@@ -580,19 +580,30 @@ CHECKPOWER(){
echo -e "${idsCL[Yellow]}Offsite Power Information"
DIVIDER . yellow 75
# if [ "$(CHECK_HOST 10.2.1.100)" != "false" ]; then
OFFSITE_VOLTIN=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.4.1.3808.1.1.1.3.2.1.0 | sed 's/.*: //')
OFFSITE_VOLTIN=`echo "scale=2; ${OFFSITE_VOLTIN}/10" | bc`
OFFSITE_VOLTOUT=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.4.1.3808.1.1.1.4.2.1.0 | sed 's/.*: //')
OFFSITE_VOLTOUT=`echo "scale=2; ${OFFSITE_VOLTOUT}/10" | bc`
OFFSITE_LOAD=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.4.1.3808.1.1.1.4.2.3.0 | sed 's/.*: //')
if [ "$(CHECK_HOST 10.2.1.1)" != "false" ]; then
upsinfo=$(ssh admin@10.2.1.1 'upsc CP1500PFCLCD')
OFFSITE_VOLTIN=$(echo "${upsinfo}" | grep 'input.voltage:' | sed 's/.*: //')
OFFSITE_VOLTOUT=$(echo "${upsinfo}" | grep 'output.voltage:' | sed 's/.*: //')
OFFSITE_LOAD=$(echo "${upsinfo}" | grep 'ups.load:' | sed 's/.*: //')
OFFSITE_LOAD=`echo "scale=2; ${OFFSITE_LOAD}/100" | bc`
OFFSITE_WATTS=`echo "scale=2; ${OFFSITE_LOAD}*900" | bc`
OFFSITE_WATTS=`echo "scale=2; ${OFFSITE_LOAD}*$(echo "${upsinfo}" | grep 'ups.realpower.nominal:' | sed 's/.*: //')" | bc`
OFFSITE_AMPS=`echo "scale=2; ${OFFSITE_WATTS}/${OFFSITE_VOLTOUT}" | bc`
OFFSITE_BATT_RUNTIME=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.2.1.33.1.2.3.0 | sed 's/.*: //')
OFFSITE_BATT_CAP=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.2.1.33.1.2.4.0 | sed 's/.*: //')
OFFSITE_BATT_RUNTIME=$(echo "${upsinfo}" | grep 'battery.runtime:' | sed 's/.*: //')
OFFSITE_BATT_RUNTIME=`echo "scale=2; ${OFFSITE_BATT_RUNTIME}/60" | bc`
OFFSITE_BATT_CAP=$(echo "${upsinfo}" | grep 'battery.charge:' | sed 's/.*: //')
# fi
# OFFSITE_VOLTIN=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.4.1.3808.1.1.1.3.2.1.0 | sed 's/.*: //')
# OFFSITE_VOLTIN=`echo "scale=2; ${OFFSITE_VOLTIN}/10" | bc`
# OFFSITE_VOLTOUT=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.4.1.3808.1.1.1.4.2.1.0 | sed 's/.*: //')
# OFFSITE_VOLTOUT=`echo "scale=2; ${OFFSITE_VOLTOUT}/10" | bc`
# OFFSITE_LOAD=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.4.1.3808.1.1.1.4.2.3.0 | sed 's/.*: //')
# OFFSITE_LOAD=`echo "scale=2; ${OFFSITE_LOAD}/100" | bc`
# OFFSITE_WATTS=`echo "scale=2; ${OFFSITE_LOAD}*900" | bc`
# OFFSITE_AMPS=`echo "scale=2; ${OFFSITE_WATTS}/${OFFSITE_VOLTOUT}" | bc`
# OFFSITE_BATT_RUNTIME=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.2.1.33.1.2.3.0 | sed 's/.*: //')
# OFFSITE_BATT_CAP=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.2.1.33.1.2.4.0 | sed 's/.*: //')
fi
echo -e "${idsCL[LightCyan]}UPS Voltage In ${idsCL[Default]}: ${idsCL[Green]}${OFFSITE_VOLTIN}'Volts${idsCL[Default]}"
echo -e "${idsCL[LightCyan]}UPS Voltage Out ${idsCL[Default]}: ${idsCL[Green]}${OFFSITE_VOLTOUT}'Volts${idsCL[Default]}"
@@ -737,11 +748,17 @@ Shutting down all servers" 1
######offsite check
if [ "$(CHECK_HOST 10.2.1.100)" != "false" ]; then
OFFSITE_VOLTIN=$(snmpwalk -v 1 -c public 10.2.1.100 iso.3.6.1.4.1.3808.1.1.1.3.2.1.0 | sed 's/.*: //')
OFFSITE_VOLTIN=`echo "scale=2; ${OFFSITE_VOLTIN}/10" | bc`
OFFSITE_BATT_RUNTIME=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.2.1.33.1.2.3.0 | sed 's/.*: //')
OFFSITE_BATT_CAP=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.2.1.33.1.2.4.0 | sed 's/.*: //')
if [ "$(CHECK_HOST 10.2.1.1)" != "false" ]; then
upsinfo=$(ssh admin@10.2.1.1 'upsc CP1500PFCLCD')
OFFSITE_VOLTIN=$(echo "${upsinfo}" | grep 'input.voltage:' | sed 's/.*: //')
OFFSITE_BATT_RUNTIME=$(echo "${upsinfo}" | grep 'battery.runtime:' | sed 's/.*: //')
OFFSITE_BATT_RUNTIME=`echo "scale=2; ${OFFSITE_BATT_RUNTIME}/60" | bc`
OFFSITE_BATT_CAP=$(echo "${upsinfo}" | grep 'battery.charge:' | sed 's/.*: //')
# OFFSITE_VOLTIN=$(snmpwalk -v 1 -c public 10.2.1.100 iso.3.6.1.4.1.3808.1.1.1.3.2.1.0 | sed 's/.*: //')
# OFFSITE_VOLTIN=`echo "scale=2; ${OFFSITE_VOLTIN}/10" | bc`
# OFFSITE_BATT_RUNTIME=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.2.1.33.1.2.3.0 | sed 's/.*: //')
# OFFSITE_BATT_CAP=$(snmpwalk -t 1 -r 0 -v 1 -c public 10.2.1.100 iso.3.6.1.2.1.33.1.2.4.0 | sed 's/.*: //')
if (( $(bc <<<"${OFFSITE_VOLTIN} >= ${min_acvolt}") )); then
if [ -f ${PW_TMPFOLDER}/power.offsite.ac.low ]; then
@@ -764,8 +781,8 @@ BATT RUNTIME: ${OFFSITE_BATT_RUNTIME}'Mins" 1
touch ${PW_TMPFOLDER}/power.offsite.ac.low
fi
if [ ${OFFSITE_BATT_CAP} -le 70 ] && [ ! -f ${PW_TMPFOLDER}/power.offsite.off ]; then
SHUTDOWN_OFFSITE &
if (( $(bc <<<"${OFFSITE_BATT_CAP} <= 70") )); then
[ ! -f ${PW_TMPFOLDER}/power.offsite.off ] && SHUTDOWN_OFFSITE &
fi
fi