENSOR}]}'F"
# iDS-vMS-Offsite Fan Issue Workaround
if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ] && [ ${FanSpeed} -ne 30 ]; then
SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} Fan Issue" "Settings fans back to normal 30%25"
run=$(ipmitool -I lanplus -H ${vHOSTiDRACIP} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00)
run=$(ipmitool -I lanplus -H ${vHOSTiDRACIP} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0x1E)
run=$(ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00)
run=$(ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0x1E)
fi
fi