Update powerwall.sh

This commit is contained in:
2023-11-06 20:04:15 -06:00
parent 811d49798b
commit f8948a6b4c

View File

@@ -44,8 +44,10 @@ CHECKTEMP(){
# iDS-vMS-Offsite Fan Issue Workaround
if [ "${vHOSTiDRACIP}" == "10.2.1.21" ]; then
vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${vHOSTiDRACIP} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.1 -O vq)
FanSpeed=`echo "scale=2; ${vHOSTFAN}/21200" | bc`; FanSpeed=`echo "scale=0; ${FanSpeed}*100" | bc | sed -e 's/.00//g'`
# vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${vHOSTiDRACIP} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.1 -O vq)
# FanSpeed=`echo "scale=2; ${vHOSTFAN}/21200" | bc`; FanSpeed=`echo "scale=0; ${FanSpeed}*100" | bc | sed -e 's/.00//g'`
vHOSTFAN=$(ssh root@${PW_RACADM_ACCESS} racadm -r ${vHOSTiDRACIP} -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1)
FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g')
if [ ${FanSpeed} -gt 92 ]; then
SENDNOTICE "${vHOSTiDRACIP} Fan Issue" "Workaround commands sent to set the Fans at 30%" 1
ipmitool -I lanplus -H ${vHOSTiDRACIP} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00 >/dev/null 2>&1
@@ -231,8 +233,10 @@ CHECKTEMP_SERVICE(){
# iDS-vMS-Offsite Fan Issue Workaround
if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ]; then
vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${PW_HOST_IDRACS[${SENSORa}]} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.1 -O vq)
FanSpeed=`echo "scale=2; ${vHOSTFAN}/16561" | bc`; FanSpeed=`echo "scale=0; ${FanSpeed}*100" | bc | sed -e 's/.00//g'`
# vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${vHOSTiDRACIP} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.1 -O vq)
# FanSpeed=`echo "scale=2; ${vHOSTFAN}/21200" | bc`; FanSpeed=`echo "scale=0; ${FanSpeed}*100" | bc | sed -e 's/.00//g'`
vHOSTFAN=$(ssh root@${PW_RACADM_ACCESS} racadm -r ${vHOSTiDRACIP} -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1)
FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g')
if [ ${FanSpeed} -gt 92 ]; then
SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} Fan Issue" "Workaround commands sent to set the Fans at 30%25" 1
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00 >/dev/null 2>&1
@@ -375,10 +379,16 @@ Previous Temp: ${last_temp[${SENSOR}]}'F"
last_temp[${SENSOR}]=1
# iDS-vMS-Offsite Fan Issue Workaround
if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ] && [ ${FanSpeed} -ne 30 ]; then
SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} Fan Issue" "Settings fans back to normal 30%25"
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00 >/dev/null 2>&1
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0x1E >/dev/null 2>&1
if [ "${PW_HOST_IDRACS[${SENSORa}]}" == "10.2.1.21" ]; then
# vHOSTFAN=$(snmpwalk -v 1 -c public -t 2 ${vHOSTiDRACIP} .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.1 -O vq)
# FanSpeed=`echo "scale=2; ${vHOSTFAN}/21200" | bc`; FanSpeed=`echo "scale=0; ${FanSpeed}*100" | bc | sed -e 's/.00//g'`
vHOSTFAN=$(ssh root@${PW_RACADM_ACCESS} racadm -r ${vHOSTiDRACIP} -u ${PW_ESXI_USER} -p "'${PW_ESXI_PASS}'" getsensorinfo | grep "System Board Fan1" 2>&1)
FanSpeed=$(echo ${vHOSTFAN} | awk '/ / {print $8}' | sed -e 's/%//g')
if [ ${FanSpeed} -ne 30 ]; then
SENDNOTICE "${PW_HOST_IDRACS[${SENSORa}]} Fan Issue" "Settings fans back to normal 30%25"
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x01 0x00 >/dev/null 2>&1
ipmitool -I lanplus -H ${PW_HOST_IDRACS[${SENSORa}]} -U ${PW_ESXI_USER} -P "${PW_ESXI_PASS}" raw 0x30 0x30 0x02 0xff 0x1E >/dev/null 2>&1
fi
fi
fi
@@ -1527,7 +1537,7 @@ fi
else
if [ "${3}" = "start" ] || [ "${3}" = "" ]; then
if [ "${2}" = "temp" ]; then
SENDNOTICE "Temp Monitor Startup" "$(DAILYTEMP)" &
# SENDNOTICE "Temp Monitor Startup" "$(DAILYTEMP)" &
CHECKTEMP_SERVICE
elif [ "${2}" = "power" ]; then
CHECKPOWER_SERVICE